high BMW 750IL 1989 E32 Level Control System Manual
[x] Cancel search | Manufacturer: BMW, Model Year: 1989, Model line: 750il, Model: BMW 750il 1989 E32Pages: 57, PDF Size: 1.89 MB
Page 50 of 57

50
Level Control Systems
Normal
The normal mode is the starting point for the vehicle’s normal operating state. It is obtained
by way of the engine running signal.
Ride level compensation, changing the vehicle’s ride height and filling the accumulator are
possible. The compressor starts up as required.
A narrower tolerance band than that in Pre-mode cab be used because the battery capac-
ity does not have to be protected. The fast filter is used with a narrow tolerance band of
+/- 10mm. In this way, ride level compensation takes place outside a narrow band of 10+/-
10mm. The faster filter allows the system to respond immediately to changes in ride level.
Evaluation and control are performed separately for each wheel.
When a speed signal is recognized, the control unit switches into Drive mode. When the
vehicle is stopped, the control unit remains in Drive mode. The system switches back into
Normal mode when a door or the boot (trunk) lid is also opened. If none of the doors or
the boot lid is opened, the vehicle cannot be loaded or unloaded.
This prevents a control operation happening when the vehicle (for example) is stopped at
traffic lights and the ride height is above the mean axle due to the pitching motion on the
rear axle.
Drive
The Drive mode is activated for E39/E53 single axle air suspension when a speed signal of
>4km/h is recognized. The Drive mode is recognized from >1km/h for the E65/E66 single
axle air suspension and for the E53 twin-axle air suspension system.
Low pass filters are used. In this way, only changes in ride height over a prolonged period
of time (1000 seconds) are corrected. These are merely the changes in ride height, caused
by vehicle compression and a reduction in vehicle mass due to fuel consumption. The high
pass (fast) filter is used during the control operation. The slow filters are recognized at the
end of the control operation. The slow filters are re-initialized at the end of the control oper-
ation. The markedly dynamic height signals caused by uneven road surfaces are filtered
out.
Page 53 of 57

53
Level Control Systems
Operating Principle
Initialization/Reset Performance
When the control unit is powered up after a reset (such as an undervoltage < 4.5 V or by a
load cutoff), different tests and initializations are performed. This system is only enabled
after the tests have been successfully completed and starts to execute the control pro-
grams on a cyclical basis.
Occurring faults are stored and displayed.
Control Sequence
In an ongoing control operation, the high pass filter (fast filter) is always used to prevent the
controlled height from overshooting the nominal value. If a low pass filter (slow filter) were
used to calculate the ride height, brief changes of ride height would be consumed. The
low-pass filter is used while the vehicle is driven. This type of filtering filters out vibrations
which are excited by the road surface.
The high pass filter is used to respond quickly to ride level deviations from setpoint. These
take place while the vehicle is stationary in the event of large load changes.
Both sides of the vehicle are controlled individually, i.e. even the setpoint/actual value com-
parison for both sides is carried out individually. Exception: check for undershooting of the
minimum height in Pre-mode and Kerf mode: consideration of the left and right mean val-
ues in each case.
The following stipulations are applicable here:
Raising before lowering
Activation of all valves with control in the same direction
Individual wheel deactivation
To ensure safe closing of the non-return valve in the air drier, the drain valve is actuated
briefly for 200ms after the control operation has ended.
The permissible ON period of the components is monitored while control up operation are
executed.
Page 54 of 57

54
Level Control Systems
Safety Concept
The safety concept is intended to inhibit any system malfunction, particularly unintentional
control operations, through monitoring of signals and function relevant parameters. If faults
are detected, the system is switched over or shut down depending on the affected com-
ponent. The driver is informed of existing faults via the display. Detected faults are stored
for diagnostic purposes.
In order to ensure high system availability, existing faults, as far as possible, are cleared with
terminal 15 ON. This is done by resetting the fault counter to zero. However, the fault
memory content in the EEPROM is retained and can be read out for diagnostic purposes.
The system is then operational again. The fast troubleshooting helps to detect existing
faults before control operation can take place.
Only lowering is permitted if:
The permissible supply voltage of 9 volts is undershot
The permissible compressor running time of 480 seconds is exceeded.
A reset takes place if the voltage is in the OK range of 9 to 16 volts or after the compres-
sor pause time of 100 seconds has elapsed.
Only raising is permitted if:
The permissible control down period of 40 seconds is exceeded
The reset takes place the next time the vehicle is driven or after the next control up
operation.
No control operation takes place if:
The permissible supply voltage of 16 volts is exceeded
The reset takes place as soon as the voltage is in the OK range.