Tool faultAssociated
DTCDiagnostic tool title
DF001115 Coolant temperature sensor circuit
DF002110 Air temperature sensor circuit
DF004235 Turbocharging pressure sensor circuit
DF007190 Rail pressure sensor circuit
DF011641 Sensor supply voltage no. 1
DF012651 Sensor supply voltage no. 2
DF013697 Sensor supply voltage no. 3
DF017670 Preheating unit control circuit
DF018480 Low speed fan assembly control circuit (except Vdiag 58, 5C)
DF019481 High speed fan assembly control circuit (except Vdiag 58, 5C)
DF025380 Pre-postheating unit diagnostic line
DF026201 Cylinder 1 injector control circuit
DF027202 Cylinder 2 injector control circuit
DF028203 Cylinder 3 injector control circuit
DF029204 Cylinder 4 injector control circuit
DF0321641 Thermoplunger 1 relay control circuit
DF0331642 Thermoplunger 2 relay control circuit
DF0341643 Thermoplunger 3 relay control circuit
DF038606 Computer
DF046560 Battery voltage
DF0472505 Computer feed voltage
DF051575 Cruise control/speed limiterfunction
DF052200 Injector control circuit
DF05445 Turbocharging solenoid valve control circuit
DF056100 Air flow sensor circuit
DF059301 Misfiring on cylinder 1
DF060302 Misfiring on cylinder 2
DF061303 Misfiring on cylinder 3
DF062304 Misfiring on cylinder 4
DF065300 Combustion misfire
DIESEL INJECTION
Fault finding – Fault summary table

Page 31 of 510

13B-31
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$071.mif
13B
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
DF001
PRESENT
OR
STOREDCOOLANT TEMPERATURE SENSOR CIRCUIT
CC.0: Short circuit to earth
CO.1: Open circuit or short circuit to +12 V
NOTESPriorities when dealing with a number of faults:
– DF046 Battery voltage.
Conditions for applying the fault finding procedure to a stored fault:
If the fault is declared present after:
– the ignition is switched on,
– starting the engine,
– a road test.
Special notes:
If the fault is present:
– the thermoplungers are no longer controlled,
– the coolant temperature: PR064 Coolant temperature is fixed at 119°C (with the
engine running),
– the preheating phase lasts longer than 4 seconds,
– the low-speed fan assembly is continuously supplied,
– the high speed fan assembly is continuously supplied (for Vdiag 20, 24, 58, 5C, 26,
28, 60, 62),
– smoke may be emitted from the exhaust,
– noise may be heard when hot starting.
The level 1 warning light is illuminated.
The EOBD (European On Board Diagnostic) warning light is lit (for Vdiag 20, 24, 58,
5C, 26, 28, 60, 62)
Use bornier Elé.1681 for any operations on the computer connectors.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
EDC16CP33_V18_DF001 / EDC16CP33_V1C_DF001 / EDC16CP33_V54_DF001 / EDC16CP33_V20_DF001 / EDC16CP33_V58_DF001 /
EDC16CP33_V5C_DF001 / EDC16CP33_V24_DF001 / EDC16CP33_V04_DF001 / EDC16CP33_V08_DF001 / EDC16CP33_V44_DF001 /
EDC16CP33_V4C_DF001 / EDC16CP33_V34_DF001 / EDC16CP33_V38_DF001 / EDC16CP33_V74_DF001 / EDC16CP33_V28_DF001 /
EDC16CP33_V62_DF001/ EDC16CP33_V26_DF001 / EDC16CP33_V60_DF001
DIESEL INJECTION
Fault finding – Interpretation of faults

Page 34 of 510

13B-34
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$071.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
DF002
PRESENT
OR
STOREDAIR TEMPERATURE SENSOR CIRCUIT
CC.0: Short circuit to earth
CO.1: Open circuit or short circuit to +12 V
NOTESPriorities when dealing with a number of faults:
– DF046 Battery voltage.
Conditions for applying the fault finding procedure to a stored fault:
If the fault is declared present after:
– the ignition is switched on,
– starting the engine,
– a road test.
Special notes:
If the fault is present:
–The EOBD (European On Board Diagnostic) warning light is lit.
– the thermoplungers are inhibited,
– the inlet air temperature is in defect mode, PR059 Inlet air temperature = 20°C (with
the engine running).
The air temperature sensor is integrated into the air flowmeter.
Use bornier Elé. 1681 for all operations on the engine management computer
connectors.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
EDC16CP33_V18_DF002 / EDC16CP33_V1C_DF002 / EDC16CP33_V54_DF002 / EDC16CP33_V20_DF002 / EDC16CP33_V58_DF002 /
EDC16CP33_V5C_DF002 / EDC16CP33_V24_DF002 / EDC16CP33_V04_DF002 / EDC16CP33_V08_DF002 / EDC16CP33_V44_DF002 /
EDC16CP33_V4C_DF002 / EDC16CP33_V34_DF002 / EDC16CP33_V38_DF002 / EDC16CP33_V74_DF002 / EDC16CP33_V28_DF002 /
EDC16CP33_V62_DF002/ EDC16CP33_V26_DF002 / EDC16CP33_V60_DF002

Page 37 of 510

13B-37
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$071.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
DF004
PRESENT
OR
STOREDTURBOCHARGING PRESSURE SENSOR CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF:Consistency between turbocharging pressure and atmospheric pressure.
NOTESPriorities when dealing with a number of faults:
– DF011 Sensor supply voltage no. 1.
– DF046 Battery voltage.
Conditions for applying the fault finding procedure to a stored fault:
If the fault is declared present after:
– the ignition is switched on,
– starting the engine,
– a road test.
Special notes:
Use bornier Elé.1681 for any operations on the injection computer connectors.
If the fault is present:
– engine torque limited,
– turbocharging pressure is in defect mode, PR041 Turbocharging pressure = 0.75
bar,
–the level 1 and EOBD (European On Board Diagnostic) warning lights are lit.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
EDC16CP33_V18_DF004 / EDC16CP33_V1C_DF004 / EDC16CP33_V54_DF004 / EDC16CP33_V20_DF004 / EDC16CP33_V58_DF004 /
EDC16CP33_V5C_DF004 / EDC16CP33_V24_DF004 / EDC16CP33_V04_DF004 / EDC16CP33_V08_DF004 / EDC16CP33_V44_DF004 /
EDC16CP33_V4C_DF004 / EDC16CP33_V34_DF004 / EDC16CP33_V38_DF004 / EDC16CP33_V74_DF004 / EDC16CP33_V28_DF004 /
EDC16CP33_V62_DF004/ EDC16CP33_V26_DF004 / EDC16CP33_V60_DF004

Page 103 of 510

13B-103
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$072.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
DF038
CONTINUED
2.DEFNOTESNone.
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the fault is still present contact Techline.
3.DEF
NOTES
Priorities when dealing with a number of faults: Deal with
faults
DF047 Computer supply voltage or DF046 Battery
voltage
first if they are present or stored.
If either of faults DF047 Computer supply voltage or DF046 Battery voltage is present or stored, clear the fault
after dealing with DF046 or DF047.
If the fault is still present, contact the Techline.

Page 104 of 510

13B-104
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$072.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
DF046
PRESENT
OR
STOREDBATTERY VOLTAGE
1.DEF: Above maximum threshold
2.DEF: Below minimum threshold
3.DEF: Initialisation not done.
NOTESConditions for applying the fault finding procedure to a stored fault:
If the fault is declared present after:
– starting the engine,
– a road test.
Special notes:
Computer operating voltage: 6 V < operating voltage < 16.5 V.
It is then not possible to start the engine.
Use bornier Elé. 1681 for any operations on the injection computer connectors.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
1.DEF
NOTESNone.
Check the charging circuit; apply Technical Note 6014A Checking the charging circuit.
Carry out the necessary repairs.
EDC16CP33_V18_DF046 / EDC16CP33_V1C_DF046 / EDC16CP33_V54_DF046 / EDC16CP33_V20_DF046 / EDC16CP33_V58_DF046 /
EDC16CP33_V5C_DF046 / EDC16CP33_V24_DF046 / EDC16CP33_V04_DF046 / EDC16CP33_V08_DF046 / EDC16CP33_V44_DF046 /
EDC16CP33_V4C_DF046 / EDC16CP33_V34_DF046 / EDC16CP33_V38_DF046 / EDC16CP33_V74_DF046 / EDC16CP33_V28_DF046 /
EDC16CP33_V62_DF046/ EDC16CP33_V26_DF046 / EDC16CP33_V60_DF046

Page 105 of 510

13B-105
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$072.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
DF046
CONTINUED
2.DEFNOTESNone.
Using a voltmeter, take a reading of the battery voltage at its terminals.
Compare this value with the value displayed by the diagnostic tool PR074 Battery voltage.
If there is no difference (less than 1 V):
– Recharge and test the battery. If it is faulty, replace it.
– Check the charging circuit: Technical Note 6014A Checking the charging circuit.
If there is a difference (greater than 1 V):
– Check the tightness and the condition of the battery terminals.
Using the appropriate wiring diagram:
–Check the continuity and absence of interference resistance on the following connection:
•3FB between components 120 and 983 or 1337.
Check the conformity of the earths on connections NT of component 120.
If the connection or connections are faulty and if there is a repair method (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
3.DEF
NOTESOnly deal with this fault when it is present.
Switch off the ignition, wait for the diagnostic tool message (maximum wait 8 min): Loss of dialogue with the
computer: EDC16 CP33, check the tool connection and the computer supply voltage then switch on the
ignition again and check whether the fault is still present.
If the fault is still present, contact the Techline.

Page 111 of 510

13B-111
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$072.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
DF054
PRESENT
OR
STOREDTURBOCHARGING SOLENOID VALVE CONTROL CIRCUITCO: open circuit
CC.1: short-circuit to + 12 V
CC.0: Short circuit to earth
1.DEF: Internal electronic fault
NOTESPriorities when dealing with a number of faults:
– DF046 Battery voltage.
Conditions for applying the fault finding procedure to a stored fault:
If the fault is declared present after:
– the ignition is switched on.
– starting the engine,
– a road test,
– actuator command AC004 Turbocharging solenoid valve.
Special notes:
If the fault is present:
– turbocharging is no longer authorised,
– the EGR function is inhibited,
–the level 1 and EOBD (European On Board Diagnostic) warning lights are lit.
Use bornier Elé.1681 for any work on the injection computer connectors.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
CO
NOTESNone.
Check the condition of the turbocharging solenoid valve connector (see Wiring Diagram Technical Note, Laguna
II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 1475).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
EDC16CP33_V18_DF054 / EDC16CP33_V1C_DF054 / EDC16CP33_V54_DF054 / EDC16CP33_V20_DF054 / EDC16CP33_V58_DF054 /
EDC16CP33_V5C_DF054 / EDC16CP33_V24_DF054 / EDC16CP33_V04_DF054 / EDC16CP33_V08_DF054 / EDC16CP33_V44_DF054 /
EDC16CP33_V4C_DF054 / EDC16CP33_V34_DF054 / EDC16CP33_V38_DF054 / EDC16CP33_V74_DF054 / EDC16CP33_V28_DF054 /
EDC16CP33_V62_DF054 / EDC16CP33_V26_DF054 / EDC16CP33_V60_DF054

Page 160 of 510

13B-160
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$073.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF209
PRESENT
OR
STOREDEGR VALVE POSITION SENSOR CIRCUITCC.0: Short circuit to earth
CO.0: Open circuit or short circuit to earth
CO.1: Open circuit or short circuit to +12 V
1.DEF: Open circuit or short circuit
NOTESPriorities when dealing with a number of faults:
– DF046 Battery voltage.
– DF012 Sensor supply voltage no. 2.
Conditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the ignition is switched on.
– the engine is started,
– a road test.
Special notes:
If the fault is present:
–the EOBD (European On Board Diagnostic) warning light is lit,
– EGR programming cut-off: valve in the closed position,
– particle filter regeneration is inhibited.
Use bornier Elé. 1681 for all operations on the engine management computer
connector.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
CO.1
1.DEF
NOTESNone.
Check the condition of the EGR valve (see Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2,
Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 1460 or 169).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
EDC16CP33_V18_DF209 / EDC16CP33_V1C_DF209 / EDC16CP33_V54_DF209 / EDC16CP33_V20_DF209 / EDC16CP33_V58_DF209 /
EDC16CP33_V5C_DF209 / EDC16CP33_V24_DF209 / EDC16CP33_V04_DF209 / EDC16CP33_V08_DF209 / EDC16CP33_V44_DF209 /
EDC16CP33_V4C_DF209 / EDC16CP33_V34_DF209 / EDC16CP33_V38_DF209 / EDC16CP33_V74_DF209 / EDC16CP33_V28_DF209 /
EDC16CP33_V62_DF209 / EDC16CP33_V26_DF209 / EDC16CP33_V60_DF209
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74

Page 170 of 510

13B-170
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$073.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF249
PRESENT
OR
STOREDINJECTOR CONTROL
1.DEF: Internal electronic fault
NOTESConditions for applying the fault finding procedure to a stored fault:
If the fault becomes present after:
– the ignition is switched on,
– the engine is started.
Priorities when dealing with a number of faults:
– DF046 Battery voltage,
– DF026 Cylinder 1 injector control circuit,
– DF027 Cylinder 2 injector control circuit,
– DF028 Cylinder 3 injector control circuit,
– DF029 Cylinder 4 injector control circuit.
Special notes:
If the fault is present:
– in certain cases, the level 2 warning light is lit and the engine is stopped.
Use bornier Elé.1681 for all operations on the engine management computer.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
This fault appears when the computer detects a fault on the injector control section.
Check the condition of the injector connectors (see Wiring Diagram Technical Note, Laguna II ph2, Vel Satis
ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component codes 193, 194, 195, 196).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
EDC16CP33_V18_DF249 / EDC16CP33_V1C_DF249 / EDC16CP33_V54_DF249 / EDC16CP33_V20_DF249 / EDC16CP33_V58_DF249 /
EDC16CP33_V5C_DF249 / EDC16CP33_V24_DF249 / EDC16CP33_V04_DF249 / EDC16CP33_V08_DF249 / EDC16CP33_V44_DF249 /
EDC16CP33_V4C_DF249 / EDC16CP33_V34_DF249 / EDC16CP33_V38_DF249 / EDC16CP33_V74_DF249 / EDC16CP33_V28_DF249 /
EDC16CP33_V62_DF249 / EDC16CP33_V26_DF249 / EDC16CP33_V60_DF249
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74

Page:   1-10 11-20 next >