Downloaded from www.Manualslib.com manuals search engine 490
AIRCONAIRCON
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Changing the filtering/drying cartridge
Tools.
[1]
Charge station :(according to workshop equipment)[2]TORX adaptor: TORX 70 FACOM
[3]Inertia extractor:1671 T Tool kit 4114 T
[4]Endpiece Ø 20 : 1671 T.D20
[5]Set of plugs: ( ).0188.T
[6]Circlip pliers: FACOM
Removing.
Depressurise the aircon circuit, using tool [1].
Remove the grille.At
«a», remove the pin and the plastic cover.
Unclip the condenser at «b»and «c», using a screwdriver.
Tilt the condenser towards the front.
Lift and release the condenser.Clean the area around the cap
(3).
Remove the plastic cap (3), using tool [2].
Remove the safety circlip (4), using tool [6].
Position the tool [3]and[4]in the aperture of the cartridge (5).
Extract the cartridge from the reservoir (6), using tool [3]and [4].
Block the reservoir (6), using tool [5].
C4AP163CC4AP164CC4AP166CC4AP165C
C2 C3 C3 PLURIEL
Downloaded from www.Manualslib.com manuals search engine 491
AIRCON
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Changing the filtering/drying cartridge
Refitting.
Remove the new cartridge from its packaging.
Do not expose the cartridge, the filter and seals to pollutants.
Lightly oil the seals
(compressor oil).
Remove tool [5] from the reservoir (6).
Insert the new cartridge (5)into the reservoir (6).
Refit the safety circlip (4), using tool [6].
Make sure that the circlip (4)is correctly positioned in its location.
WARNING: Not more than 5 minutes should elapse between the removal of
the cartridge (6) from its packaging and its being fitted.
Refit:
The plastic cap (3), using tool [5] Tighten to 1,2 ±0,1 m.daN.
The condenser (reclip, pushing at «b»and «c»).
The plastic cover and the pins at «a».
The grille (2).
The screws (1).
Proceed to:
Recharge the circuit
(see corresponding operation).
Check the operation of the air conditioning (see corresponding operation).
C4AP167CC4AP165CC4AP164CC4AP163C
C2 C3 C3 PLURIEL