gearbox RENAULT SCENIC 2008 J84 / 2.G Automatic Transmission Siemens TA2000 User Guide

Page 37 of 128

AUTOMATIC TRANSMISSION
Fault finding – Interpretation of faults23A
23A-37V4 MR-372-J84-23A050$330.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
DF055
PRESENT
OR
STOREDINJECTION SYSTEM/AUTOMATIC GEARBOX CONNECTION
1.DEF : No signal
2.DEF : Signal interference
NOTESNone.
Carry out a test on the multiplex network (see 88B Multiplex).
If the fault is still present, run fault finding on the injection system (see 17B, Petrol injection or 13B, Diesel
injection).
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the
diagnostic tool.
DP0TA2000_V10_DF055/DP0TA2000_V11_DF055/DP0TA2000_V15_DF055

Page 56 of 128

AUTOMATIC TRANSMISSION
Fault finding – Interpretation of faults23A
23A-56V4 MR-372-J84-23A050$396.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
DF131
PRESENT
OR
STOREDSLIPPAGE
NOTESRun fault finding on the injection system and check that it is
operating correctly.
Deal with all other faults first.
Conditions for applying the fault finding procedure to stored faults:
Safe mode is triggered after a fault, not by the driver.
To check that there are no faults with the turbine speed sensor, apply the interpretation of fault DF038 Turbine
speed sensor circuit.
To check that there are no faults with the vehicle speed signal, apply the interpretation of fault DF048 Vehicle
speed signal.
Carry out a conformity check to detect any possible faults.
If the fault is still present, a brake or clutch in the gearbox is certainly defective.
Contact Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the
diagnostic tool.
DP0TA2000_V10_DF131/DP0TA2000_V11_DF131/DP0TA2000_V15_DF131

Page 61 of 128

AUTOMATIC TRANSMISSION
Fault finding – Conformity check23A
23A - 61V4 MR-372-J84-23A050$462.mif
SIEMENS TA2000
Vdiag No.: 10-11-15AUTOMATIC TRANSMISSION
Fault finding – Conformity check
DF177
PRESENT
OR
STOREDAUTOMATIC TRANSMISSION OVERHEATING
NOTESRun fault finding on the injection system and make sure that it is working perfectly.
If the following faults are present or stored, deal with them first:
DF003 - DF005 - DF016 - DF017 - DF018 - DF020 - DF023 - DF024 - DF036 -
DF049 - DF131
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after a road test.
To make sure that there are no faults with the gearbox oil temperature sensor, apply the interpretation of fault
DF023 Gearbox oil temperature sensor.
To make sure that there are no faults with the exchanger flow solenoid valve, apply the interpretation of fault DF017
Exchanger flow solenoid valve circuit.
Check gearbox oil grade and level.
If an operation is necessary (see MR 364 Mechanical, 23A, Automatic transmission, Filling-Levels (for
Mégane II) and MR 370 Mechanical, 23A, Automatic transmission, Draining-Filling for Scénic II)).
Check that the gearbox is not leaking oil.
Check that the water-oil exchanger is not blocked.
If the fault is still present, there is a definitely a mechanical or hydraulic fault.
Deal with the other faults then proceed with the conformity check.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2000_V10_DF177/DP0TA2000_V11_DF177/DP0TA2000_V15_DF177
MR-372-J84-23A050$462.mif

Page 63 of 128

AUTOMATIC TRANSMISSION
Fault finding – Conformity check23A
23A - 63V4 MR-372-J84-23A050$462.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
MAIN SCREEN (continued 1)
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(no present or stored faults).
Application conditions: engine stopped, ignition on.
The values indicated in this conformity check are given as examples.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
5Brake pedalET142:Brake pedal pressedYES, if the brake pedal
is depressed
NO, if the brake pedal
is not depressedIn the event of a
fault, refer to the
interpretation of this
status.
6Brake switchET003:Brake light switch
(opening)ACTIVE, if the brake
pedal is not depressed
INACTIVE, if the brake
pedal is depressedIn the event of a
fault, refer to the
interpretation of this
status.
ET004:STOP light contact
(closure)INACTIVE, if the brake
pedal is not depressed
ACTIVE, if the brake
pedal is depressed
7Selection modeET097: Manual mode INACTIVEACTIVE, if lever is in
position M
8Sequential lever
switchET127:Lower sequential
lever switchOPEN, CLOSED, if
selector lever in
position M-
In the event of a
fault, refer to the
interpretation of this
status. ET128:Upper sequential
lever switchOPEN, CLOSED, if
selector lever in
position M+
ET155:Third gear hold
contactOPEN
9Driving modeET079:Economy modeYES, if driving is
economical
NO, if driving is 'sporty' NONE
10Gearbox oil
temperaturePR004:Gearbox oil
temperature- 40 < X < 140 ˚C In the event of a
fault, consult the
interpretation of this
parameter.

Page 68 of 128

AUTOMATIC TRANSMISSION
Fault finding – Conformity check23A
23A - 68V4 MR-372-J84-23A050$462.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
SUB-FUNCTION: PRESSURE CONTROL
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(no present or stored faults).
Application conditions: engine stopped, ignition on.
The values indicated in this conformity check are given as examples.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
1Gearbox ratioET013: Gear engagedN for neutral position
1 for 1
st unlocked
2 for 2nd unlocked
R for reverse gear
positionIn the event of a
fault, refer to the
interpretation of this
status.
2Engine speedPR006:Engine speed0 rpmIn the event of a
fault, consult the
interpretation of
fault DF115.
3Oil pressurePR003: Oil pressureX < 0.2 barIn the event of a
fault, consult the
interpretation of this
parameter.
PR138:Reference pressure21 bar None.
PR146:Difference between
reference and oil
pressureX = PR138 - PR003 None.
4Oil temperaturePR004:Gearbox oil
temperature- 40 < X < 140 ˚CIn the event of a
fault, consult the
interpretation of this
parameter.

Page 71 of 128

AUTOMATIC TRANSMISSION
Fault finding – Conformity check23A
23A - 71V4 MR-372-J84-23A050$462.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
SUB-FUNCTION: LOCKUP/UNLOCKING
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(no present or stored faults).
Application conditions: engine stopped, ignition on.
The values indicated in this conformity check are given as examples.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
1Rotation speedsPR006:Engine speed 0 rpmIn the event of a
fault, consult the
interpretation of this
parameter.
PR007: Turbine speed0 rpmIn the event of a
fault, consult the
interpretation of this
parameter.
PR128:Engine/turbine speed
difference0 rpmIn the event of a
fault, consult the
interpretation of this
parameter.
2Oil pressure PR003:Oil pressure X < 0.2 barIn the event of a
fault, consult the
interpretation of this
parameter.
PR138:Reference pressure21 bar None.
PR146:Difference between
reference and oil
pressureX = PR138 - PR003 None.
3Torque
converterET071:Torque converterINACTIVEIn the event of a
fault, refer to the
interpretation of this
status.
4Oil temperaturePR004:Gearbox oil
temperature - 10 < X < 150 ˚C
- 40 < X < 140 ˚C
ET010:Oil too hot signalYES/NOYES, if the oil
temperature is
> 140 ˚C
5Driving modeET079:Economy modeYES, if driving is
economical
NO, if driving is
'sporty'None.

Page 74 of 128

AUTOMATIC TRANSMISSION
Fault finding – Conformity check23A
23A - 74V4 MR-372-J84-23A050$462.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
SUB-FUNCTION: CREEPING AT IDLE SPEED
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(no present or stored faults).
Application conditions: engine stopped, ignition on.
The values indicated in this conformity check are given as examples.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
1Oil pressurePR003:Oil pressureX < 0.2 barIn the event of a
fault, consult the
interpretation of this
parameter.
2Oil temperaturePR004:Gearbox oil
temperature-40 ˚C < X < 140 ˚C In the event of a
fault, consult the
interpretation of this
parameter.
3Engine speedPR006:Engine speed0 rpmIn the event of a
fault, consult the
interpretation of this
parameter.
4Engine speedPR007:Turbine speed0 rpmIn the event of a
fault, consult the
interpretation of this
parameter.
5Engine/turbine
speed differencePR128:Engine/turbine
speed difference0 rpmIn the event of a
fault, consult the
interpretation of this
parameter.

Page 80 of 128

AUTOMATIC TRANSMISSION
Fault finding – Interpretation of statuses23A
23A-80V4 MR-372-J84-23A050$594.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
ET010
OIL TOO HOT SIGNAL
NOTESThere must be no present or stored faults.
This status means the oil temperature is above the normal operation temperature.
The status displays NO if the gearbox oil temperature is below 140˚C.
The status changes to YES when the gearbox oil temperature rises above 140˚C.
If the correct status is not displayed, use the interpretation of fault DF177 Automatic transmission overheating.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2000_V10_ET010/DP0TA2000_V11_ET010/DP0TA2000_V15_ET010

Page 84 of 128

AUTOMATIC TRANSMISSION
Fault finding – Interpretation of statuses23A
23A-84V4 MR-372-J84-23A050$594.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
* EV: Solenoid valve.ET020
EXCHANGER FLOW CONTROL SOLENOID VALVE*
NOTESThere must be no present or stored faults.
The exchanger flow control solenoid valve is ACTIVE when the gearbox oil temperature exceeds 100˚C
and the engine speed exceeds 2000 rpm.
Otherwise the solenoid valve remains inactive.
Run command AC024 Actuator sequential control and check that the activation status changes from INACTIVE
to ACTIVE.
When powered, if the solenoid valve is ACTIVE the voltage should be 0 V.
When powered, if the solenoid valve is INACTIVE the voltage should be 12 V.
Reconnect the computer.
Activate the solenoid valves with command AC024 Actuator sequential control and check the solenoid valve
current.
If the current is 260 mA, the solenoid valve is working properly.
If the current is weaker, check the computer connections and harness up to the exchanger flow solenoid valve.
If the status of the command fails to change, use the interpretation of fault DF017 Exchanger flow solenoid valve
circuit.
If the fault is still present after the fault finding procedure for fault DF017 Exchanger flow solenoid valve circuit
has been followed, contact your Techline.
AFTER REPAIRRepeat the conformity check from the start.
Make sure that shifting up and down through each gear works properly.
DP0TA2000_V10_ET020/DP0TA2000_V11_ET020/DP0TA2000_V15_ET020

Page 100 of 128

AUTOMATIC TRANSMISSION
Fault finding – Parameter summary table23A
23A - 100V4 MR-372-J84-23A050$660.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
Tool parameter Diagnostic tool title
PR001Coolant temperature
PR003Oil pressure
PR004Gearbox oil temperature
PR006Engine speed
PR007Turbine speed
PR008Computer feed voltage
PR128Engine/turbine speed difference
PR135Standard pedal position
PR138Reference pressure
PR146Difference between reference and pressure

Page:   < prev 1-10 11-20 21-30 31-40 next >