length RENAULT TWINGO 2009 2.G Electrical Equipment - Parking Distance Control Workshop Manual

Page 27 of 43

PARKING DISTANCE CONTROL
Fault finding - Conformity check
87F
87F - 27V2 MR-413-X44-87F000$528_eng.mif
Vdiag No.: 04 08
MAIN SCREEN (CONTINUED)
NOTESOnly perform this conformity check after a thorough check with the diagnostic tool.
Conditions for applying the fault finding procedure: ignition on.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
5Buzzer controlET002:Buzzer controlACTIVE when the buzzer
sounds.
INACTIVE if not.In the event of a fault,
consult the interpretation
of status ET002.
6Proximity
sensorsPR001:Left-hand
outer sensor
distance26 cm < X < 150 cm
depending on the distance
from the obstacle (“out of
range” value: 0 cm).In the event of a fault, refer
to the interpretation of the
parameter PR001.
PR002:Left-hand
inner sensor
distance26 cm < X < 150 cm
depending on the distance
from the obstacle (“out of
range” value: 0 cm).If there is a fault, refer to
the interpretation of
parameter PR002.
PR003:Right-hand
outer sensor
distance26 cm < X < 150 cm
depending on the distance
from the obstacle (“out of
range” value: 0 cm).In the event of a fault,
consult the interpretation
of parameter PR003.
PR004:Right-hand
inner sensor
distance26 cm < X < 150 cm
depending on the distance
from the obstacle (“out of
range” value: 0 cm).If there is a fault, refer to
the interpretation of
parameter PR004.
PR005:Shortest
distance
calculated26 cm < X < 150 cm
depending on the distance
from the obstacle (value
out of range or less than
30 cm: 0 cm).If there is a fault, refer to
the interpretation of
parameter PR005.
7Caravan towbarPR026:Distance from
the caravan
attachment26 cm < X < 35 cm
This distance allows the
threshold point (0 cm)
from the rear of the vehicle
to be redetermined
according to the length of
the caravan towbarIn the event of a
permanent or erratic
warning signal, check that
no components are
disrupting the
measurement (sticker,
mud, snow on the rear
bumper, etc.) then
increase the distance of
the caravan towbar cm by
cm, using configuration
VP003 “Caravan towbar
distance”.

Page 43 of 43

PARKING DISTANCE CONTROL
Fault finding - Fault Finding Chart
87F
87F - 43V2 MR-413-X44-87F000$924_eng.mif
Vdiag No.: 04 08
ALP4 buzzer sounds continuously (with caravan attachment)
NOTESOnly investigate this customer complaint after a full check using the diagnostic tool
(there must be no present or stored faults).
Make sure it is a Renault caravan attachment.
Check that the cover is correctly aligned with the caravan towing
hitch.
If it is incorrectly aligned, realign it or remove it.
Is the fault still present?
YES
Using the diagnostic tool, gradually increase the distance between the central sensors and the ball on the caravan
attachment centimetre by centimetre (this distance enables the threshold point to be redetermined (0 cm) from the
rear of the vehicle depending on the length of the caravan attachment) using configuration VP003 “Caravan
attachment distance” (maximum distance: 35 cm). The caravan attachment distance can be checked with
parameter PR026.
End of fault finding procedure.
NOEnd of fault finding
procedure.
AFTER REPAIRCheck that the system is operating correctly.