01-154
 
Channel 18 Adaptation 1  
Q
- 1 3-  
    
Indicated on display:  
-  Press -Q- button to confirm input.
Channel 18 Adaptation 1  
Q
Store changed value?
    
Indicated on display:  
-  Press -Q- button to confirm input.
Channel 18 Adaptation 1  Changed value is stored
    
Indicated on display:  
- 
End adaptation of the auxiliary heater by pressing the   button.
Pa
ge 91 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic 
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2 
Page 92 of 99

01-155
      
Adaptation of fuel gauge sender resistance 
range  
      This function is used to adjust the fuel gauge 
sender resistance range if the fuel gauge display 
in the instrument cluster does not match the 
actual amount of fuel in the tank.  Rapid data transfer 
HELP
Select function XX
    
Indicated on display  
-  Press -1- and -0- and confirm by pressing the -Q- button.
Rapid data transfer 
Q
10 - Adaptation
    
Indicated on display  
-  Press -Q- button to confirm input.
Adaptation Input channel number XX 
    
Indicated on display:  
-  Press buttons -3- and -0-. 
-  Press -Q- button to confirm input.
Pa
ge 92 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic 
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2 
Page 93 of 99

01-156
 
Channel 30 Adaptation 128  Tank sender  - 1 3-
    
Indicated on display: Adaptation value is displayed, for example 128.  
Notes: 
"128" is the adaptation value for the standard resistance range for the 
fuel gauge sender as set by the factory. The resistance value for the fuel gauge sender resistance range can 
be adjusted by  8 Ohm to give an adaptation value between 120 and 
136. If the value "128" was changed due to a customer complaint, the 
changed value must be transferred when replacing instrument cluster. 
- 
Press  button.
Channel 30 Adaptation 128 Input adaptation value XXXXX
    
Indicated on display:  
Example:  
Desired input value: 132  
Keypad input: 00132  -  Input desired correction value using scan tool keypad, filling initial 
positions with "0" and watch how the display responds. 
Channel 30 Adaptation 128 
Q
Input adaptation value 00132
    
Indicated on display:  
-  Press -Q- button to confirm input.
Pa
ge 93 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic 
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2 
Page 94 of 99

01-157
 
Channel 30 Adaptation 132  
Q
Tank sender  - 1 3-
    
Indicated on display:  
-  Press -Q- button to confirm input.
Channel 30 Adaptation 132  
Q
Store changed value?
    
Indicated on display:  
-  Press -Q- button to confirm input.
Channel 30 Adaptation 132  Changed value is stored
    
Indicated on display:  
-  End adaptation of the fuel gauge sender resistance range by pressing 
the  button. 
Pa
ge 94 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic 
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2 
Page 95 of 99

01-158
      
Adaptation of the engine speed threshold  
      This function is used to adapt the offset value for 
the engine speed threshold to the dynamic oil 
pressure warning.  Rapid data transfer 
HELP
Select function XX
    
Indicated on display  
-  Press -1- and -0- and confirm by pressing the -Q- button.
Rapid data transfer 
Q
10 - Adaptation
    
Indicated on display  
-  Press -Q- button to confirm input.
Adaptation Input channel number XX 
    
Indicated on display:  
-  Press buttons -3- and 5-. 
-  Press -Q- button to confirm input.
Pa
ge 95 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic 
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2 
Page 96 of 99

01-159
 
Channel 35 Adaptation 0 
- 1 3-  
    
Indicated on display: Adaptation value is displayed, for example 0.  
Notes: 
The adaptation value of 0 corresponds to the value set at the factory 
for the oil pressure warning if the oil pressure drops below 1.2 bar at 
1500 rpm. The adaptation can be performed in four steps (0-1000).The adaptation value of "250" changes the engine speed threshold to 
1750 rpm. If the value "0" was changed due to a customer complaint, the 
changed value must be transferred when replacing instrument cluster. 
- 
Press  button.
Channel 35 Adaptation 0 Input adaptation value XXXXX
    
Indicated on display:  
-  Input adaptation value using keypad, filling initial positions with "0", for 
example, 00250. 
Channel 35 Adaptation 0 
Q
Input adaptation value 00250
    
Indicated on display:  
-  Press -Q- button to confirm input.
Pa
ge 96 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic 
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2 
Page 97 of 99

01-160
 
Channel 35 Adaptation 250  
Q
- 1 3-  
    
Indicated on display:  
-  Press -Q- button to confirm input.
Channel 35 Adaptation 250  
Q
Store changed value?
    
Indicated on display:  
-  Press -Q- button to confirm input.
Channel 35 Adaptation 250  Changed value is stored
    
Indicated on display:  
- 
End adaptation of the engine speed threshold by pressing the   
button. 
Pa
ge 97 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic 
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2 
Page 98 of 99

01-161
      
Distance driven since service  
      This function is used to input the distance in 
miles since the last service.  Rapid data transfer 
HELP
Select function XX
    
Indicated on display  
-  Press -1- and -0- and confirm by pressing the -Q- button.
Rapid data transfer 
Q
10 - Adaptation
    
Indicated on display  
-  Press -Q- button to confirm input.
Adaptation Input channel number XX 
    
Indicated on display:  
-  Press buttons -4- and -0-. 
-  Press -Q- button to confirm input.
Channel 40 Adaptation 8  Actual value Insp. in 100 Miles  - 1 3-
    
Indicated on display: The display indicates the number of miles driven 
since the last service (here for example, 8 indicates 800 miles)  
Pa
ge 98 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic 
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2 
Page 99 of 99

01-162
      
Notes:  
     
Input of current specified value is only possible 
in units of 100 miles, therefore indication in 
display also changes in 100 mile units. 
     Observe notes when replacing instrument 
cluster  Page 01
-191
 . 
     
Values can only be input directly using the scan 
tool keypad. 
     