oil type SUZUKI SWIFT 2007 2.G Service Owner's Guide
Page 980 of 1496
Downloaded from www.Manualslib.com manuals search engine 7B-32 Air Conditioning System: Manual Type
Relief Valve Removal and InstallationS7RS0B7216030
Removal1) Recover refrigerant fr om the A/C system with 
recovery and recycling equipment referring to 
“Recovery” in “Operation Procedure for Refrigerant 
Charge”.
2) Remove relief valve (1) from compressor (2). Installation
Reverse removal procedure nothing the following 
instructions.
• Use new O-ring.
• Apply compressor oil to O-ring.
• Tighten relive valve to the specified torque.
Tightening torque
Relief valve (a):  8 N·m (0.8 kgf-m, 6.0 lb-ft)
• Evacuate and charge the A/C system referring to  “Evacuation” and “Charge” in “Operation Procedure 
for Refrigerant Charge”.
Specifications
Tightening Torque SpecificationsS7RS0B7217001
NOTE
The specified tightening torque is also described in the following.
“Compressor Assembly Components”
 
Reference:
For the tightening torque of fastener not specified in this  section, refer to “Fasteners Information in Section 0A”.
12I4RS0A720048-01
(a)I4RS0A720049-01
Fastening part
Tightening torque
Note
N ⋅mkgf-mlb-ft
Receiver/dryer bolt 10 1.0  7.5  )
Expansion valve mount bolt 3.5 0.35  2.5  )
A/C refrigerant pressure sensor 11 1.1  8.0  )
Armature plate bolt  15 1.5  11.0  )
Relief valve 8 0.8  6.0  )  
Page 981 of 1496
Downloaded from www.Manualslib.com manuals search engine Air Conditioning System: Manual Type 7B-33
Special Tools and Equipment
Recommended Service MaterialS7RS0B7218001
NOTE
Required service material is also described in the following.
“Precautions on Servicing A/C System”
 
Special ToolS7RS0B7218002
Material SUZUKI recommended product or Specification Note
Compressor oil MATSUSHITADEN KI GU10 P/No.: 99000–99015–
00A  )
 /  )
Silicon sealant SUZUKI SILICON SEALANT KE-
347W (100g) P/No.: 99000–34220
 )
09900–06107 09990–86012
Snap ring pliers (opening 
type) Gas leak detector
 )  /  )  /  )  /  ) This kit includes following 
items. 1. Gas leak detector, 
2. Instruction manual, 3. 
Filter, 4. Sensor, 5. Dri-sell 
battery (size D) ) /  )
09991–06310
Armature plate holder
 )  /  )
1 2
3 4
5  
Page 989 of 1496
Downloaded from www.Manualslib.com manuals search engine Air Conditioning System: Automatic Type 7B-41
Cool air does not come 
out or insufficient cooling 
(A/C system normal 
operation)Insufficient or excessive charge of 
refrigerant
Check the amount of refrigerant and system 
for leaks.
Condenser clogged Check condenser referring to “Condenser 
Assembly On-Vehicle Inspection”.
A/C evaporator clogged or frosted Check A/C evaporator and evaporator 
temperature sensor referring to “Evaporator 
Inspection” and “Evaporator Thermistor 
(Evaporator Temperature Sensor) Inspection”.
Evaporator temperature sensor faulty Check evaporator temperature sensor 
referring to “Evaporator Thermistor 
(Evaporator Temperature Sensor) Inspection”.
Expansion valve faulty Check expansion valve referring to “Expansion 
Valve Inspection”.
Desiccant clogged Replace receiver/dryer.
Compressor drive belt loosened or 
broken Adjust or replace drive belt.
Magnet clutch faulty Check magnet clutch. Referring to “Magnet 
Clutch Inspection”.
Compressor faulty Check compressor.
Air in A/C system Replace receiver/dryer, and then perform 
evacuation and charge referring to “Operation 
Procedure for Refrigerant Charge”.
Air leaking from HVAC unit or air duct Repair as necessary.
Heater and ventilation system faulty Check HVAC unit.
Temperature selector faulty Check temperature selector referring to 
“Inspection of HVAC Control Module and Its 
Circuit”.
HVAC control module faulty Check HVAC control module referring to 
“Inspection of HVAC Control Module and Its 
Circuit”.
Temperature control actuator faulty Check temperature control actuator referring to 
“Temperature Control Actuator Inspection”.
Blower motor faulty Check blower motor referring to “Blower Motor 
Inspection in Section 7A”.
Excessive compressor oil in A/C system Drain excessive compressor oil from A/C 
system circuit and compressor.
Cool air does not come 
out only intermittently Wiring connection faulty
Repair as necessary.
Expansion valve faulty Check expansion valve referring to “Expansion 
Valve Inspection”.
Excessive moisture in A/C system Replace receiver/dryer, and then perform 
evacuation and charge referring to “Operation 
Procedure for Refrigerant Charge”.
Magnet clutch faulty Check magnet clutch. Referring to “Magnet 
Clutch Inspection”.
Excessive amount of refrigerant Check the amount of refrigerant.
Cool air comes out only at 
high speed Condenser clogged
Check condenser referring to “Condenser 
Assembly On-Vehicle Inspection”.
Insufficient charge of refrigerant Check the amount of refrigerant and system 
for leaks.
Air in A/C system Replace receiver/dryer, and then perform 
evacuation and charge referring to “Operation 
Procedure for Refrigerant Charge”.
Compressor drive belt loosened or 
broken Adjust or replace drive belt.
Compressor faulty Check compressor.
Condition Possible cause Correction / Reference Item