clutch LAND ROVER DISCOVERY 1995 Repair Manual

Page 458 of 873

ZF
21
REPAIR REPLACING PUMP
Service repair no - 44.32.01
1.Remove gearbox and transfer box assembly.
See LT230T Transfer Gearbox
2.Place gearbox on bench. Remove torque
converter using torque converter handles
18G1501, taking care not to damage torque
converter/oil pump housing oil seal.
3.Remove twelve bolts (inner ring pattern).
4.Remove bell housing and pump assembly from
gearbox case, discard gasket.
5.Remove eight bolts on rear of pump.
6.Screw in two bolts,diagonally opposite each
other, tap lightly using a soft headed mallet to
free pump assembly from intermediate plate.
7.Fit new pump assembly, aligning dowel with hole
in intermediate plate, press pump housing home.
8.Secure pump housing to intermediate plate
using eight hexagonal bolts. Tighten to
10 Nm.
9.Place bell housing and intermediate plate
assembly on bench, front face up. Using oil
pump rotation sleeve LST111, check that pump
gears rotate freely.
10.Before replacing intermediate plate/bell housing
assembly check that thrust washer and axial
cage are seated on A clutch housing.
11.Place new gasket and disc washer onto bell
housing and intermediate plate assembly using
a Petroleum Jelly.
12.Fit bell housing and intermediate plate assembly,
tighten twelve bolts to
46 Nm.

Page 460 of 873

ZF
1
SPECIFICATIONS, TORQUE TORQUE VALUES
NOTE: Torque wrenches should be regularly checked for accuracy to ensure that all fixings are
tightened to the correct torque.
Nm
Coupling shaft to mainshaft 42*......................................................................
Filler tube to sump 68.....................................................................................
Gear change lever to gearbox 25...................................................................
Cooler pipe adaptor to gearbox 42.................................................................
Securing screws - clutch F 10.........................................................................
Securing screw - parking pawl 10...................................................................
Securing screws - pump 10............................................................................
Intermediate plate plugs (M20) 50..................................................................
Intermediate plate plugs (M14) 40..................................................................
Bell housing mounting bolts 46.......................................................................
Governor mounting screws 10........................................................................
Extension housing bolts 23.............................................................................
Control unit mounting bolts 8.........................................................................
Sump plug 10..................................................................................................
Mounting screws for sump 8..........................................................................
Drive plate to converter 39*.............................................................................
Gearbox to engine 42.....................................................................................
Strut (threaded end) 42...................................................................................
Bottom cover to converter housing 9.............................................................
Cover - converter housing 9...........................................................................
Drive plates to crankshaft adaptor 40*............................................................
Adaptor to crankshaft 84.................................................................................
NOTE: * These bolts must have threads coated with Loctite 270 prior to assembly.
Torque values below are for all screws and bolts used except for those that are specified otherwise.
METRIC Nm
M5 6......................................................................................................
M6 9......................................................................................................
M8 25.....................................................................................................
M10 45...................................................................................................
M12 90...................................................................................................
M14 105..................................................................................................
M16 180..................................................................................................
UNC / UNF
1/4 9......................................................................................................
5/16 24...................................................................................................
3/8 39.....................................................................................................
7/16 78...................................................................................................
1/2 90.....................................................................................................
5/8 136....................................................................................................

Page 753 of 873

AIR CONDITIONING
3
DESCRIPTION AND OPERATION AIR CONDITIONING SYSTEM OPERATION
The air conditioning system provides the means of
supplying cooled and dehumidified, fresh or
recirculated air to the interior of the vehicle. The
cooling effect is obtained by blowing air through the
matrix of an evaporator unit and when required,
mixing that air with heated air by means of the heater
distribution and blend unit, to provide the conditions
required inside the vehicle. The volume of conditioned
air being supplied is controlled by a variable speed
blower.
A sealed system, charged with Refrigerant R134a,
together with a blower unit, blend unit and control
system combine to achieve the cooled air condition.
For air conditioning air distribution system.
See
HEATING AND VENTILATION, Description and
operation, Heating and ventilation unit
The air conditioning system comprises five major
units:
1.An engine-mounted compressor.
2.A condenser mounted in front of the radiator.
3.A receiver/drier unit located in front of the
condenser.
4.Thermostatic expansion valve mounted above
the evaporator.
5.An evaporator unit mounted in front of the heater
matrix.
NOTE: Vehicles fitted with rear air
conditioning have an additional
evaporator/blower motor assembly located
behind the LH rear compartment lower trim panel.
These units are interconnected by hoses and pipes
carrying Refrigerant R134a, the evaporator is linked
into the vehicle ventilation system.
Refrigeration cycle
1. Compressor
The compressor (1), belt driven from the crankshaft
pulley, pressurises and circulates the refrigerant
through the system. Mounted on the compressor, an
electro-mechanical clutch maintains the correct
temperature and pressure by engaging or disengaging
to support the system's requirements. The clutch
action is normally controlled by a thermostat located
at the evaporator (5). The compressor is of the
swashplate type having fixed displacement.Should the temperature at the evaporator (5) fall low
enough for ice to begin to form on the fins, the
thermostat disengages the clutch and also isolates the
cooling fans relays. When the temperature at the
evaporator (5) rises to the control temperature, the
clutch is re-engaged.
Should the system pressure become excessive or
drop sufficiently to cause damage to the compressor
(1) a dual pressure switch (7), located in the high
pressure line, signals the relay unit to disengage the
clutch. The compressor also has an emergency high
pressure relief valve (9) fitted.
The cooling fans are controlled by engine temperature
when the air conditioning is not switched on.
2. Condenser
From the compressor, hot high pressure vaporised
refrigerant (F1) passes to the condenser (2), which is
mounted in front of the engine coolant radiator. Ram
air(A1) passing through the condenser (2),
supplemented by 2 cooling fans (8) mounted in front
of the condenser, cools the refrigerant vapour
sufficiently to form a high pressure slightly subcooled
liquid (F2).
3. Receiver/drier
This liquid then passes to a receiver/drier (3) which
fulfils two functions. It acts as a reservoir and moisture
extractor (11).
A sight glass (10), in the high pressure line, provides a
method of determining the state of the refrigerant
without breaking into the system.
4. Expansion valve
From the receiver/drier (3) the moisture free high
pressure liquid refrigerant (F3) passes through a
thermostatic expansion valve (4). A severe pressure
drop occurs across the valve and as the refrigerant
enters the evaporator space at a temperature of
approximately -5°C it boils and vaporises.

Page 754 of 873

82AIR CONDITIONING
4
DESCRIPTION AND OPERATION 5. Evaporator
As this change of state occurs, a large amount of
latent heat is absorbed. The evaporator is therefore
cooled and as a result heat is extracted from the air
flowing across the evaporator. The air flow is
controlled by the ventilation fan which can be
operated at anyone of four speeds.
To prevent liquid passing through to the compressor,
a capillary tube (6), attached to the outlet pipe of the
evaporator (5) and connected to the thermostatic
expansion valve (4), controls the amount that the
valve opens and closes in relation to the temperature
of the low pressure high temperature refrigerant
vapour (F4) at the outlet. The atomised refrigerant
then passes through the evaporator (5). Fan blown air
(A2) passes through the matrix (A3) of the evaporator
and is cooled by absorption due to the low
temperature refrigerant passing through the
evaporator.
A thermostat is fitted in the airflow out of the
evaporator to sense the temperature of the exterior
fins. Should ice begin to form, due to a too cold
condition, it will signal to disengage the
electro-mechanical clutch on the compressor (1).
From the evaporator, low pressure slightly
superheated refrigerant (F5) passes to the
compressor to complete the cycle.AIR CONDITIONING CONTROL SYSTEM
The air conditioning control system comprises relays,
thermostat, pressure switches, and a control panel.
Inputs from outside the air conditioning system
comprise temperature information from the engine
cooling system. Together these controls, in
conjunction with the cooling fans, compressor clutch,
blower and heater distribution and blend unit enable
minimal input to maintain the required environment
inside the vehicle.
When air conditioning is not selected, air is supplied
by ram effect or blower to the areas selected by the
controls. The air mix flap on the blend unit controls the
temperature of the air being supplied. No cooled air is
available.
Selecting air conditioning provides the added facility of
cooled air available to be mixed as before. When
required a fully cold condition can be selected by
turning the temperature controls to cold, which
automatically closes the heated coolant access to the
heater matrix. Mixtures of cooled, fresh, and hot air
can be selected to give required interior environmental
conditions by selection at the control panel.
Dual pressure switch
This switch, located in the high pressure line between
the receiver drier and the expansion valve, monitors
refrigerant pressure and by means of the relay module
controls the following system functions:
1.Refrigerant pressure drops below 2.0 bar, 29
lbf/in
2(due to possible leakage), the
compressor's electro-mechanical clutch is
dis-engaged.
When pressure rises above 2.0 bar, 29 lbf/in
2the
compressor's clutch is re-engaged.
2.Refrigerant pressure rises above 32 bar, 455
lbf/in
2(due to possible blockage), even with
cooling fan operation, the compressor's
electro-mechanical clutch is dis-engaged.
When the pressure drops below 26 bar, 375
lbf/in
2the compressor clutch is re-engaged.

Page 756 of 873

AIR CONDITIONING
1
FAULT DIAGNOSIS AIR CONDITIONING FAULTS
FAULT CAUSE REMEDY
1. Incorrect voltage. 1. Check voltage.
A.2. Open or defective fuse or relay. 2. Check and replace as necessary.
BLOWER3. Loose wire connection including 3. Check system wires; tighten
MOTORground. all connections.
INOPERATIVE4. Switch open or defective. 4. Replace switch.
OR SLOW5. Tight, worn, or burnt motor 5. Replace motor.
RUNNINGbearings.
6. Open rotor windings. 6. Replace motor.
7. Worn motor brushes. 7. Replace motor.
8. Shaft binding-blade misaligned. 8. Check alignment. Repair or replace
as necessary.
9. Defective resistors 9. Rectify or replace.
1. Incorrect voltage. 1. Check voltage.
2. Open or defective fuse or relay. 2. Check and replace as necessary.
B.3. Defective thermostat control or 3. Replace thermostat or
COMPRESSORpressure switch. pressure switch.
CLUTCH4. Shorted or open field coil. 4. Replace coil.
INOPERATIVE5. Bearing seized (clutch will not 5. Replace clutch pulley assembly.
disengage).
6. Refrigeration circuit problem causing
heavy load and excessive drive
torque.6. Check and rectify.
1. Incorrect alignment. 1. Check alignment; repair as
necessary.
2. Loose belt. 2. Adjust to proper tension.
C.3. Compressor not mounted securely. 3. Repair as necessary.
COMPRESSOR4. Bearing in clutch-pulley 4. Remove clutch and replace
CLUTCHassembly not pressed in. clutch pulley assembly.
NOISY5. Low voltage to clutch. 5. Check connections and voltage.
6. Clutch will not spin freely. 6. Refer to B5 above.
7. Oil on clutch face. 7. Check compressor seals for leaks.
8. Slipping clutch. 8. Refer to C5 above. Then check air
gap.
9. Overloaded or locked compressor. 9. Repair or replace compressor.
10. Icing. 10. Check for suction line frosting.
Replace expansion valve if
necessary.
Replace receiver/drier if necessary.
D.1. Motor and/or blades improperly 1. Check mountings, adjust as
CONDENSERmounted. necessary.
VIBRATION2. Foreign matter build-up on 2. Clean blades with a suitable
blades. non-inflammable cleaner.
3. Excessive wear of motor bearings. 3. Replace motor.

Page 757 of 873

82AIR CONDITIONING
2
FAULT DIAGNOSIS REFRIGERATION SYSTEM FAULTS
For any refrigeration system to function properly all
components must be in good working order. The unit
cooling cycle and the relationship between air
discharge temperature and ambient temperature and
the pressures at the compressor can help to
determine proper operation of the system.
The length of any cooling cycle is determined by such
factors as ambient temperature and humidity,
thermostat setting, compressor speed and air leakage
into the cooled area, etc. With these factors constant,
any sudden increase in the length of the cooling cycle
would be indicative of abnormal operation of the air
conditioner.
The low and high side pressures at the compressor
will vary with changing ambient temperature, humidity,
in-car temperature and altitude.
The following items should be checked before
operating the system:
1.Compressor drive belt tension.
2.Compressor magnetic clutch operation.
3.Condenser fan operation.
4.Condenser fins, dirt will cause poor cooling and
higher operating temperatures.The following conditions should be checked after
operating the system for several minutes:
1.All high pressure lines and components should
be hot to the touch.
2.All low pressure lines should be cool to the
touch.
3.Inlet and outlet temperatures at the receiver/drier
should be at the same temperature (warm). Any
very noticeable temperature difference indicates
a blocked receiver/drier.
4.Heavy frost on the inlet to the expansion valve
may indicate a defective valve or moisture in the
system.
5.Evaporation air temperature will vary with
ambient temperature and humidity. As humidity
increases the outlet temperature will be higher.

Page 759 of 873

82AIR CONDITIONING
4
FAULT DIAGNOSISFAULT CAUSE REMEDY
E.
NOISY
EXPANSION
VALVE
(steady hissing)1. Low refrigerant charge; evident by
bubbles in sight glass.1. Leak test. Repair or replace
components as required.
F.1. Expansion valve not operating 1. Refer to C-2, C-3, D-1
INSUFFICIENTproperly. and E.
COOLING2. Low refrigerant charge-evident 2. Refer to B-1 and E.
by bubbles in sight glass.
3. Compressor not pumping. 3. Refer to B-2 and B-3
G.1. Belt tension. 1. Adjust belt tension.
COMPRESSOR2. Excessive head pressure. 2. Refer to A-1 through
BELTA-4 and C-6.
SLIPPING3. Incorrect alignment of pulleys 3. Repair as needed.
or worn belt not riding properly.
4. Nicked or broken pulley. 4. Replace as needed.
5. Seized compressor. 5. Replace compressor.
1. Loose or missing mounting bolts. 1. Repair as necessary.
2. Broken mounting bracket. 2. Replace bracket.
3. Loose flywheel or clutch 3. Repair as necessary.
retaining bolt.
H.4. Rough idler pulley bearing. 4. Replace bearing.
ENGINE5. Bent, loose, or improperly 5. Repair as necessary.
NOISEmounted engine drive pulley.
AND/OR6. Defective compressor bearing. 6. Replace bearing.
VIBRATION7. Insecure mountings of 7. Repair as necessary.
accessories; generator, power
steering, air filter, etc.
8. Excessive head pressure. 8. Refer to A-1, A-2, A-3
A-4 and C-6.
9. Incorrect compressor oil level. 9. Refer to compressor Oil
Level Check.
HEATER AND AIR CONDITIONING - CIRCUIT
DIAGRAMS
1.For details of heating and air conditioning
electrics
See Electrical Trouble Shooting
Manual.

Page 761 of 873

82AIR CONDITIONING
2
ADJUSTMENT SERVICING PRECAUTIONS
Care must be taken when handling refrigeration
system components. Units must not be lifted by their
hoses, pipes or capillary lines. Hoses and lines must
not be subjected to any twist or stress. Ensure that
hoses are positioned in their correct run before fully
tightening the couplings, and ensure that all clips and
supports are used. Torque wrenches of the correct
type must be used when tightening refrigerant
connections to the stated value. An additional wrench
must be used to hold the union to prevent twisting of
the pipe.
Before connecting any hose or pipe ensure that
refrigerant oil is applied to the seat of the new '0' ring
but not to the threads.
Check the oil trap for the amount of oil lost.
All protective plugs on components must be left in
place until immediately prior to connection.
The receiver/drier contains desiccant which absorbs
moisture. It must be positively sealed at all times.
CAUTION: Whenever the refrigerant
system is opened, the receiver/drier must
be renewed immediately before evacuating
and recharging the system.
Use alcohol and a clean cloth to clean dirty
connections.
Ensure that all new parts fitted are marked for use
withR134a.
Refrigerant oil
Use the approved refrigerant lubricating oil:
Nippon Denso ND-OIL 8
Unipart R134a ND-OIL8
CAUTION: Do not use any other type of
refrigerant oil.
Refrigerant oil easily absorbs water and must not be
stored for long periods. Do not pour unused oil back
into the container.
When renewing system components, add the
following quantities of refrigerant oil:
Condenser 40ml..........................................................
Evaporator 80ml..........................................................
Pipe or hose 20ml........................................................
Receiver/drier 20ml......................................................
Total of refrigerant oil in system = 180ml = 6.3 Fl
ozA new compressor is sealed and pressurised with
Nitrogen gas, slowly release the sealing cap, gas
pressure should be heard to release as the seal is
broken.
NOTE: A new compressor should always
have its sealing caps in place and must
not be removed until immediately prior to
fitting
Fitting a new compressor
A new compressor is supplied with an oil fill (X) of:
180ml
A calculated quantity of oil must be drained from a
new compressor before fitting.
To calculate the quantity of oil to be drained:
1.Remove sealing plugs from the OLD compressor
2.Invert compressor and gravity drain oil into
measuring cylinder. Rotating the compressor
clutch plate will assist complete draining.
3.Note the quantity of oil drained (Y).
4.Calculate the quantity (Q) of oil to be drained
from the NEW compressor using the following
formula:
X - (Y + 20ml) = Q
Rapid refrigerant discharge
When the air conditioning system is involved in
accident damage and the circuit is punctured, the
refrigerant is discharged rapidly. The rapid discharged
of refrigerant will also result in the loss of most of the
oil from the system. The compressor must be
removed and all the remaining oil in the compressor
drained and refilled as follows:
1.Gravity drain all the oil, assist by rotating the
clutch plate (not the pulley).
2.Refill the compressor with the following amount
of new refrigerant oil:
130ml
3.Plug the inlet and outlet ports.

Page 763 of 873

82AIR CONDITIONING
4
ADJUSTMENT Evacuation and recharging
1.Add refrigerant oil to compressor if necessary.
2.Renew the receiver/drier.
CAUTION: When a major repair has been
carried out, a leak test should be carried
out using inert gas.
3.Connect a Refrigerant Station to the high and
low pressure servicing connections.
CAUTION: Whenever the refrigerant
system is opened, the receiver/drier must
be renewed immediately before evacuating
and recharging the system.
4.Operate the refrigerant evacuation system
according to the manufacturer's instructions.
NOTE: If the vacuum reading is below
700mmHg after 15 minutes, suspect a leak
in the system. Partially recharge the
system and check for leaks using an electronic
leak tester. Check suction lines first, then run the
compressor for 5 minutes and then check the high
pressure lines.
CAUTION: The system must be evacuated
immediately before recharging
commences. Delay between evacuation
and recharging is not permitted.
5.Operate the refrigerant recharging system
according to the manufacturer's instructions:-
Refrigerant required to charge system:
Without rear air conditioning = 0.90kg (32 fl/oz)
With rear air conditioning = 1.15kg (40 fl/oz)
6.If the full charge has not been accepted by the
system, start the engine and run it at 1500
rev/min for a minimum of 2 minutes.
Switch on the air conditioning system, open the
car windows, set the temperature control to cold
and switch the blower to maximum speed.
7.Consult Refrigerant Station Manual for correct
procedure to complete the charge.
8.Carry out the air conditioning system
performance test.LEAK TEST SYSTEM
The following instructions refer to an electronic type
Refrigerant Leak Detector for use with R134a, which
are the safest and most sensitive.
CAUTION: When a major repair has been
carried out, a leak test should be carried
out using an inert gas (see below).
1.Place the vehicle in a well ventilated area but
free from draughts, as leakage from the system
could be dissipated without detection.
2.Follow the instructions issued by the
manufacturer of the particular leak detector
being used.
3.Commence searching for leaks by passing the
detector probe around all joints and components,
refrigerant gas is heavier than air.
4.Insert the probe into an air outlet of the
evaporator or into the evaporator drain tube.
Switch the air conditioning blower on and off at
intervals of ten seconds. Any leaking refrigerant
will be gathered in by the blower and detected.
5.Insert the probe between the magnetic clutch
and compressor to check the shaft seal for
leaks.
6.Check all service valve connections, valve plate,
head and base plate joints and back seal plate.
7.Check the condenser for leaks at the pipe
unions.
8.If any leaks are found, the system must be
discharged before rectification.
9.Rectify any leaks and recheck for leaks during
evacuation prior to charging.
Leak test using inert gas
Use Nitrogen or Helium gas.
1.Connect gas line to recharging station.
2.Pressurise system to 3 bar.
3.Carry out leak test as above.

Page 765 of 873

82AIR CONDITIONING
6
ADJUSTMENT SYSTEM TEST
1.Place the vehicle in a ventilated, shaded area
free from excessive draught, with the doors and
windows open.
2.Check that the surface of the condenser is not
restricted with dirt, leaves, flies, etc. Do not
neglect to check the surface between the
condenser and the radiator. Clean as necessary.
3.Switch on the ignition and the air conditioner air
flow control. Check that the blower is operating
efficiently at low, medium and high speeds.
Switch off the blower and the ignition.
4.Check that the evaporator condensate drain
tubes are open and clear.
5.Check the tension of the compressor driving belt,
and adjust if necessary.
6.Inspect all connections for the presence of
refrigerant oil. If oil is evident, check for leaks,
and repair as necessary.
NOTE: The compressor oil is soluble in
Refrigerant R134a and is deposited when
the refrigerant evaporates from a leak.
7.Start the engine.
8.Set the temperature controls to cold and switch
the air conditioner blower control on and off
several times, checking that the magnetic clutch
on the compressor engages and releases each
time.9.With the temperature control at maximum
cooling and the blower control at high speed,
warm up the engine and fast idle at 1000
rev/min. Check the sight glass for bubbles or
foam. The sight glass should be generally clear
after five minutes running, occasional bubbles
being acceptable. Continuous bubbles may
appear in a serviceable system on a cool day, or
if there is insufficient air flow over the condenser
at a high ambient temperature.
10.Repeat at 1800 rev/min.
11.Gradually increase the engine speed to the high
range, and check the sight glass at intervals.
12.Check for frosting on the service valves.
13.Check the high pressure hoses and connections
by hand for varying temperature. Low
temperature indicates a restriction or blockage at
that point.
14.Switch off the air conditioning blower and stop
the engine.
15.If the air conditioning equipment is still not
satisfactory, carry out a pressure test as
previously described in this section.
COMPRESSOR DRIVE BELT
Service repair no - 82.10.01.
Tdi -
See ENGINE, Repair, Compressor drive belt
V8i and MpiSee ENGINE, Repair, Drive belt

Page:   < prev 1-10 ... 21-30 31-40 41-50 51-60 61-70 71-80 next >