instrument panel RENAULT SCENIC 2011 J95 / 3.G Engine And Peripherals Siemens Injection Owner's Manual
Page 96 of 329
13B-96
MR-372-J84-13B050$468.mif
V17
13B
DIESEL INJECTION
Fault finding – Interpretation of faults
DF770
PRESENT
OR
STOREDFLOW REGULATOR CIRCUIT
CC.0 : Short circuit to earth
CC.1 : Short circuit to + 12 V
CO : Open circuit
1. DEF: Parameter at maximum limit
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault becomes present after starting the engine.
Special notes:
Level 1 fault warning light lit on the instrument panel and loss of performance, or level
2 fault warning light lit on the instrument panel with loss of performance, engine
stalling or impossible to start.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and KANGOO II Wiring
diagrams Technical Note.
Check the connection and condition of the fuel flow solenoid valve connector (orange connector), component
code 1105.
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the connection and condition of the injection computer connector, component code 120 (see MR 392,
385, 364, 370 and 417, Mechanical, 13B, Diesel injection, Diesel injection computer: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance at the terminals of the flow solenoid valve between connections 3HI1 (or 3HI for
Kangoo II) and 3FB1 (or 3FB3 for Kangoo II) (be careful of the connector of the injection main relay).
If the resistance is not between 1.5 Ω and 15 Ω, replace the pump (see Replacement of components).
With the ignition on, check for + 12 V after ignition on connection 3FB1 (or 3FB3 for Kangoo II) of the fuel flow
solenoid valve, component code 1105.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the continuity, insulation and the absence of interference resistance on the following connections:
–3FB1 (or 3FB3 for Kangoo II) between components 1105 and 983 (or 1337 for Kangoo II),
–3HI1 (or 3HI for Kangoo II) between components 110 5 and 120.
If
the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Apply test 7 Incorrect injection quantity.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF770 / SID304_V45_DF770 / SID301_V48_DF770 / SID304_V49_DF770 / SID304_V4D_DF770 / SID301_V4C_DF770
MR-372-J84-13B050$468.mif
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4CProgram No.: B1 and B2
Page 98 of 329
13B-98
MR-372-J84-13B050$468.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF773
PRESENT
OR
STOREDPRESSURE REGULATOR CIRCUIT
CC.0 : Short circuit to earth
CC.1 : Short circuit to + 12 V
CO : Open circuit
1. DEF: Parameter at maximum limit
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault becomes present after starting the engine.
Special notes:
–Level 1 fault warning light lit on the instrument panel and loss of performance, or
level 2 fault warning light lit on the instrument panel with loss of performance,
engine stalling or impossible to start.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and KANGOO II Wiring
diagrams Technical Note.
Check the connection and condition of the connector of the fuel pressure solenoid valve, component code 119 8
and the injection computer connector, component code 120 (see MR 392, 385, 364, 370 and 417, Mechanical,
13B, Diesel injection, Diesel injection computer: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance at the terminals of the pressure solenoid valve between connections 3ZQ1 and 3FB1 (or
3FB3 for Kangoo II).
(be careful of the injection main relay connector).
If the resistance is not between 1.5 Ω and 15 Ω, replace the pump (see Replacement of components).
With the ignition on, check for + 12 V after ignition on connection 3FB1 (or 3FB3 for Kangoo II) of the fuel
pressure solenoid valve, component code 1198.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the continuity, insulation and the absence of interference resistance on the following connections:
–3FB1 (or 3FB3 for Kangoo II) between components 1198 and 983 (or 1337 for Kangoo II),
–3ZQ1 (or 3ZQ for Kangoo II) between components 1198 and 120.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF773 / SID304_V45_DF773 / SID301_V48_DF773 / SID304_V49_DF773 / SID304_V4D_DF773 / SID301_V4C_DF773
Page 102 of 329
13B-102
MR-372-J84-13B050$468.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF887
PRESENT
OR
STOREDBRAKE/ACCELERATOR PEDAL POSITIONS
1. DEF: Signal inconsistency
NOTESConditions for applying the fault finding procedure to a stored fault:
Apply this fault finding procedure.
Special notes:
The brake and accelerator pedals were detected as depressed simultaneously for 30
seconds.
– Illumination of Level 2 fault warning light on the instrument panel.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and KANGOO II Wiring
diagrams Technical Note.
Check that the accelerator pedal is not jammed and that there is nothing impeding its operation (floor carpet, etc.).
Check that the brake light switch is adjusted and operating correctly.
Check the connection and condition of the accelerator pedal potentiometer connector, component code 921
(see MR 392, 385, 364, 370 and 417, Mechanical, 17B, Diesel injection, Accelerator pedal potentiometer:
Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the connection and condition of the injection computer connector, component code 120 (see MR 392,
385, 364, 370 and 417, Mechanical, 13B, Diesel injection, Diesel injection computer: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance of the pedal potentiometer, component code 921 on gang 1 between connections 3LT
and 3LR.
If the resistance is not between 0.8 kΩ and
2.6 kΩ, replace the pedal potentiometer (see MR 392, 385, 364, 370
and 417, Mechanical, 13B, Diesel injection, Accelerator pedal potentiometer:
Removal - Refitting).
Measure the resistance of the pedal potentiometer, component code 921 on gang 2 between connections 3LU
and 3LV.
If the resistance is not between 0.8 kΩ and
4.9 kΩ, replace the pedal potentiometer (see MR 392, 385, 364, 370
and 417, Mechanical, 17B, Diesel injection, Accelerator pedal potentiometer:
Removal - Refitting).
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Clear RZ001 Fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF887 / SID304_V45_DF887 / SID301_V48_DF887 / SID304_V49_DF887 / SID304_V4D_DF887 / SID301_V4C_DF887
Page 106 of 329
13B-106
MR-372-J84-13B050$468.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF991
PRESENT
OR
STOREDPARTICLE FILTER INJECTOR CONTROL CIRCUIT
CC.0 : Short circuit to earth
CC.1 : Short circuit to + 12 V
CO : Open circuit
NOTESConditions for applying the fault finding procedure to a stored fault:
– The fault is declared present after the engine is started or following a road test.
– After actuator command AC238 Particle filter injector.
If the fault is present:
CO or CC.1: Injector not actuated,
CC.0: Injector permanently actuated.
–The level 1 and OBD fault warning lights are lit on the instrument panel.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and Kangoo II Wiring
diagrams Technical Note.
Check the connection and condition of the exhaust injection solenoid valve connector, component code 1750.
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the connection and condition of the injection computer connector, component code 120 (see MR 392,
385, 364, 370 and 417, Mechanical, 13B, Diesel injection, Diesel injection computer: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance of the particle filter injector, component code 1750 between connections 3FB2 (or
3FB3 for Kangoo II) and 3AGR.
If the resistance is not:
5.2 Ω at - 40°C,
7.5 Ω at 20°C,
10.4Ω at 120°C.
Replace the injector.
With the ignition on, check for + 12 V after ignition on connection 3FB2 (or 3FB3 for Kangoo II) of the exhaust
injection solenoid valve, component code 1750.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the continuity, insulation and the absence of interference resistance on the following connections:
–3FB2 (or 3FB3 for Kangoo II) between components 1750 and 120 (or 1337 for Kangoo II),
–3AGR between components 1750 and 120.
If
the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF991 / SID304_V45_DF991 / SID301_V48_DF991 / SID304_V49_DF991 / SID304_V4D_DF991 / SID301_V4C_DF991
Page 107 of 329
13B-107
MR-372-J84-13B050$468.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF999
PRESENT
OR
STORED
PARTICLE FILTER DOWNSTREAM TEMPERATURE SENSOR
CIRCUIT
CC.0 : Short circuit to earth
CO.1 : Open circuit or short circuit to +12 V.
1. DEF: Micro-breaks
2. DEF: Signal outside lower limit
3. DEF: Signal inconsistency
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault becomes present:
– with the ignition on (for status CC.0),
– after a road test with a warm engine (for status CO. 1).
Special notes:
If the fault is present:
–The level 1 fault warning light is lit on the instrument panel.
IMPORTANT
The particle filter downstream temperature sensor only measures temperatures
above 50°C.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and Kangoo II Wiring
diagrams Technical Note.
Run command AC029 High pressure circuit sealing test and check PR381 Particle filter downstream
temperature.
If the particle filter downstream temperature is above 50°C, then the sensor is correct, otherwise continue the fault
finding procedure.
Check the connection and condition of the connector of the particle filter downstream temperature sensor,
component code 1288 (see MR 392, 385, 364, 370 and 417, Mechanical, 19B, Exhaust, Particle filter
temperature sensors: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the connection and condition of the injection computer connector, component code 120 (see MR 392,
385, 364, 370 and 417, Mechanical, 13B, Diesel injection, Diesel injection computer: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance of the particle filter downstream temperature sensor, component code 1288 between
connections 3TG and 3XU.
If the resistance is not:
106170Ω <X <106190Ω at 50°C,
33550Ω < X < 33570Ω at 100°C,
6886Ω < X < 6906Ω at 200°C,
2565Ω < X < 2585Ω at 300°C,1192Ω <X <1212Ω
at 400°C,
663Ω <X < 683Ω at 500°C,
277Ω <X < 297Ω at 700°C,
Replace the sensor (see MR 392, 385, 364, 370 and 417, Mechanical, 19B, Exhaust, Particle filter
temperature sensors: Removal - Refitting).
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF999 / SID304_V45_DF999 / SID301_V48_DF999 / SID304_V49_DF999 / SID304_V4D_DF999 / SID301_V4C_DF999
Page 113 of 329
13B-113
MR-372-J84-13B050$468.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF1002
PRESENT
OR
STOREDSTATIC REGENERATION
1. DEF: Signal outside upper limit
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault becomes present during regeneration.
Special notes:
– static particle filter regeneration fault (applied in After-Sales).
–The level 1 fault warning light is lit on the instrument panel.
Before each regeneration, check the diesel fuel level.
Before and after each regeneration, check the oil level.
Before every regeneration, check the sealing on the 5
th particle filter injector circuit using the actuator AC237
Fuel pump relay.
If the fault is still present, replace the particle filter (see MR 385, 364, 370 and 417, Mechanical, 19B, Exhaust,
Particle filter: Removal - Refitting).
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF1002 / SID304_V45_DF1002 / SID301_V48_DF1002 / SID304_V49_DF1002 / SID304_V4D_DF1002 / SID301_V4C_DF1002
Page 115 of 329
13B-115
MR-372-J84-13B050$468.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF1004
PRESENT
OR
STOREDELECTRIC FUEL PUMP RELAY CONTROL CIRCUIT
CC.0 : Short circuit to earth
CC.1 : Short circuit to + 12 V
CO : Open circuit
NOTESConditions for applying the fault finding procedure to a stored fault:
– The fault is declared present after the engine is started or following a road test.
– After running command AC237 Fuel pump relay.
Special notes:
CO/CC.1: the fuel pump is not actuated,
CC.O: the fuel pump is permanently actuated.
The level 1 fault warning light is lit on the instrument panel.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and Kangoo II Wiring
diagrams Technical Note.
Check the connection and condition of the connector of the electric fuel pump relay, component code 236.
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the connection and condition of the injection computer connector, component code 120 (see MR 392,
385, 364, 370 and 417, Mechanical, 13B, Diesel injection, Diesel injection computer: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the continuity, insulation and the absence of interference resistance on the following connections:
–3AHB between components 218 and 236,
–3AHA between components 236 and 120,
–3FB between components236 and 983,
–BP1 between components 236 and + battery supply.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF1004 / SID304_V45_DF1004 / SID301_V48_DF1004 / SID304_V49_DF1004 / SID304_V4D_DF1004 / SID301_V4C_DF1004
Page 116 of 329
13B-116
MR-372-J84-13B050$468.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF1005
PRESENT
OR
STOREDTHERMOPLUNGER CONTROL UNIT FAULT FINDING 1
CONNECTION
1. DEF: Signal inconsistency
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault becomes present after running command AC260 Thermoplunger relay.
Special notes:
If the fault is present:
The level 1 fault warning light is lit on the instrument panel.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and Kangoo II Wiring
diagrams Technical Note.
Check the connection and condition of the thermoplunger unit connector, component code 1550.
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the connection and condition of the injection computer connector, component code 120 (see MR 392,
385, 364, 370 and 417, Mechanical, 13B, Diesel injection, Diesel injection computer: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the continuity, insulation and the absence of interference resistance on the following connections:
– 3AHK between components 1550 and 120,
– 3AHL between components 1550 and 120,
– 3JAB between components 1550 and 120,
– 3JAA between components 1550 and 120,
– 3JA between components 1550 and 120.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF1005 / SID304_V45_DF1005 / SID301_V48_DF1005 / SID304_V49_DF1005 / SID304_V4D_DF1005 / SID301_V4C_DF1005
Page 120 of 329
13B-120
MR-372-J84-13B050$468.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF1008
PRESENT
OR
STOREDTURBINE UPSTREAM TEMPERATURE REGULATION
1. DEF: Parameter at maximum limit
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault becomes present after a road test with particle filter regeneration.
Special notes:
If the fault is present:
The level 1 fault warning light is lit on the instrument panel.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and Kangoo II Wiring
diagrams Technical Note.
Check the condition of the air circuit upstream of the turbine.
Check that circuit is not leaking and does not have cracks.
Check the connection and condition of the connector of the turbine upstream temperature sensor, component
code 1589.
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the connection and condition of the injection computer connector, component code 120 (see MR 392,
385, 364, 370 and 417, Mechanical, 13B, Diesel injection, Diesel injection computer: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance of the turbine upstream temperature sensor, component code 1589 between
connections 3B
and 3JQ.
If the resistance is not:
5910Ω < X < 5930Ω at 300°C,
1760Ω < X < 1780Ω at 400°C,
714Ω < X < 734Ω at 500°C,353Ω < X < 373Ω at 600°C,
177Ω < X < 227Ω at 700°C,
106Ω < X < 156Ω at 800°C,
replace the turbine upstream temperature sensor.
With the ignition on, check the continuity, insulation and absence of interference resistance on the following
connections:
–3JQ between components 1589 and 120,
–3B between components 1589 and 120.
If the connection(s) are faulty and there is a repair method (see
Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, replace the turbine upstream temperature sensor.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF1008 / SID304_V45_DF1008 / SID301_V48_DF1008 / SID304_V49_DF1008 / SID304_V4D_DF1008 / SID301_V4C_DF1008
Page 121 of 329
13B-121
MR-372-J84-13B050$468.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF1009
PRESENT
OR
STOREDCATALYTIC CONVERTER 1 DOWNSTREAM TEMPERATURE
REGULATION
1. DEF: Signal outside lower limit
2. DEF: Signal outside upper limit
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault becomes present after a road test with particle filter regeneration.
Special notes:
If the fault is present:
The level 1 fault warning light is lit on the instrument panel.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and Kangoo II Wiring
diagrams Technical Note.
Check the connection and condition of the connector of the catalytic converter 1 downstream temperature
sensor, component code 1765.
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the connection and condition of the injection computer connector, component code 120 (see MR 392,
385, 364, 370 and 417, Mechanical, 13B, Diesel injection, Diesel injection computer: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
With the ignition on, check the continuity, insulation and absence of interference resistance on the following
connections:
–3AGX between components 1765 and 120,
–3AGY between components 1765 and 120.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, replace the turbine upstream temperature sensor.
While the engine is idling, check the return flow rate at the injectors.
After 5minutes the return volume must be between 16 mland 24 ml per injector.
If this tolerance is incorrect, replace the faulty injector(s).
Check the temperature of the catalytic converter; check that it is not too low.
Check that the exhaust system is not pierced.
Replace any faulty components.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF1009 / SID304_V45_DF1009 / SID301_V48_DF1009 / SID304_V49_DF1009 / SID304_V4D_DF1009 / SID301_V4C_DF1009