ECU RENAULT SCENIC 2007 J84 / 2.G Electrical Equipment - Xenon Bulbs Workshop Manual

Page 3 of 38

80C -3V2 MR-372-J84-80C000$010.mif
XENON BULBS
Fault finding – Introduction80C
Program No.: V010
Vdiag No.: 05
Faults
Faults are classed as either present or stored (having appeared in a certain situation and then disappeared, or being
still present but not diagnosed in the current situation).
The present or stored status of faults should be taken into consideration when the diagnostic tool is switched on
following + after ignition feed being activated (without any system components being active).
For a present fault, apply the procedure described in the Interpretation of faults section.
For a stored fault, note the faults displayed and apply the instructions in the Notes section.
If the fault is confirmed when the notes are applied, the fault is present. Deal with the fault.
If the fault is not confirmed, check:
–The electric lines on which there is a fault;
–The connectors on those lines (corrosion, bent pins, etc.);
–The resistance of the faulty component;
–The condition of the wires (insulation melted or split, chafing, etc.).
Conformity check
The aim of the conformity check is to check statuses and parameters that do not produce a fault display on the
diagnostic tool when they are inconsistent. Therefore, this stage is used to:
–perform fault finding on faults that do not have a fault display, and which may correspond to a customer complaint.
–check that the system is operating correctly and that there is no risk of a fault recurring after repairs.
This section features the fault finding procedures for statuses and parameters, and the conditions for checking them.
If a status is not behaving normally or a parameter is outside the permitted tolerance values, consult the
corresponding fault finding page.
Customer complaints - Fault finding chart
If the diagnostic tool check is correct, but the customer complaint is still present, it should be dealt with according
to the customer complaint.
Asummary of t he overall procedure t o f ollow is provided on the following page in the form of a flow cha rt.