SSANGYONG NEW ACTYON SPORTS 2013 Service Manual

Page 681 of 751

14-20
Even friction coefficient road Uneven friction coefficient road
Driving Force
Braking Force
Supporting the Vehicle Weight ▶Transferring the Driving Force & Braking Force to Road ▶
5. FUNCTIONS OF TIRE
Supporting the Vehicle Weight ▶

Page 682 of 751

01-36810-01
1. SPECIFICATIONS
Description Specification
HeaterCore size (mm²)200 x 165.5 x 25
Capacity (kcal/h) 4,700
EvaporatorCore size (mm²)254.8 x 196.7 x 60
Capacity (kcal/h) 4,700
Blower Supplied power (W) 240 + 10% Max (at12V)
Fan speed (rpm)2900 ± 200
Supply voltage (V) 12.0
PTC Supply power (W) 900~1,050
Compressor Capacity (cc/rev) 170
Diameter of pulley (mm) 120
Max. speed (rpm) 8,000
Supply voltage (V) 12.0
Power consumption (A) 2.2
Discharge pressure (kgf/cm²G)8~10
Power transistor Supply voltage (V) 12.0
Operating temperature (℃) -30℃~60℃
ResistanceHi-Low (Ω) 2.0 Ω ± 10%
Hi-ML (Ω) 0.9 Ω ± 10%
Hi-MH (Ω) 0.4 Ω ± 10%

Page 683 of 751

01-4
2. MAJOR CHANGES
Console rear duct
Console rear duct bracket removed and upper part's appearance changed due to changed cup
holder/poam pad used
Poam pad
Bracket

Page 684 of 751

01-56810-01
3. COMPONENTS
Blower and evaporator assembly
Actuator assembly - Intake
Air filter assembly
Cover - Air filter
Blower motor assembly
Resistor
Expansion valve assembly
Wiring assembly - Heater & evaporator
Heater assembly 1.
2.
3.
4.
5.
6.
7.
9.
10.Actuator assembly - Temperature
Actuator assembly - Mode
Heater assembly - PTC
Control assembly - Heater and A/C control
Bulb
Insert assembly - Ventilation
Sensor assembly - Humid and Incar
Sensor assembly - Intake 11.
12.
15.
20.
21.
22.
23.
24.

Page 685 of 751

01-6
Compressor Assy-A/CON
Condenser Assy
Receiver Drier & Brkt Assy
Hose Assy-Discharge & Suction
Pipe Assy-Joint
Pipe Assy-Liquid No1
Pipe Assy-Liguid No2
Hose Assy-Liguid
Hose Assy-Heater Inlet
Hose Assy-Heater Outlet
Hose-Drain 1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.

Page 686 of 751

01-76810-01
Duct assembly - Console front
Screw
Duct assembly - Console rear
Duct assembly - Console foot
Duct assembly - Foot 1.
4.
8.
9.
10.

Page 687 of 751

01-8
The FATC has a self-diagnosis function that can diagnose the system by itself. Before checking a
component, be sure to check the fault code by using the self-diagnosis function. The self-diagnosis
consists of 6 steps. The temperature control dial (step 2 to 5) and fan speed dial (step 6) are used to
enter each step of the self-diagnosis. The 6 steps of the self-diagnosis are:
▶ Step 1
▶ Step 2
▶ Step 3
▶ Step 4- The VFD and all LED segments are checked for proper illumination.
- The sensors and air mix door are checked for proper operation.
- The position and condition of the air source door and mode door are checked.
The actuator door position, fan speed and compressor operation are checked. Pressing the
defroster switch after entering step 4 changes the diagnosis mode as follows: 41 -> 42 -> 43 ->
44 -> 45 -> 46 -> 41. -
4. TROUBLESHOOTING
1) Overview

Page 688 of 751

01-96810-01
▶ Step 5
Ambient
temperature
display
51
Interior
temperature
displayIntake air
temperature display
Ambient
temperature
sensorInterior
temperature
sensorIntake air temperature
sensor
▶ Step 6
To enter the step 6 from 5, turn the fan speed dial lightly toward the right not using the
temperature control dial. In this step, you can decrease or increase by up to 3 degrees from the
temperature set on the A/C controller. -You can check that the temperature value from each temperature sensor is displayed properly in
this step. Pressing the defroster switch changes the temperature value that appears on the
display in the order as follows: -
2) Self-diagnosis step
(1) Step 1
Turn the ignition ON and press the OFF switch for 5 sec. or more within 10 sec.
Then the first step of the self-diagnosis is started as shown in the below figure.
2. Display for checking VFD and all LED segments
1. Press OFF switch for 5 sec. or more

Page 689 of 751

01-10
(2) Step 2
The sensors and air mix door are checked for proper operation in this step. When the step 2 is started,
the number "2", which indicates that the system is in the step 2, apprears on the display and the check
for sensors is performed. Once the check is done (for 10 to 20 sec.), the one digit number between 0
and 8 is added behind "2". "20" means there is no fault code. For the meaning of the rest of the
numbers, refer to the description below.
1. Turn temperature dial lightly toward right to enter step 2
10 to 20
sec.
System starts sensor
check after "2" is displayed 2.
Fault code for sensor
appears and blinks 3.
Fault code no. 1
(ambient temperature
sensor) blinks twiceFault code no. 5 (sun
sensor) blinks twice
(fault codes appears
sequentially)
If "-" is displayed before "2", it means that
the sensor for that flashing fault code has
a short circuit.
Ambient temperature
sensor short circuited
Refer to the following table for the meaning of the fault code.

Page 690 of 751

01-116810-01
(3) Step 3
In this step, you can check the position and condition of the air source door and mode door. To start step
3, turn the temperature control dial lightly toward the right and confirm that the number 3 appears on the
display. It takes several tens of seconds to finish the check. If there is no fault code, "30" is displayed.
And if there is a malfunction, the corresponding fault code is added as described in the step 2.
Turn temperature dial lightly toward
right to enter step 3 1.
System starts sensor
check after "3" is
displayed 2. Fault code for
sensor appears and
blinks (30 is
displayed when
there is no fault) 3.
Refer to the following table for the meaning of the fault code.