VALUES AND SETTINGS
Belt tension
07
Checking the calibration
Switch on the device (button E).
Position the calibration spring plate (Z) on the sensor as shown on the diagram (control value engraved to-
wards the top, (A) minimum value, (B) maximum value).
Tighten the presser button (1) until it goes "CLICK - CLICK - CLICK".
Check that a value X between the values (A and B) (A ≤ X ≤ B) is displayed.
NOTE: it may be necessary to perform several preliminary tests in order to obtain the correct value.
If the correct value if still not obtained after several attempts, contact SEEM.
NOTE : each device has its own calibration spring plate and they are not interchangeable.
96602R
1 Knurled button (presser)
A
B
Z Calibration plate
Calibration plate control value
SEEM
Contact your After Sales Head Office for further
information.
GENERAL INSTRUCTIONS:
_ Never refit a belt which has been removed, re-
place it.
- Never retighten a belt for which the tension
reading is between the fitting value and the
minimum operating value.
- When checking, if the tension is below the mi-
nimum operating value, change the belt.