heating AUDI A4 1995 B5 / 1.G AWM Engine Oxygen Sensor Control Checking Workshop Manual
[x] Cancel search | Manufacturer: AUDI, Model Year: 1995, Model line: A4, Model: AUDI A4 1995 B5 / 1.GPages: 46, PDF Size: 0.3 MB
Page 4 of 46

24-74
Display fields
1 2 3 4
Display group 030: Oxygen sensor status
Display
X X X X X X
Indicated
Oxygen sensor status, bank 1, sensor 1 Oxygen sensor status, bank 2, sensor 1
Functional
range 0 = off
1 = on 0 = off
1 = on
Specified
value 1 1 1 1 1 0
Note
If specified value is not obtained Page 24
-81
If specified value is obtained but there is a malfunction stored in DTC memory Check oxygen
sensor adaptation values and control, Page 24
-75
Significance of 3 digit indications in display group 030 X
X
X
Display fields 1 and 2
X Oxygen sensor control: 0= not active; 1 = active
X Operational readiness of oxygen sensor: 0= not active; 1 = active
X Condition of oxygen sensor heater: 0= not active; 1 = active
Note:
The first field of the 3 digit indication (heating) fluctuates between 0 and 1.
Pa
ge 4 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2
Page 8 of 46

24-78
Display group 032 Display field: 1 / 2
Possible cause
Corrective action
Oxygen sensor adaptation
values below specified
range
Leak in intake area (pressure side between
turbocharger and intake manifold) - Check intake system for leaks and
repair false air Page 24
-68
Oil thinning- Oil change or perform swift country road
test
High oil consumption
Mass Air Flow (MAF) sensor faulty- Mass Air Flow (MAF) sensor, checking
Page 24
-59
Evaporative Emission (EVAP) canister purge
regulator valve remains stuck in open
position - Check Evaporative Emission (EVAP)
canister purge regulator valve Page
24
-114
Fuel pressure too high- Check fuel pressure regulator Page
24
-32
Fuel injector does not close- Check fuel injectors Page 24
-37
.
Oxygen sensor heating faulty
Oxygen sensor faulty- Check oxygen sensor heating Page
24
-89
Pa
ge 8 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2
Page 9 of 46

24-79
Display group 032 Display field: 1 / 2
Possible cause
Corrective action
Oxygen sensor adaptation
values via specified range
False air in intake area- Check intake system for leaks and repair
false air Page 24
-68
Fuel pressure too low- Check fuel pressure regulator Page 24
-32
Mass Air Flow (MAF) sensor faulty- Mass Air Flow (MAF) sensor, checking
Page 24
-59
Oxygen sensor heating faultyOxygen sensor faulty- Check oxygen sensor heating Page 24
-89
Fuel injector does not open or opens
only partially - Check fuel injectors Page 24
-37
.
Evaporative Emission (EVAP)
Canister Purge Regulator Valve sticks - Check Evaporative Emission (EVAP)
canister purge regulator valve Page 24
-114
Pa
ge 9 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2
Page 19 of 46

24-89
Oxygen sensor heating, Oxygen Sensor
(O2S) Heater -Z19- before catalytic
converter, checking
Special Tools and Equipment
VAG1526A
VAG1594A
VAG1598/31
Pa
ge 19 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2
Page 20 of 46

24-90
Test requirements:
Coolant Temperature at least 80 C.
Fuse for oxygen sensor heating OK
Electrical Wiring Diagrams, Troubleshooting &
Component Locations
Test sequence
Note:
Coolant reservoir screws must be removed and coolant reservoir must be
placed to side in order to access the harness connector. The coolant
hoses can remain connected. - Disconnect 6-pin harness connector (black) -2- to Heated Oxygen
Sensor (HO2S) -G39- before catalytic converter.
If specified value is not obtained: - Connect multimeter between terminal 3 and 4 for resistance
measurement.
Specified value at room temperature: 2.5 to 10
Pa
ge 20 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2
Page 22 of 46

24-91
If specified value is obtained:
- Check voltage supply of oxygen sensor
heating.
Checking voltage supply for oxygen sensor
heating
Note:
When the Engine Control Module (ECM) switches oxygen sensor heating
on and off, it may be observed via the function "read measuring value
block", in display group number 041 display field 2.
If there is no voltage: - Connect multimeter between terminal 3 and 4 for voltage
measurement.
- Start engine.
Specification: approx. battery voltage
- Connect multimeter for voltage measurement as follows.Harness connector
Terminal
Measure to
3 (B+) Vehicle Ground (GND)
Pa
ge 22 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2
Page 24 of 46

When the Engine Control Module (ECM) switches oxygen sensor heating
on and off, it may be observed via the function "read measuring value
block", in display group number 041 display field 2.
Pa
ge 24 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2
Page 25 of 46

24-93
- Switch ignition off.
If there is no voltage:
- Connect VAG1598/31 test box at wiring harness
to Engine Control Module (ECM), do not connect
ECM Page 24
-19
.
Electrical Wiring Diagrams, Troubleshooting & Component Locations
If wire connection is OK, but there is no Ground (GND) supply for oxygen
sensor heating: - Check the following wire connection for open circuit:Harness connector
Terminal
VAG1598/31 test box
Socket
4 5
- Repair open circuit if necessary.- Replace Engine Control Module (ECM) Page 24
-22
Pa
ge 25 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2
Page 26 of 46

24-94
Heated Oxygen Sensor (HO2S) and
oxygen sensor control after Three Way
Catalytic Converter (TWC), checking
Note:
The oxygen sensor before catalytic converter
(bank 1, sensor 1) regulates to Lambda 1. If this
oxygen sensor is damaged, e.g. due to soiling or
overheating, the regulation value may have
shifted. Deviations from Lambda 1 are detected
by the oxygen sensor after catalytic converter
(bank 1, sensor 2). If it recognizes the deviations
downward or upward, it influences the regulation
before catalytic converter, generally increasing or
decreasing it respectively.
Pa
ge 26 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2
Page 30 of 46

24-98
Display fields
1 2 3 4
Display group 030: Oxygen sensor status
Display X X X
X X X
Indicated Oxygen sensor status, bank 1, sensor 1
Oxygen sensor status bank 2, sensor 1
Functional range 0 = off
1 = on 0 = off
1 = on
Specified value 1 1 1
1 1 0
Note
If specified value is not obtained Page 24
-107
Significance of 3 digit indications in display group 030 X
X
X
Display fields 1 and 2
X Oxygen sensor control: 0= not active; 1 = active
X Operational readiness of oxygen sensor: 0= not active; 1 = active
X Condition of oxygen sensor heater: 0= not active; 1 = active
Notes:
The first position of the 3 digit indication (heating) fluctuates between 0 and 1.
Oxygen sensor control of oxygen sensor after catalytic converter (B1-S2) is not active without engine load.
Pa
ge 30 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2