instrument cluster ISUZU TF SERIES 2004 Owner's Manual
Page 3322 of 4264
11A-36 IMMOBILIZER SYSTEM
NO IMMOBILIZER WARNING LAMP
Step Action Value(s) Yes No
1 Check the meter fuse for the instrument cluster
ignition feed circuit.
Is the fuse normal?
Go to Step 3
Go to Step 2
2 Replace the fuse.
Is the action complete?
Verify repair
Go to Step 3
3 1. Key position is "OFF".
2. Disconnect the meter.
3. Disconnect the engine control module (ECM).
4. Check the circuit between meter and ECM for an
open, short to round, or short to voltage.
Also, check the meter circuit for an open or short to
ground and the DLC ground circuit for an open.
Was a problem found?
Go to Step 4
Go to Step 5
4 Repair or replace the meter circuit.
Was the action complete?
Go to Step 5
5 1. Key position is "ON," engine "OFF."
2. Observe the check engine lamp.
Is the check engine lamp "ON"?
Go to Step 6
Go to Step 7
6 Repair or replace the meter.
Was the action complete?
Go to Step 7
7 1. Key position is "OFF".
2. Check the check engine lamp bulb.
Is the check engine lamp bulb normal?
Go to Step 9
Go to Step 8
8 Replace the check engine lamp bulb.
Is the action complete?
Verify repair
Go to Step 9
9 1. Key position is "OFF".
2. Connect the meter.
3. Connect the engine control module (ECM).
4. Key position is "ON".
5. Observe the check engine lamp.
Note: If a key switch is turned ON, check engine lamp
will turn on and a check engine lamp will be turned off
after a few seconds.
Is the check engine lamp "ON"?
Verify repair
Go to Step 10
10 Replace the engine control module (ECM).
IMPORTANT: The replacement ICU must be
programmed the immobilizer data by scan tool.
Was the action complete?
Verify repair