Relay box MITSUBISHI 380 2005 User Guide
Page 594 of 1500
CENTRALISED JUNCTION
CIRCUIT DIAGRAMS90-17
CENTRALISED RELAY
NOTE: The triangle mark on the relay housing should face that on the relay box.CONNECTOR NO. NAME CONNECTOR NO. NAME
A-05X Fog lamp relay A-16X
A-06X Horn relay B-11X
A-07XB-12X
A-08XB-13X
A-09XB-14X
A-10X Fan control relay B-15X
A-11X Front-ECU B-16X A/T control relay
A-12X Front-ECU B-17X
MPI relay
A-15X
B-18X A/C compressor clutch relay
Page 780 of 1500
AUTO A/C DIAGNOSIS
HEATER, AIR CONDITIONING AND VENTILATION55-79
STEP 8. Measure the voltage at A/C compressor assembly
connector B-28.
(1) Disconnect A/C compressor assembly connector B-28 and
measure the voltage at the relay box side.
(2) Disconnect powertrain control module connector B-20 and
ground harness side terminal No.6.
(3) Turn the ignition switch to the "ON" position.
(4) A/C compressor assembly connector B-28 terminal 1 and
ground.
The measured value should be approximately 12 volts
(battery positive voltage).
Q: Is the measured voltage approx. 12 volts?
YES : Go to Step 15.
NO : Go to Step 9.
Page 781 of 1500
AUTO A/C DIAGNOSIS
HEATER, AIR CONDITIONING AND VENTILATION55-80
STEP 9. Measure the voltage at A/C compressor clutch
relay connector B-18X.
The top and bottom of the A/C compressor connector are
difficult to identify. Prior to inspection, confirm the triangle
mark on the relay box.
(1) Disconnect A/C compressor connector B-18X and measure
the voltage at the relay box side.
(2) Turn the ignition switch to the "ON" position.
(3) Measure the voltage between terminal 2 and ground.
The measured value should be approximately 12 volts
(battery positive voltage).
Q: Is the measured voltage approx. 12 volts?
YES : Go to Step 11.
NO : Go to Step 10.
STEP 10. Check the wiring harness between A/C
compressor clutch relay connector B-18X (terminal 2) and
the ignition switch (IG2).
Page 783 of 1500
AUTO A/C DIAGNOSIS
HEATER, AIR CONDITIONING AND VENTILATION55-82
STEP 11. Measure the voltage at A/C compressor clutch
relay connector B-18X.
The top and bottom of the A/C compressor connector are
difficult to identify. Prior to inspection, confirm the triangle
mark on the relay box.
(1) Disconnect A/C compressor connector B-18X and measure
the voltage at the wiring harness side.
(2) Measure the voltage between terminal 1 and ground.
The measured value should be approximately 12 volts
(battery positive voltage).
Q: Is the measured voltage approx. 12 volts?
YES : Go to Step 13.
NO : Go to Step 12.
STEP 12. Check the wiring harness between A/C
compressor clutch relay connector B-18X (terminal 1) and
the battery.
Page 786 of 1500
AUTO A/C DIAGNOSIS
HEATER, AIR CONDITIONING AND VENTILATION55-85
STEP 16. Measure the voltage at A/C-ECU connector C-15.
(1) Disconnect A/C-ECU connector C-15 and measure the
voltage at the relay box side.
(2) Disconnect powertrain control module connector B-20 and
ground harness side terminal No.6.
(3) Turn the ignition switch to the "ON" position.
(4) Measure the voltage between A/C-ECU connector C-15
terminal No.10 and ground.
The measured value should be approximately 12 volts
(battery positive voltage).
Q: Does the measured voltage correspond with this range?
YES : Go to Step 18.
NO : Go to Step 17.
Page 922 of 1500
ENGINE COOLING DIAGNOSIS
ENGINE COOLING14-7
STEP 3. Check the fusible link No.2.
Q: Is the fusible link No.2 in good condition?
YES : Go to Step 4.
NO : Replace the fusible link No.2. Then go to Step 24.
STEP 4. Measure the power supply voltage at fan control
relay connector A-10X.
(1) Disconnect fan control relay connector A-10X (remove the
fan control relay) and measure relay box side connector.
(2) Turn the ignition switch to the "ON" position.
(3) Measure the voltage between fan control relay connector
A-10X terminal 4 and body earth.
The voltage should measure system voltage.
(4) Turn the ignition switch to the "LOCK" (OFF) position.
(5) Connect fan control relay connector A-10X (install the fan
control relay).
Q: Is the measured voltage system voltage?
YES : Go to Step 7.
NO : Go to Step 5.
Page 923 of 1500
ENGINE COOLING DIAGNOSIS
ENGINE COOLING14-8
STEP 5. Check the fan control relay connector A-10X.
Q: Is the connector in good condition?
YES : Go to Step 6.
NO : Repair the connector or replace the relay box. Then
go to Step 24.
STEP 6. Check the harness wire between fusible link No.2
and fan control relay connector A-10X terminal 4.
Q: Is the harness wire in good condition?
YES : An intermittent malfunction is suspected (Refer to
GROUP 00 - How to use troubleshooting 00-7).
NO : Repair the damaged harness wire. Then go to Step
24.
STEP 7. Check the fan control relay.
Refer to 14-31.
Q: Is the fan control relay in good condition?
YES : Go to Step 8.
NO : Replace the fan control relay. Then go to Step 24.
Page 924 of 1500
ENGINE COOLING DIAGNOSIS
ENGINE COOLING14-9
STEP 8. Check the fan control relay connector A-10X.
Q: Is the connector in good condition?
YES : Go to Step 9.
NO : Repair the connector or replace the relay box. Then
go to Step 24.
STEP 9. Check the harness wire between fan control relay
connector A-10X terminal 2 and fan controller connector
A-24 terminal 3.
Q: Is the harness wire in good condition?
YES : Go to Step 10.
NO : Repair the damaged harness wire. Then go to Step
24.
Page 925 of 1500
ENGINE COOLING DIAGNOSIS
ENGINE COOLING14-10
STEP 10. Measure the terminal voltage at fan control relay
connector A-10X.
(1) Disconnect fan control relay connector A-10X (remove the
fan control relay) and measure relay box side connector.
(2) Turn the ignition switch to the "ON" position.
(3) Measure the voltage between fan control relay connector
A-10X terminal 3 and body earth.
The voltage should measure system voltage.
(4) Turn the ignition switch to the "LOCK" (OFF) position.
(5) Connect fan control relay connector A-10X (install the fan
control relay).
Q: Is the measured voltage system voltage?
YES : Go to Step 13.
NO : Go to Step 11.
Page 928 of 1500
ENGINE COOLING DIAGNOSIS
ENGINE COOLING14-13
STEP 13. Check the continuity between fan control relay
connector A-10X and body earth.
(1) Disconnect fan control relay connector A-10X (remove the
fan control relay) and measure relay box side connector.
(2) Measure the resistance between fan control relay connector
A-10X terminal 1 and body earth.
Continuity exists.
(3) Connect fan control relay connector A-10X (install the fan
control relay).
Q: Does the continuity exists?
YES : An intermittent malfunction is suspected (Refer to
00-7).
NO : Go to Step 14.
STEP 14. Check the fan control relay connector A-10X.
Q: Is the connector in good condition?
YES : Go to Step 15.
NO : Repair the connector or replace the relay box. Then
go to Step 24.