SUBARU LEGACY 1997 Service Repair Manual

Page 1451 of 3342

B4M0061A
2. CONTROL UNIT
Check circuit continuity between each terminal, when push
control switch is turned ON.
Terminal
No.Mode selector switch RECIRC switch
A/C
switchIllumi.
VENT BI-LEV HEATDEF/
HEATDEF RECIRC FRESH
1
2
3
4
5
6
7
8
9
10
11
12

13
14
15
16
17
18
19
B4M0062A
C: ADJUSTMENT
1) Operate temperature control lever to“FULL COLD”
position.
2) Install control cable to lever
1. While pushing outer
cable, secure control cable with clip
2.
D: INSTALLATION
Installation is in the reverse order of removal.
NOTE:
Before control unit installation, set temperature control
lever to“FULL COLD”position.
10
4-6SERVICE PROCEDURE
4. Control Unit

Page 1452 of 3342

B5M0025
5. Intake Door Motor
A: REMOVAL
1) Disconnect GND cable from battery.
2) Remove glove box and pocket back panel. <Ref. to 5-4
[W1A0].>
3) Remove heater duct or evaporator. (With A/C model).
<Ref. to 4-7 [W14A0].>
G4M0561
4) Remove intake unit from the vehicle.
B4M1428A
5) Remove screws which secure intake door motor to
intake unit.
NOTE:
Ensure that RECIRC switch is set to“ON”.
B4M1429A
11
4-6SERVICE PROCEDURE
5. Intake Door Motor

Page 1453 of 3342

B4M0294A
B: INSPECTION
1) When approx. 12 V is applied to the intake door motor
terminals, intake door motor operates as follows:
Intake
door motor
positionTerminal
Intake door motor operation

FRESH
3*
2**2*
1**Door motor moved to FRESH position.
RECIRC1*
3**Door motor moved to RECIRC position.
*: LHD model
**: RHD model
B4M1430A
B4M1431A
2) Connect harness to intake door motor.
3) Turn ignition switch to“ACC”and RECIRC switch to
“ON”then, set to“RECIRC”.
NOTE:
Ensure that intake door motor is set in the“RECIRC”mode.
4) Install intake door motor on intake unit.
5) Secure rod holder to link, and install link to intake unit.
6) Manually set rod in the“RECIRC”mode, and secure to
rod holder.
7) Operate mode selector switch to ensure that system
changes from intake air to“RECIRC”and from“RECIRC”
to intake air in full-stroke range.
C: INSTALLATION
Installation is in the reverse order of removal.
12
4-6SERVICE PROCEDURE
5. Intake Door Motor

Page 1454 of 3342

B4M0063
6. Mode Door Motor
A: REMOVAL
1) Remove instrument panel. <Ref. to 5-4 [W1A0].>
2) Remove mode door motor.
B4M0064A
B: INSPECTION
1) When approx. 12 V is applied to the mode door motor
terminals, mode door motor operates as follows:
Terminal No.
Mode door motor
21
Polarity of power supply
terminalsMode door motor
operationDirection of linkage
rotation
+ VENT,DEF Clockwise
+ DEF,VENT Counterclockwise
2) Check mode door motor position switch.
When the mode door motor is moved to each mode posi-
tion by using the mode selector switch, check if continuity
exists between each terminal as follows:
Mode selector switch
positionsTerminal No.
VENT 8 or 7
9 (GND) BI-LEV 6 or 7
HEAT 5or6
DEF/HEAT 4 or 5
DEF 3or4
C: INSTALLATION
Installation is in the reverse order of removal.
13
4-6SERVICE PROCEDURE
6. Mode Door Motor

Page 1455 of 3342

1. Air Conditioning System
A: SPECIFICATIONS
Item Specifications
Type of air conditionerReheat air-mix type
Cooling capacity (IMACA)4.885 kW
(4,200 kcal/h, 16,666 BTU/h)
RefrigerantHFC-134a (CH
2FCF3)
[0.55 — 0.65 kg
(1.21 — 1.43 lb)]
CompressorType 5-vane rotary, fix volume (DKV-14D)
Discharge 140 cm
3(8.54 cu in)/rev
Max. permissible speed 7,000 rpm
Magnet clutchTy p eDry, single-disc type
Power consumption 45 W
Type of belt V-Ribbed 4 PK
Pulley dia. (effective dia.) 125 mm (4.92 in)
Pulley ratio1.064
CondenserType Corrugated fin (Multi-flow)
Core face area 0.215 m
2(2.31 sq ft)
Core thickness 19 mm (0.75 in)
Radiation area 4.7 m
2(51 sq ft)
Receiver drier Effective inner capacity 290 cm3(17.70 cu in)
Expansion valve TypeInternal equalizing
EvaporatorTy p eA-laminate
Dimensions (W x H x T)74 x 224 x 235 mm
(2.91 x 8.82 x 9.25 in)
Blower fanFan typeSirocco fan
Outer diameter x width 150 x 75 mm (5.91 x 2.95 in)
Power consumption 230 W at 12 V
Condenser fan
(Sub fan)Motor typeMagnet
Power consumption 120 W at 12 V
Fan outer diameter 320 mm (12.60 in)
Radiator fan
(Main fan)Motor typeMagnet
Power consumption 120 W at 12 V
Fan outer diameter 320 mm (12.60 in)
Idling speed with
F.I.C.D. in operationMPFI model 850±100 rpm (700±100 rpm “D” range in AT model)
Dual switch
(Pressure switch)
High-pressure line
B4M0755A
Compressor relief valve
blow-out pressure
B4M0084A
Thermo control
amplifier working
temperature
(Evaporator outlet air)
B4M0756A
2
4-7SPECIFICATIONS
1. Air Conditioning System

Page 1456 of 3342

1. Air Conditioning System
1. LHD MODEL
B4M0757A
1Receiver drier bracket

2Pipe (Receiver drier—Evaporator module)

3Receiver drier

4Evaporator unit

5Hose (Low-pressure)

6A/C relay

7Fuse

8Hose (High-pressure)

9Compressor

10Condenser

11Pipe (Condenser—Receiver drier)
Tightening torque: N⋅m (kg-m, ft-lb)
T1: 7.4±2.0 (0.75±0.2, 5.4±1.4)
T3: 15±5 (1.5±0.5, 10.8±3.6)
T3: 15±3 (1.5±0.3, 10.8±2.2)
T4: 25±5 (2.5±0.5, 18.1±3.6)
3
4-7COMPONENT PARTS
1. Air Conditioning System

Page 1457 of 3342

2. RHD MODEL
B4M0683A
1Receiver drier

2Pipe (Receiver drier—Evaporator module)

3Evaporator unit

4Hose (Low-pressure)

5A/C relay

6Fuse

7Hose (High-pressure)

8Compressor

9Condenser

10Pipe (Condenser—Receiver drier)
Tightening torque: N⋅m (kg-m, ft-lb)
T1: 7.4±2.0 (0.75±0.2, 5.4±1.4)
T2: 15±3 (1.5±0.3, 10.8±2.2)
T3: 15±5 (1.5±0.5, 10.8±3.6)
T4: 25±5 (2.5±0.5, 18.1±3.6)
4
4-7COMPONENT PARTS
1. Air Conditioning System

Page 1458 of 3342

2. Evaporator Unit
1. LHD MODEL
B4M0086A
1Thermo control amplifier

2Case upper

3Cooling unit

4Pipe

5Seat

6Expansion valve

7Drain hose

8Case lower

9Resistor

10Resistor bracket
Tightening torque: N⋅m (kg-m, ft-lb)
T1: 7.4±2.0 (0.75±0.2, 5.4±1.4)
T2: 10±3 (1.0±0.3, 7.2±2.2)
T3: 15±5 (1.5±0.5, 10.8±3.6)
T4: 20±5 (2.0±0.5, 14.5±3.6)
5
4-7COMPONENT PARTS
2. Evaporator Unit

Page 1459 of 3342

2. RHD MODEL
B4M0684A
1Thermo control amplifier

2Case upper

3Cooling unit

4Pipe

5Expansion valve

6Drain hose

7Case lower

8Resistor
6
4-7COMPONENT PARTS
2. Evaporator Unit

Page 1460 of 3342

3. Compressor
1. LHD MODEL
B4M0758A
1Alternator bracket

2Alternator

3Alternator bracket nut

4Bracket

5Compressor bracket lower

6Compressor

7Idler pulley ASSY

8Compressor bracket upper
Tightening torque: N⋅m (kg-m, ft-lb)
T1: 23.0±4.4 (2.35±0.45, 17.0±3.3)
T2: 29±4 (3.0±0.4, 21.7±2.9)
T3: 35±4 (3.6±0.4, 26.0±2.9)
7
4-7COMPONENT PARTS
3. Compressor