01-264
 Test table: display group 3  Read measuring value 
block  3   
 Indicated on display  
60 to 
8000  
1 RPM  0 to 
630  
Nm  
0 to 
630  
Nm  0 to 100  
%    
     
  
Throttle valve angle:  
- If nothing is displayed, press -C- button, select function 02 and check DTC memory. Repair the 
malfunction with the help of the DTC table   page 01
-356
 . 
     
Dissipation torque:  
- If nothing is displayed, press -C- button, select function 02 and check DTC memory. Repair the 
malfunction with the help of the DTC table   page 01
-356
 . 
  
Engine torque:  
- If nothing is displayed, press -C- button, select function 02 and check DTC memory. Repair the malfunction with 
the help of the DTC table   page 01
-356
 . 
Engine speed:  
 
Engine speed is displayed in increments of 60 RPM, starting at 60 RPM. 
- If nothing is displayed, press -C- button, select function 02 and check DTC memory. Repair the malfunction with the help 
of the DTC table   page 01
-356
 . 
Notes:  
Pa
ge 23 of 64 Basic settin
g (scan tool function 04
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.SU02.01.15 
Page 25 of 64

01-265
      
Note:  
     The display group numbers can be selected in 
sequence by pressing buttons <-1 and 3-> on the 
VAG1551 scan tool, or the arrow buttons  and 
 on the VAG1552 mobile scan tool or the arrow 
buttons   and  on the screen of the VAS5051 
tester.      
-  Press -C- button to input display group number 
manually. Read measurin
g value block
Enter display group number XXX
    
Indicated on display:  
-  Press buttons -0-, -0- and -4-.
-  Press -Q- button to confirm input.
Pa
ge 25 of 64 Basic settin
g (scan tool function 04
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.SU02.01.15 
Page 26 of 64

01-266
      
Note:  
     For test table display group 4: 
     
Display group 4 is not occupied for control 
modules with no. 4B0 907 389 without index 
and cannot be selected for these control 
modules by pressing buttons <-1 and 3-> on the 
VAG1551 or by pressing the arrow buttons   
and   on the VAG1552 or via manual input. 
      If an attempt is made to select display group 
number 4:  Function is unknown or can not be performed at the moment.
    
Indicated on display:  
- 
Press  button.
Rapid data transfer 
HELP
Select function XX
    
Indicated on display:  
Bypass display group number 4 or you will be forced to exit the "Read 
measuring value block" function. Press the C-button to do this and then 
select display group number 3 or 5 directly.  
Pa
ge 26 of 64 Basic settin
g (scan tool function 04
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.SU02.01.15 
Page 27 of 64

01-267
 Test table: display group 4  Read measuring value block  
4   
 Indicated on display  
00:00 h   
or  
invalid  Off/on  
not  
used  not  
used    
     
     
     
  
  
EDL shut-off  
 
Electronic Differential Lock (EDL) is deactivated at excessive brake temperature (only EDL). 
Standing time (TIM):  
 
The standing time (TIM) is used to calculate how much the brakes have cooled while the ignition is off. The ABS control 
module -J104- receives the standing time signal from the instrument cluster. 
- If nothing is displayed, press -C- button, select function 02 and check DTC memory. Repair the malfunction with the help 
of the DTC table   page 01
-356
 . 
Invalid:  
 
Battery disconnected or completely discharged
 Open circuit in wire from ABS control module (w/EDL) -J104- to instrument cluster
Note:  
Pa
ge 27 of 64 Basic settin
g (scan tool function 04
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.SU02.01.15 
Page 29 of 64

01-268
      
Note:  
     The display group numbers can be selected in 
sequence by pressing buttons <-1 and 3-> on the 
VAG1551 scan tool, or the arrow buttons  and 
 on the VAG1552 mobile scan tool or the arrow 
buttons   and  on the screen of the VAS5051 
tester.      
-  Press -C- button to input display group number 
manually. Read measurin
g value block
Enter display group number XXX
    
Indicated on display:  
-  Press buttons -0-, -0- and -5-.
-  Press -Q- button to confirm input.
Pa
ge 29 of 64 Basic settin
g (scan tool function 04
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.SU02.01.15 
Page 30 of 64

01-269
      
Note:  
     For display group 5 (005): 
     
To read the display fields for yaw rate and 
transverse acceleration while driving, 
communication between the scan tool and the 
control module must be terminated via the "End 
Output" function   page 01
-16
 . Start the 
engine and reinitiate communication between 
the scan tool and the control module. 
Rapid data transfer 
Q
08 - Read measurin
g value block
    
Indicated on display:  
-  Press buttons -0- and -8- to select "Read measuring value block" 
function 08. 
-  Press -Q- button to confirm input.
Read measurin
g value block
Enter display group number XXX
    
Indicated on display:  
-  Press buttons -0-, -0- and -5-.
-  Press -Q- button to confirm input.
Pa
ge 30 of 64 Basic settin
g (scan tool function 04
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.SU02.01.15 
Page 31 of 64

01-270
 Test table: display group 5  Read measuring value 
block  5   
 Indicated on display  
- 720   
...  
+720   
- 69 
/s ...  
+ 69  /s  
- 41 
bar ...  
+292 
bar  - 25 m/s2 ...  
+ 25 m/s2    
     
  
Transverse acceleration:  
 
Specification with vehicle at standstill:   0....0.7 m/s2 Specification with steering wheel fully turned at a speed of 20 km/h: max.  6.0 m/s2; the 
value of the measured value increases steadily.  Another test for the sensor is located   page 01
-271
 ; Fig.   1
 .
     
Brake pressure:  
 
Specification with brake pedal not depressed:   0....5 bar
  
Rotation rate:  
Specification with vehicle at standstill:   3  /sSpecification with steering wheel fully turned at a vehicle speed of 20 km/h: max.   65  /s; the value of the 
measured value increases steadily. 
Steering angle:  
 
Pa
ge 31 of 64 Basic settin
g (scan tool function 04
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.SU02.01.15 
Page 34 of 64

01-272
      
 
After this, a value of either - 9,8   1 m/s2 or 
+ 9,8   1 m/s2 will be indicated on the scan 
tool display in display group 5 (use the "Read 
measuring value block" function).      
  A plus in front of the number indicates the 
affect on the sensor while driving around a 
left-hand curve. 
     
  A minus in front of the number indicates the 
affect on the sensor while driving around a 
right-hand curve. 
     
  After reinstalling the sensor for transverse 
acceleration -G200- or the combined sensor 
for yaw rate and transverse acceleration, 
tighten the mounting bolts to 5 Nm. Tighten 
the mounting bolts for the control module for 
ultra-sound sensors -J347- to 2 Nm. 
     
Note:  
     Due to an error in the test card 8.0 for the 
VAG1551 scan tool and the test card 5.0 for the 
VAG1552 scan tool, the display for Measuring 
Value Block 5, display group 4 is offset by one 
decimal point. This means, for example, that a 
transverse acceleration value of 9.81m/s2 is 
displayed simply as 0.98 m/s2 . 
Pa
ge 34 of 64 Basic settin
g (scan tool function 04
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.SU02.01.15 
Page 35 of 64

01-273
      
Note:  
     The display group numbers can be selected in 
sequence by pressing buttons <-1 and 3-> on the 
VAG1551 scan tool, or the arrow buttons  and 
 on the VAG1552 mobile scan tool or the arrow 
buttons   and  on the screen of the VAS5051 
tester.      
-  Press -C- button to input display group number 
manually. Read measurin
g value block
Enter display group number XXX
    
Indicated on display:  
-  Press buttons -0-, -0- and -6-.
-  Press -Q- button to confirm input.
Pa
ge 35 of 64 Basic settin
g (scan tool function 04
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.SU02.01.15 
Page 36 of 64

01-274
 Test table: display group 6  Read measuring value 
block  6   
 Indicated on display  
0 volts to 18 
volts  
  on 
or  
off  
on 
or  
off  0 ...  
131071    
     
  
Workshop code:  
 
The workshop code indicates the last workshop that executed the "Login Procedure" (function 
11) under address word 03, "Brake electronics"   page 01
-237
 . 
 If no code is displayed, the "Login Procedure" under address word 03 "Brake Electronics" has 
not been carried out yet. 
     
Voltage at motor for ABS return flow pump:  
 
off   specified value, there is no voltage at the motor for the ABS return flow pump. on  not permitted during "Read measuring value block", there is voltage at the motor for the ABS 
return flow pump. 
- Carry out "Electrical test", steps 12, 23 and 24.
  
ABS solenoid valve relay:  
 
on   specified value, relay was activated by ABS control module -J104- during ignition on. off   not permitted during "Read measuring value block", the relay was not activated during "ignition on".
- Carry out "Electrical test", steps 11 and 22.
Pa
ge 36 of 64 Basic settin
g (scan tool function 04
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.SU02.01.15