RENAULT SCENIC 2010 J95 / 3.G Petrol Injection S3000 Injection Repair Manual

Page 61 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-61
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-61V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF079
PRESENT
OR
STORED
MOTORISED THROTTLE VALVE SERVO
CO: Open circuit
1.DEF: Micro-breaks
2.DEF: Motorised throttle limit search fault
3.DEF: Faulty flap return spring
4.DEF: Safe mode
5.DEF: Motorised throttle valve flap vibrating
6.DEF: Motorised throttle control fault
7.DEF: Intake supply circuit
8.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
If faultsDF011 Sensor feed voltage no. 1,
DF078 Motorised throttle control circuit,
DF095 Throttle potentiometer circuit gang 1,
DF096 Throttle potentiometer circuit gang 2,
are present or stored, deal with these first.
Conditions for applying the fault finding procedure to stored faults:
The fault is considered present if:
– the engine speed varies,
– the engine air temperature is between 5°C and 105°C.
CO
6.DEF
NOTESSpecial note:
–level 1 fault warning light illuminated.
– defect mode type 1 and 2: vehicle and engine speed
restriction, ESP and the cruise control/speed limiter are
deactivated.
2.DEF
3.DEF
4.DEFSpecial note:
–level 1 fault warning light illuminated.
– throttle valve defect mode type 4: speed limiter at 54 mph
(90 km/h) and loss of power during acceleration.
Check the cleanliness, condition and fitting of the throttle valve.
Repair if necessary.
If the fault is still present, manually check that the throttle valve rotates correctly.
Repair if necessary.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF079/S3000_V54_DF079

Page 62 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-62
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-62V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF079
CONTINUED 1
If the fault is still present, manipulate the harness to detect a change in status (present ↔ stored).
Look for possible damage to the wiring harness, check the condition and the connection of the connectors of the
injection computer and motorised throttle valve.
Repair if necessary.
If the fault is still present, disconnect the battery and the injection computer.
Check the insulation, continuity and the absence of interference resistance of the following connections:
Injection computer, connector B, track M3 track 3 of the motorised throttle
(K4M 766/812 and 813, F4R 770 and 771)
track 4of the motorised throttle
(K4J 740, K4M 788 LPG, F4RT 774 and 776)
Injection computer, connector B, track M4 track 5 of the motorised throttle valve
(K4M 766/812 and 813, F4R 770 and 771)
track 3 of the motorised throttle
(K4J 740, K4M 788 LPG, F4RT 774 and 776)
Injection computer, connector B, track G4 track 6 of the motorised throttle valve
(K4M 766/812 and 813, F4R 770 and 771)
track 1 of the motorised throttle valve
(K4J 740, K4M 788 LPG, F4RT 774 and 776)
Injection computer, connector B, track G3 track 1 of the motorised throttle valve
(K4M 766/812 and 813, F4R 770 and 771)
track 2 of the motorised throttle valve
(K4J 740, K4M 788 LPG, F4RT 774 and 776)
Injection computer, connector B, track G2 track 2 of the motorised throttle valve
(K4M 766/812 and 813, F4R 770 and 771)
track 5 of the motorised throttle valve
(K4J 740, K4M 788 LPG, F4RT 774 and 776)
Injection computer, connector B, track D3 track 4of the motorised throttle
(K4M 766/812 and 813, F4R 770 and 771)
track 6 of the motorised throttle valve
(K4J 740, K4M 788 LPG, F4RT 774 and 776)
If the fault is still present, measure the resistance of the throttle between
– tracks3 and 5 for (K4M 766/812 and 813, F4R 770 and 771),
– tracks3 and 4 for (K4J 740, K4M 788 LPG, F4RT 774 and 776).
Replace the throttle valve if the resistance is not
–2.2Ω ±0.2Ω at 23°C for (K4M 766/812 and 813, F4R 770 and 771),
–1.6Ω ±0.2Ω at 23°C for (K4J 740, K4M 788 LPG, F4RT 774 and 776).
If the fault is still present, disconnect the battery and the injection computer.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.

Page 63 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-63
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-63V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF079
CONTINUED 2
Check the insulation, continuity and the absence of interference resistance of the following connections:
Injection computer, connector A, track G2 track 3 of the pedal potentiometer
Injection computer, connector A, track H2 track 4 of the pedal potentiometer
Injection computer, connector A, track H3 track 5 of the pedal potentiometer
Injection computer, connector A, track F2 track 2 of the pedal potentiometer
Injection computer, connector A, track F3 track 1 of the pedal potentiometer
Injection computer, connector A, track F4 track 6 of the pedal potentiometer
Repair if necessary.
If the throttle valve has been replaced, reinitialise the programming by running command RZ005:
Programming.
If the fault is still present, deal with the other faults then proceed to the conformity check.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.

Page 64 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-64
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-64V9 MR-372-J84-17B050$376.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54PETROL INJECTION
Fault finding - Interpretation of faults
DF080
PRESENT
OR
STORED
CAMSHAFT DEPHASER CIRCUIT
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: Programming of stops
2.DEF: Dephaser mechanically jammed
3.DEF: Servo-control fault
4.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
Apply the procedure for dealing with faults DF084 Actuator relay control circuit or
DF046 Battery voltage first if they are present or stored.
If faults DF154 Engine speed sensor circuit, DF119 Camshaft sensor signal and
DF080 are all present, ignore DF080 and deal with the other 2 faults first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after a road test.
See Technical Note 6506A, Injection fault finding, Camshaft dephaser.
If the fault is still present, contact the Techline.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF080/S3000_V54_DF080
MR-372-J84-17B050$376.mif

Page 65 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-65
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-65V9 MR-372-J84-17B050$376.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF081
PRESENT
OR
STOREDCANISTER BLEED SOLENOID VALVE CIRCUIT
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short-circuit to + 12 V
1.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
Apply the procedure for dealing with faults DF046 Battery voltage or DF084
Actuators relay control circuit first if they are present or stored.
CO
CC.1
1.DEF
NOTESSpecial note:
– the valve remains locked shut; there is a smell of petrol,'
–the OBD warning light is lit.
CO.1Special note:
The valve remains locked open: bucking when driving, risk
of stalling and restarting difficulty.
Check that the fuseF8 (10A) is in good condition and is working correctly.
Repair if necessary.
Check the cleanliness and condition of the fuel vapour absorber bleed solenoid valve connections.
Repair if necessary.
Measure the resistance of the fuel vapour absorber bleed solenoid valve.
Replace the fuel vapour absorber bleed solenoid valve if the resistance is not 26Ω ±4Ω at 23°C.
Check for + 12 V on track 1 of the connector of the fuel vapour absorber bleed solenoid valve, with the ignition on.
Use the "Universal bornier" to check the insulation and continuity of the following connections:
Computer, connectorB, track M2 track 1 of the fuel vapour absorber bleed
solenoid valve
Protection and Switching Unit, connectorCN,
track 6
Repair if necessary.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF081/S3000_V54_DF081

Page 66 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-66
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-66V9 MR-372-J84-17B050$376.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF081
CONTINUED
Disconnect the battery.
Disconnect the computer. Check the cleanliness and condition of the connections.
Use the "Universal bornier" to check the insulation and continuity on the following connection:
Computer, connectorC, track E1 track 2 of the petrol vapour absorber bleed
solenoid valve
Repair if necessary.
If the fault is still present, deal with the other faults then proceed with the conformity check.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.

Page 67 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-67
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-67V9 MR-372-J84-17B050$376.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF084
PRESENT
OR
STOREDACTUATOR RELAY CONTROL CIRCUIT
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short-circuit to + 12 V
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present with the engine running.
Special note:
This relay supplies the following actuators:
– the injectors
– the petrol fuel vapour absorber,
– the injection computer supply on track M2,
– the low-speed and high-speed fan assembly relays.
CO/CC.1: Actuators no longer supplied: the vehicle stalls and restart impossible.
CC.0: The actuators are supplied all the time: high electrical consumption when
stationary.
Intermittent CO: Intermittent relay cut-off: jerking while driving.
Disconnect the battery and the injection computer.
Check the cleanliness and condition of the injection actuator relay connections.
Check the cleanliness and condition of the UCH computer connections.
Repair if necessary.
Disconnect connector MN of the Protection and Switching Unit.
Check the cleanliness and condition of its connections.
Use the "Universal bornier" to check the insulation and continuity on the following connection:
Injection computer, connectorB, track D4Protection and Switching Unit, connector MN,
track 5
Repair if necessary.
If the fault is still present, carry out fault finding on the Protection and Switching Unit system (See87G, Engine
interconnection unit).
Contact the Techline.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF084/S3000_V54_DF084

Page 68 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-68
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-68V9 MR-372-J84-17B050$376.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF085
PRESENT
OR
STOREDFUEL PUMP RELAY CONTROL CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short-circuit to + 12 V
1.DEF: Non-compliance with emission control standards
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after the ignition is switched on or command AC079
Actuator static test is activated.
Special note:
–OBD warning light illuminated.
CO/CC.1: The vehicle stalls and restart impossible
CC.0: Risk of fire in the event of an accident: petrol leak.
Intermittent CO: Intermittent relay cut-off: risk of draining the battery.
If the relay does not click:
Disconnect the battery and the injection computer.
Check the cleanliness and condition of the injection actuator relay connections.
Check the cleanliness and condition of the connections of the fuel pump relay connector.
Repair if necessary.
Disconnect connector MT1 of the Protection and Switching Unit.
Check the cleanliness and condition of its connections.
Use the "Universal bornier" to check the insulation and continuity on the following connection:
Computer, connectorC, track D1Protection and Switching Unit, connector MT1,
track 5
Repair if necessary.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF085/S3000_V54_DF085

Page 69 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-69
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-69V9 MR-372-J84-17B050$376.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF085
CONTINUED
IF THE PUMP DOES NOT OPERATE
Disconnect connector CN of the Protection and Switching Unit.
Check the cleanliness and condition of its connections.
Using command AC079 Actuator static test, check for + 12 V on track 3 of the fuel pump.
If there is not + 12 V, check (using the universal bornier) the insulation and the continuity on the following
connection:
Protection and Switching Unit, connector CN,
track 1Track 3 fuel pump
Repair if necessary.
If the fault is still present, carry out fault finding on the Protection and Switching Unit system (see87G,
Engine interconnection unit).
If the fault is still present, contact the Techline.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.

Page 70 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-70
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-70V9 MR-372-J84-17B050$376.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF088
PRESENT
OR
STOREDPINKING SENSOR CIRCUIT
1.DEF: Abnormal voltage
2.DEF: Non-compliance with emission control standards
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present during a road test with a warm engine at an engine speed
above 1500 rpm.
Special note:
The wiring harness connecting the injection computer to the pinking sensor is
"shielded", from this a short circuit to + 12 V is improbable.
Check the cleanliness and condition of the pinking sensor and its connections.
Check the tightness of the pinking sensor.
Disconnect the battery and the injection computer.
Check the cleanliness and condition of the connections.
Use the "Universal bornier" to check the insulation and continuity of the following connections:
Computer, connectorB, track B3 track 2 of the pinking sensor
Computer, connectorB, track B4 track 1of the pinking sensor
Computer, connectorB, track B2Pinking sensor screening
Repair if necessary.
Check the conformity of the fuel in the tank.
Check the conformity of the spark plugs.
If the fault is still present, deal with the other faults then proceed with the conformity check.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF088/S3000_V54_DF088

Page:   < prev 1-10 ... 21-30 31-40 41-50 51-60 61-70 71-80 81-90 91-100 101-110 ... 230 next >