4. CHECK DOOR LOCK SWITCH CIRCUIT
1. Disconnect BCM.
2. Check continuity between BCM connector M19 (A) terminal 45 and main power window and door lock/
unlock switch connector D8 (B) terminal 18 or power window and door lock/unlock switch RH connector
D105 (C) terminal 1.
3. Check continuity between BCM connector M19 terminal 45 and
ground.
4. Check continuity between BCM connector M19 (A) terminal 46 and main power window and door lock/
unlock switch LH connector D7 (B) terminal 6 or power window and door lock/unlock switch RH connector
D105 (C) terminal 2.
5. Check continuity between BCM connector M19 terminal 46 and
ground.
OK or NG
OK >> Replace BCM. Refer to BCS-25, "Removal and Installa-
tion of BCM" .
NG >> Repair or replace harness.1 - 45 : Continuity should exist.
18 - 45 : Continuity should exist.
45 - Ground : Continuity should not exist.
WIIA1110E
2 - 46 : Continuity should exist.
6 - 46 : Continuity should exist.
46 - Ground : Continuity should not exist.
W I I A 1111E
Page 537 of 2896
BL-48
POWER DOOR LOCK SYSTEM
Revision: June 20062007 Versa
Front Door Lock Assembly LH (Actuator) CheckEIS009CA
1. CHECK FRONT DOOR LOCK ASSEMBLY LH (ACTUATOR) HARNESS
1. Turn ignition switch OFF.
2. Disconnect BCM and front door lock assembly LH (actuator).
3. Check continuity between BCM connector (A) M20 terminals 59,
65 and front door lock assembly LH (actuator) connector (B) D3
terminals 2, 3.
4. Check continuity between BCM connector (A) M20 terminals 59,
65 and body ground.
OK or NG
OK >> GO TO 2.
NG >> Repair or replace harness.
2. CHECK FRONT DOOR LOCK ASSEMBLY LH SIGNAL
1. Reconnect BCM.
2. Check voltage between BCM connector M20 terminals 59, 65
and ground.
OK or NG
OK >> Replace front door lock assembly LH (actuator). Refer to BL-169, "Removal and Installation" .
NG >> Replace BCM. Refer to BCS-25, "
Removal and Installation of BCM" .
Connector Terminal Connector Terminal Continuity
A: M2059
B: D32Yes
65 3 Yes
Connector Terminals Continuity
A: M2059
GroundNo
65 No
LIIA2525E
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (-)
M2059
GroundMain power window and
door lock/unlock switch
is turned to UNLOCK0 → Battery voltage
65Main power window and
door lock/unlock switch
is turned to LOCK0 → Battery voltage
LIIA1355E
Page 538 of 2896
POWER DOOR LOCK SYSTEM
BL-49
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
Door Lock Actuator Check (Front RH and Rear LH/RH)EIS009CB
1. CHECK DOOR LOCK ACTUATOR HARNESS
NOTE:
For models with Intelligent Key, insure that passenger select unlock relay remains connected during this test.
1. Turn ignition switch OFF.
2. Disconnect BCM and each door lock actuator.
3. Check continuity between BCM connector (A) M20 terminals 65,
66 and front door lock actuator RH connector (B) D114, rear
door lock actuator RH connector (B) D305, rear door lock actua-
tor LH connector (C) D205 terminals 2, 3.
4. Check continuity between BCM connector (A) M20 terminals 65,
66 and body ground.
OK or NG
OK >> GO TO 2.
NG >> Check the following:
Without Intelligent Key: Repair or replace harness.
With Intelligent Key: For front doors, repair or replace harness.
With Intelligent Key: For rear door, repair or replace harness or passenger select unlock relay.
2. CHECK DOOR LOCK ACTUATOR SIGNAL
1. Reconnect BCM.
2. Check voltage between BCM connector M20 terminals 65, 66
and ground.
OK or NG
OK >> Replace front door lock assembly RH or rear door lock actuator LH/RH. Refer to BL-169,
"Removal and Installation" or BL-172, "Removal and Installation" .
NG >> Replace BCM. Refer to BCS-25, "
Removal and Installation of BCM" .
Connector Terminal Connector Terminal Continuity
A: M2065 B: D114
C: D205
D: D3053Yes
66 2 Yes
Connector Terminals Continuity
A: M2065
GroundNo
66 No
LIIA2526E
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (-)
M2065
GroundMain power window and
door lock/unlock switch is
turned to UNLOCK0 → Battery voltage
66Main power window and
door lock/unlock switch is
turned to LOCK0 → Battery voltage
LIIA1357E
Page 550 of 2896
REMOTE KEYLESS ENTRY SYSTEM
BL-61
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
Terminals and Reference Values for BCMEIS0091E
Refer to BCS-12, "Terminals and Reference Values for BCM" .
How to Perform Trouble DiagnosesEIS00A3F
1. Confirm the symptom or customer complaint.
2. Understand operation, description and function description. Refer to BL-55, "
System Description" .
3. Perform the Preliminary Check. Refer to LT- 1 2 , "
Preliminary Check" .
4. Check symptom and repair or replace the component.
5. Does the remote keyless entry system operate normally? If YES, GO TO 6. If NO, GO TO 4.
6. INSPECTION END
Preliminary CheckEIS00A3G
CHECK BCM CONFIGURATION
1. CHECK BCM CONFIGURATION
Confirm BCM configuration for "KEYLESS ENTRY" is set to "WITH". Refer to BCS-19, "
READ CONFIGURA-
TION PROCEDURE" .
OK or NG
OK >> Refer to BL-64, "Work Flow" .
NG >> Change BCM configuration for "KEYLESS ENTRY" to "WITH". Refer to BCS-21, "
WRITE CON-
FIGURATION PROCEDURE" .
CONSULT-II Function (BCM)EIS0091F
CONSULT-II can display each diagnostic item using the diagnostic test modes shown following.
CONSULT-II START PROCEDURE
Refer to GI-38, "CONSULT-II Start Procedure" .
CONSULT-II APPLICATION ITEMS
Work Support
BCM
diagnostic test itemDiagnostic mode Description
Inspection by partWORK SUPPORTSupports inspections and adjustments. Commands are transmitted to the
BCM for setting the status suitable for required operation, input/output sig-
nals are received from the BCM and received date is displayed.
DATA MONITOR Displays BCM input/output data in real time.
ACTIVE TESTOperation of electrical loads can be checked by sending drive signal to
them.
SELF-DIAG RESULTS Displays BCM self-diagnosis results.
CAN DIAG SUPPORT MNTRThe result of transmit/receive diagnosis of CAN communication can be
read.
ECU PART NUMBER BCM part number can be read.
CONFIGURATION Performs BCM configuration read/write functions.
Test Item Description
REMO CONT ID REGIST Keyfob ID code can be registered.
REMO CONT ID ERASER Keyfob ID code can be erased.
REMO CONT ID CONFIR It can be checked whether keyfob ID code is registered or not in this mode.
PANIC ALRM SETPanic alarm operation mode can be changed in this mode. The operation mode will be
changed when “CURRENT SETTING” on CONSULT-II screen is touched.
HAZARD LAMP SETHazard reminder mode can be changed in this mode. The hazard reminder mode will be
changed when “CURRENT SETTING” on CONSULT-II screen is touched.
Page 553 of 2896
BL-64
REMOTE KEYLESS ENTRY SYSTEM
Revision: June 20062007 Versa
Work FlowEIS0091G
1. Check the symptom and customer's requests.
2. Understand outline of system. Refer to BL-55, "
System Description" .
3. Confirm that power door lock system operates normally.
Refer to BL-23, "
POWER DOOR LOCK SYSTEM" .
4. Repair or replace any malfunctioning parts.
Refer to BL-64, "
Trouble Diagnosis Symptom Chart" .
5. Does remote keyless entry system operate normally? If Yes, GO TO 6. If No, GO TO 4.
6. INSPECTION END
Trouble Diagnosis Symptom ChartEIS0091H
NOTE:
Always check the “Work Flow” before troubleshooting. Refer to BL-64, "Work Flow" .
Always check keyfob battery before replacing keyfob.
Symptom Diagnoses/service procedureReference
page
All function of remote keyless entry system do not
operate.1. Check key switch.BL-70
2. Check keyfob battery and function.
NOTE:
If the result of keyfob function check with CONSULT-II is OK, key-
fob is not malfunctioning.BL-66
3. Check remote keyless entry receiver.BL-73
4. Refer to ID Code Entry Procedure.BL-76
5. Replace BCM.BCS-25
The new ID of keyfob cannot be entered.1. Check keyfob battery and function.
NOTE:
If the result of keyfob function check with CONSULT-II is OK, key-
fob is not malfunctioning.BL-662. Check key switch.BL-70
3. Check door switch.BL-68
4. Check ACC switch.BL-67
5. Replace keyfob. Refer to ID Code Entry Procedure.BL-76
6. Replace BCM.BCS-25
Door lock does not function with keyfob.
(Power door lock system is “OK”.)1. Check keyfob function. (Lock)
NOTE:
If the result of keyfob function check with CONSULT-II is OK, key-
fob is not malfunctioning.BL-75
2. Replace keyfob. Refer to ID Code Entry Procedure.BL-76
3. Check door switch.BL-68
4. Replace BCM.BCS-25
Door unlock does not function with keyfob
(Power door lock system is “ON”)1. Check keyfob function. (Unlock)BL-75
2. Replace keyfob. Refer to ID Code Entry Procedure.
NOTE:
If the result of keyfob function check with CONSULT-II is OK, key-
fob is not malfunctioning.BL-76
3. Replace BCM.BCS-25
Hazard reminder does not activate properly when
pressing lock or unlock button of keyfob.1. Check hazard reminder mode.*
*: Hazard reminder mode can be changed.
First check the hazard reminder setting.BL-61
2. Check hazard function.BL-71
3. Replace BCM.BCS-25
Page 554 of 2896
REMOTE KEYLESS ENTRY SYSTEM
BL-65
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
Panic alarm does not activate when panic alarm
button is continuously pressed.1. Check panic alarm mode.*
*: Panic alarm mode can be changed.
First check the panic alarm setting.BL-61
2. Check keyfob battery and function.
NOTE:
If the result of keyfob function check with CONSULT-II is OK, key-
fob is not malfunctioning.BL-66
3. Check horn function.BL-71
4. Check key switch.BL-70
5. Replace keyfob. Refer to ID Code Entry Procedure.BL-76
6. Replace BCM.BCS-25
Auto door lock operation does not activate properly.
(All other remote keyless entry system functions are
OK.)1. Check auto door lock operation mode.*
*: Auto door lock operation mode can be changed.
First check the auto door lock operation setting.BL-61
2. Replace BCM.BCS-25
Interior lamp operation does not activate properly.1. Check interior lamp operation.BL-722. Replace BCM.BCS-25
Symptom Diagnoses/service procedureReference
page
Page 560 of 2896
REMOTE KEYLESS ENTRY SYSTEM
BL-71
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
2. CHECK KEY SWITCH
1. Turn ignition switch OFF.
2. Disconnect key switch and key lock solenoid connector.
3. Check key switch.
OK or NG
OK >> Check the following.
10A fuse [No. 14, located in fuse block (J/B)]
Harness for open or short between key switch and
fuse
Harness for open or short between BCM and key
switch
NG >> Replace key switch and key lock solenoid.
Hazard Function CheckEIS0091M
1. CHECK HAZARD WARNING LAMP
Does hazard warning lamp flash with hazard switch?
OK or NG
OK >> Hazard warning lamp circuit is OK.
NG >> Check hazard circuit. Refer to LT- 5 1 , "
TURN SIGNAL AND HAZARD WARNING LAMPS" .
Horn Function CheckEIS0091N
First perform the “SELF-DIAG RESULTS” in “BCM” with CONSULT-II, then perform the trouble diagnosis of
malfunction system indicated “SELF-DIAG RESULTS” of “BCM”. Refer to BCS-18, "
CAN Communication
Inspection Using CONSULT-II (Self-Diagnosis)" .
1. CHECK HORN FUNCTION
Does horn sound with horn switch?
OK or NG
OK >> GO TO 2.
NG >> Check horn circuit. Refer to WW-46, "
HORN" .
2. CHECK IPDM E/R INPUT SIGNAL
Check voltage between IPDM E/R connector and ground.
OK or NG
OK >> Replace IPDM E/R. Refer to PG-29, "Removal and
Installation of IPDM E/R"
NG >> GO TO 3.
Terminals Condition Continuity
1 – 2Key is inserted. Yes
Key is removed. No
PIIB6411E
Terminals
Voltage (V)
(Approx.) (+)
(–)
IPDM E/R connector Terminal
E46 45 Ground Battery voltage
WIIA1251E
Page 561 of 2896
BL-72
REMOTE KEYLESS ENTRY SYSTEM
Revision: June 20062007 Versa
3. CHECK HORN RELAY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R and horn relay connector.
3. Check continuity between IPDM E/R harness connector and
horn relay harness connector.
4. Check continuity between IPDM E/R harness connector and
ground.
OK or NG
OK >> Check condition of harness and connector.
NG >> Repair or replace harness.
Interior Lamp and Ignition Keyhole Illumination Function CheckEIS0091O
1. CHECK INTERIOR LAMP AND IGNITION KEYHOLE ILLUMINATION FUNCTION
When map lamp switch is in “DOOR” position, open the front door (LH or RH).
Does interior lamp illuminate?
YES >> Replace BCM. Refer to BCS-25, "Removal and Installation of BCM" .
NO >> Check interior lamp circuit. Refer to LT- 9 1 , "
INTERIOR ROOM LAMP" .
AB
Continuity
IPDM E/R
connectorTe r m i n a lHorn relay
connectorTe r m i n a l
E46 45 H-1 1 Yes
A
GroundContinuity
IPDM E/R connector Terminal
E46 45 No
WIIA1252E
Page 563 of 2896
BL-74
REMOTE KEYLESS ENTRY SYSTEM
Revision: June 20062007 Versa
3. CHECK REMOTE KEYLESS ENTRY RECEIVER POWER SUPPLY CIRCUIT
1. Disconnect BCM connector.
2. Check continuity between BCM connector (A) M18 terminal 19 and remote keyless entry receiver connec-
tor (B) M23 terminal 4.
3. Check continuity between BCM connector (A) M18 terminal 19
and ground.
OK or NG
OK >> Replace BCM. Refer to BCS-25, "Removal and Installation of BCM" .
NG >> Repair or replace the harness.
4. CHECK REMOTE KEYLESS ENTRY RECEIVER GROUND CIRCUIT
Check continuity between remote keyless entry receiver connector M23 terminal 1 and ground.
OK or NG
OK >> GO TO 6.
NG >> GO TO 5.
5. CHECK REMOTE KEYLESS ENTRY RECEIVER GROUND CIRCUIT
Check continuity between BCM connector (A) M18 terminal 18 and remote keyless entry receiver connector
(B) M23 terminal 1.
OK or NG
OK >> Replace BCM. Refer to BCS-25, "Removal and Installa-
tion of BCM" .
NG >> Repair or replace the harness.
AB
Continuity
BCM connector TerminalRemote keyless
entry receiver
connectorTe r m i n a l
M18 19 M23 4 Yes
A
GroundContinuity
BCM connector Terminal
M18 19 No
PIIB6459E
Remote keyless entry
receiver connectorTe r m i n a l
GroundContinuity
M23 1 Yes
PIIB6460E
AB
Continuity
BCM connector TerminalRemote keyless
entry receiver
connectorTe r m i n a l
M18 18 M23 1 Yes
PIIB6461E
Page 597 of 2896
BL-108
INTELLIGENT KEY SYSTEM
Revision: June 20062007 Versa
*1: With continuously variable transmission (CVT).
*2: With manual transmission (M/T).
Steering Lock Solenoid Harness Connector Terminal LayoutEIS0 09 D5
Terminals and Reference Values for Steering Lock SolenoidEIS00922
Terminals and Reference Values for BCMEIS00923
Refer to BCS-12, "Terminals and Reference Values for BCM" .
33 RRear floor antenna (+)
signal
LOCK
Any door open → all door close
Press ignition knob switch: ON (Ignition
knob switch)
34 GRear floor antenna (-)
signal
37 BRFront outside antenna
RH (+) signal
LOCK Press door request switch RH.
38 YFront outside antenna
RH (-) signal Te r m i n a lWire
ColorItemCondition
Voltage (V)
Approx. Ignition
Switch
PositionOperation or Conditions
PIIB5502J
SIIA1910J
WIIA1283E
Te r m i -
nalWire
ColorSignal DesignationCondition
Voltage (V)
Approx. Ignition
Switch Posi-
tionOperation or Conditions
1 P Battery power supply LOCK — Battery voltage
2RSteering lock solenoid
power supplyLOCK — 5
3GRSteering lock solenoid
communication signalLOCKWhen Intelligent Key is inside
vehicle, press ignition knob
switch.
Other than the above 5
4BRSteering lock solenoid
ground—— 0
SIIA1911J