RENAULT SCENIC 2009 J84 / 2.G Automatic Transmission AJ0 BVA Manual PDF

Page 71 of 162

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 71V3 MR-372-J84-23A000$450.mif
AJ0 BVA
Vdiag No.: 04, 05
DF273
PRESENT
OR
STOREDCLUTCH 1 SOLENOID VALVE CIRCUIT
1.DEF: Open circuit or short circuit
NOTESConditions for applying fault finding procedures to stored faults:
The fault appears after:
–in the event of short circuit+ or short circuit-:
Lever in "Drive" position, gear engaged = 1, 2, 3, 4, 5, 6 OR Gear engaged = 1 and
engine braking.
–in the event of open circuit:
Lever in "Drive" position, Gear engaged = 1, 2, 3, 4,
OR
Running command AC026 "Clutch 1 solenoid valve".
System effects:
–in the event of short circuit+:
No effect.
–in the event of open circuit or short circuit-:
If the fault occurs on gears 1 to 4, in D mode, the transmission switches to Neutral
(see DF256 Erratic gear jumps). Then system switches to fixed 5th gear mode after
the vehicle has stopped.
Customer complaint:
–in the event of short circuit+:
If the fault occurs while driving, the transmission engages fixed 5th gear.
Restarting in fixed 5th gear (no more gear changes).
Significant jolting during gear changes.
Fault warning light comes on.
–in the event of open circuit or short circuit-:
If the fault occurs while driving, the transmission engages fixed 5th gear.
Restarting in fixed 5th gear (gear change impossible)
Fault warning light comes on.
Use the Wiring Diagrams Technical Note, SCENIC II ph2.
Look for any damage to the wiring harness, and check the condition and connection of the automatic
transmission computer and hydraulic distributor connectors.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for + after ignition feed on connection 5LW of component 754.
Is the + after ignition feed still present?
If YES, move on to step 1.
If NO, move on to step 8.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AJ0_V04_DF273/AJ0_V05_DF273

Page 72 of 162

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 72V3 MR-372-J84-23A000$450.mif
AJ0 BVA
Vdiag No.: 04, 05
DF273
CONTINUED 1
Step 1:
Disconnect the connector from component 119, measure the resistance of clutch 1 solenoid valve
(on the connector of component 119) between the following connections:
●Connection code 5DL.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, contact the Techline.
If NO, move on to step 2.
Step 2:
Disconnect connector R22 and check continuity and insulation of the following connections:
●Connection code 5DL.
●Connection code 5LW.
between components 119 and R22.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Are the continuity and insulation correct?
If YES, move on to step 3.
If NO, replace the external wiring harness on the automatic transmission.
Stage 3:
Measure the resistance of clutch 1 solenoid valve (on connector R22) between the following connections:
●Connection code 5DL.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, and if the fault is still present, contact the Techline.
If NO, move on to step 4.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.

Page 73 of 162

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 73V3 MR-372-J84-23A000$450.mif
AJ0 BVA
Vdiag No.: 04, 05
DF273
CONTINUED 2
Stage 4:
Drain the automatic transmission (see, MR 370, Mechanical, 23A Automatic transmission, Oil change)
and remove the transmission housing (see, MR 370, Mechanical, 23A Automatic transmission, Hydraulic
distributor).
Disconnect the connector from component 754, measure the resistance of clutch 1 solenoid valve
(on the connector of the internal wiring harness of the transmission) between the following connections:
●Connection code 5DL.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, move on to step 5.
If NO, move on to step 6.
Stage 5:
Measure the continuity and insulation of the following connections:
●Connection code 5DL.
●Connection code 5LW.
Between components R22 and the internal connector in the transmission.
Are the continuity and insulation correct?
If YES, contact the Techline.
If NO, replace the intermediate wiring harness between connector R22 and the internal connector in the
transmission.
Stage 6:
Disconnect the connector from clutch 1 solenoid valve, measure the resistance of clutch 1 solenoid valve
between the following connections:
●Connection code 5DL.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, move on to step 7.
If NO, replace the hydraulic distributor.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.

Page 74 of 162

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 74V3 MR-372-J84-23A000$450.mif
AJ0 BVA
Vdiag No.: 04, 05
DF273
CONTINUED 3
Step 7:
Measure the continuity and insulation of the following connections:
●Connection code 5DL.
●Connection code 5LW.
Between clutch solenoid valve 1 and the internal connector on the transmission.
Are the continuity and insulation correct?
If YES, contact the Techline.
If NO, replace the internal wiring harness on the automatic transmission.
Step 8:
Check the continuity and insulation of the following connection:
●Connection code 5LW between components 119 and 754.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If + after ignition feed is not present after checking feeds and earths on the transmission computer, contact the
Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.

Page 75 of 162

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 75V3 MR-372-J84-23A000$450.mif
AJ0 BVA
Vdiag No.: 04, 05
DF274
PRESENT
OR
STOREDCLUTCH 2 SOLENOID VALVE CIRCUIT
1.DEF: Open circuit or short circuit
NOTESConditions for applying fault finding procedures to stored faults:
The fault appears after:
–in the event of short circuit+ or short circuit-:
Lever in "Drive" position, gear engaged = 1, 2, 3, 4, 5, 6 OR Gear engaged = 1 and
engine braking.
–in the event of open circuit:
Lever in "Drive" position, Gear engaged = 1, 2, 4, 6,
OR lever in "Manual" position, gear engaged = 1 and engine braking.
OR
Running command AC026 "Clutch 2 solenoid valve".
System effects:
–in the event of short circuit+:
If the fault occurs in 3rd or 5th in D mode, an erratic shift to Neutral is detected
(see DF256 Erratic gear jumps).
–in the event of open circuit or short circuit-:
–If the fault occurs in 1st in "Drive" position, shifting from 1st gear to 3rd gear.
–If the fault occurs in 1st in "Manual" mode or in 2nd, 4th or 6th in "Drive" mode, the
automatic transmission is locked.
Customer complaint:
–in the event of short circuit+:
Fault warning light comes on.
–in the event of open circuit:
–If the fault occurs in 1st in "Drive" position, shifting from 1st gear to 3rd gear.
–If the fault occurs in 1st in "Manual" mode or in 2nd, 4th or 6th in "Drive" mode, the
automatic transmission is locked.
Fault warning light comes on.
–in the event of short circuit-:
If the fault occurs while driving, the transmission engages fixed 5th gear.
Restarting in fixed 3rd gear (no more gear changes).
Fault warning light comes on.
Use the Wiring Diagrams Technical Note, SCENIC II ph2.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AJ0_V04_DF274/AJ0_V05_DF274

Page 76 of 162

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 76V3 MR-372-J84-23A000$450.mif
AJ0 BVA
Vdiag No.: 04, 05
DF274
CONTINUED 1
Look for any damage to the wiring harness, and check the condition and connection of the automatic
transmission computer and hydraulic distributor connectors.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for + after ignition feed on connection 5LW of component 754.
Is the + after ignition feed still present?
If YES, move on to step 1.
If NO, move on to step 8.
Step 1:
Disconnect the connector from component 119, measure the resistance of clutch 2 solenoid valve
(on the connector of component 119) between the following connections:
●Connection code 5DM.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, contact the Techline.
If NO, move on to step 2.
Step 2:
Disconnect connector R22 and check continuity and insulation of the following connections:
●Connection code 5DM.
●Connection code 5LW.
Between components 119 and R22.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Are the continuity and insulation correct?
If YES, move on to step 3.
If NO, replace the external wiring harness on the automatic transmission.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.

Page 77 of 162

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 77V3 MR-372-J84-23A000$450.mif
AJ0 BVA
Vdiag No.: 04, 05
DF274
CONTINUED 2
Stage 3:
Measure the resistance of clutch 2 solenoid valve (on connector R22) between the following connections:
●Connection code 5DM.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, and if the fault is still present, contact the Techline.
If NO, move on to step 4.
Stage 4:
Drain the automatic transmission (see, MR 370, Mechanical, 23A Automatic transmission, Oil change)
and remove the transmission housing (see, MR370, Mechanical, 23A Automatic transmission, Hydraulic
distributor).
Disconnect the connector from component 754, measure the resistance of clutch 2 solenoid valve
(on the connector of the internal wiring harness of the transmission) between the following connections:
●Connection code 5DM.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, move on to step 5.
If NO, move on to step 6.
Stage 5:
Measure the continuity and insulation of the following connections:
●Connection code 5DM.
●Connection code 5LW.
Between components R22 and the internal connector in the transmission.
Are the continuity and insulation correct?
If YES, contact the Techline.
If NO, replace the intermediate wiring harness between connector R22 and the internal connector in the
transmission.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.

Page 78 of 162

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 78V3 MR-372-J84-23A000$450.mif
AJ0 BVA
Vdiag No.: 04, 05
DF274
CONTINUED 3
Stage 6:
Disconnect the connector from clutch 2 solenoid valve, measure the resistance of clutch 2 solenoid valve
between the following connections:
●Connection code 5DM.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, move on to step 7.
If NO, replace the hydraulic distributor.
Step 7:
Measure the continuity and insulation of the following connections:
●Connection code 5DM,
●Connection code 5LW.
Between clutch solenoid valve 2 and the internal connector on the transmission.
Are the continuity and insulation correct?
If YES, contact the Techline.
If NO, replace the internal wiring harness on the automatic transmission.
Step 8:
Check the continuity and insulation of the following connection:
●Connection code 5LW between components 119 and 754.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If + after ignition feed is not present after checking feeds and earths on the transmission computer, contact the
Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.

Page 79 of 162

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 79V3 MR-372-J84-23A000$450.mif
AJ0 BVA
Vdiag No.: 04, 05
DF275
PRESENT
OR
STOREDCLUTCH 3 SOLENOID VALVE CIRCUIT
1.DEF: Open circuit or short circuit
NOTESConditions for applying fault finding procedures to stored faults:
The fault appears after:
–in the event of short circuit+ or short circuit-:
Lever in "Drive" position, gear engaged = 1, 2, 3, 4, 5, 6 OR Gear engaged = 1 and
engine braking.
–in the event of open circuit:
Lever in "Manual" position, gear engaged = 1 and engine braking.
OR lever in "Drive" position, gear engaged = 1, 2, 3.
OR
Running command AC030 "Clutch 3 solenoid valve".
System effects:
–in the event of short circuit+:
–If the fault occurs in 1st, 2nd or 3rd in "Drive" position, no shifting to 4th, 5th or 6th in
"Drive" position.
–If the fault occurs in 4th, 5th or 6th in "Drive" position, the transmission is in neutral
(refer to fault "neutral detection").
–in the event of open circuit or short circuit-:
–If the fault occurs in 1st in "Manual" mode or in 2nd or 3rd in "Drive" mode, the
automatic transmission is locked.
–If the fault occurs in 1st in "Drive" position, shifting from 1st gear to 4th gear.
Customer complaint:
–in the event of short circuit+:
–If the fault occurs in 1st, 2nd or 3rd in "Drive" position, no shifting to 4th, 5th or 6th in
"Drive" position.
–If the fault occurs in 4th, 5th or 6th in "Drive" position, the transmission is in neutral
(refer to fault "neutral detection").
Fault warning light comes on.
–in the event of open circuit:
–If the fault occurs in 1st in "Manual" mode or in 2nd or 3rd in "Drive" mode, the
automatic transmission is locked.
–If the fault occurs in 1st in "Drive" position, shifting from 1st gear to 4th gear.
Fault warning light comes on.
–in the event of short circuit-:
Fixed 5th gear engaged.
Restarting is in 5th gear.
Fault warning light comes on.
Use the Wiring Diagrams Technical Note, SCENIC II ph2.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AJ0_V04_DF275/AJ0_V05_DF275

Page 80 of 162

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 80V3 MR-372-J84-23A000$450.mif
AJ0 BVA
Vdiag No.: 04, 05
DF275
CONTINUED 1
Look for any damage to the wiring harness, and check the condition and connection of the transmission computer
and multifunction contact connectors.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for + after ignition feed on connection 5LW of component 754.
Is the + after ignition feed still present?
If YES, move on to step 1.
If NO, move on to step 5.
Step 1:
Disconnect the connector from component 119, measure the resistance of clutch 3 solenoid valve (on the
connector of component 119) between the following connections:
●Connection code 5Q.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, contact the Techline.
If NO, move on to step 2.
Step 2:
Disconnect connector R22 and check continuity and insulation of the following connections:
●Connection code 5Q.
●Connection code 5LW.
Between components 119 and R22.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Are the continuity and insulation correct?
If YES, move on to step 3.
If NOT, replace the external wiring harness on the automatic transmission.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another check
with the diagnostic tool.

Page:   < prev 1-10 ... 31-40 41-50 51-60 61-70 71-80 81-90 91-100 101-110 111-120 ... 170 next >