DODGE RAM 1500 1998 2.G User Guide FUEL FILLER CAP
DESCRIPTION
The plastic fuel tank filler tube cap is threaded
onto the end of the fuel fill tube. Certain models are
equipped with a 1/4 turn cap.
OPERATION
The loss of any fuel or vap

Page 2575 of 2627

DODGE RAM 1500 1998 2.G User Guide OPERATION
The main purpose of the LDP is to pressurize the
fuel system for leak checking. It closes the EVAP sys-
tem vent to atmospheric pressure so the system can
be pressurized for leak testing. Th

Page 2576 of 2627

DODGE RAM 1500 1998 2.G User Guide LDP AT REST (NOT POWERED)
When the LDP is at rest (no electrical/vacuum) the
diaphragm is allowed to drop down if the internal
(EVAP system) pressure is not greater than the
return spring. The LDP sol

Page 2577 of 2627

DODGE RAM 1500 1998 2.G User Guide PUMPING ACTION
Action : During portions of this test, the PCM uses
the reed switch to monitor diaphragm movement.
The solenoid is only turned on by the PCM after the
reed switch changes from open to c

Page 2578 of 2627

DODGE RAM 1500 1998 2.G User Guide Check the vapor/vacuum lines at the LDP, LDP
filter and EVAP canister purge solenoid for
damage or leaks. If a leak is present, a Diagnos-
tic Trouble Code (DTC) may be set.
(4) Connect electrical con

Page 2583 of 2627

DODGE RAM 1500 1998 2.G User Guide 5.7L V-8
(1) Clean out intake manifold opening.
(2) Check condition of 2 o-rings on PCV valve.
(3) Apply engine oil to 2 o-rings.
(4) Place PCV valve into intake manifold and
rotate 90 degrees clockwi

Page 2584 of 2627

DODGE RAM 1500 1998 2.G User Guide NATURAL VAC LEAK
DETECTION ASSY
DESCRIPTION
Vehicles equipped with NGC engine control mod-
ules use an NVLD pump and system.Vehicles
equipped with JTEC engine control modules use an
LDP (leak detectio

Page 2585 of 2627

DODGE RAM 1500 1998 2.G User Guide The NVLD device is designed with a normally open
vacuum switch, a normally closed solenoid, and a
seal, which is actuated by both the solenoid and a
diaphragm. The NVLD is located on the atmospheric
v

Page 2586 of 2627

DODGE RAM 1500 1998 2.G User Guide INSTALLATION
(1) Install NVLD pump to EVAP canister mount-
ing bracket (snaps on).
(2) Install NVLD filter and bolt to EVAP canister
mounting bracket. Refer to Torque Specifications.
(3) Carefully ins