air conditioning DODGE RAM 2003 Service Manual PDF

DODGE RAM 2003 Service Manual PDF RAM 2003 DODGE DODGE https://www.carmanualsonline.info/img/12/56916/w960_56916-0.png DODGE RAM 2003 Service Manual PDF

Page 2804 of 2895

DODGE RAM 2003  Service Manual PDF (2) Install the screws and snap clips that secure
the upper and lower HVAC housing halves to each
other. Tighten the screws to 2.2 N´m (20 in. lbs.).
(3) Install the blower motor and wheel unit in th

Page 2805 of 2895

DODGE RAM 2003  Service Manual PDF MODE DOOR
REMOVAL - FLOOR - DEFROST DOOR
WARNING: ON VEHICLES EQUIPPED WITH AIR-
BAGS, DISABLE THE AIRBAG SYSTEM BEFORE
ATTEMPTING ANY STEERING WHEEL, STEERING
COLUMN, OR INSTRUMENT PANEL COMPONENT
DI

Page 2807 of 2895

DODGE RAM 2003  Service Manual PDF STANDARD PROCEDURE
STANDARD PROCEDURE - REFRIGERANT
SYSTEM EVACUATE...................51
STANDARD PROCEDURE- REFRIGERANT
RECOVERY..........................52
STANDARD PROCEDURE- REFRIGERANT
SYSTEM CHA

Page 2809 of 2895

DODGE RAM 2003  Service Manual PDF The refrigerant system will remain chemically sta-
ble as long as pure, moisture-free R-134a refrigerant
and refrigerant oil is used. Dirt, moisture, or air can
upset this chemical stability. Operatio

Page 2810 of 2895

DODGE RAM 2003  Service Manual PDF erant system. Refer to the operating instructions sup-
plied by the equipment manufacturer for the proper
care and use of this equipment.
STANDARD PROCEDURE - REFRIGERANT
SYSTEM EVACUATE
WARNING: REVI

Page 2811 of 2895

DODGE RAM 2003  Service Manual PDF nents, caused by condenser air flow restriction or an
overcharge of refrigerant.
OPERATION
OPERATION
The compressor is driven by the engine through an
electric clutch, drive rotor and belt arrangement

Page 2812 of 2895

DODGE RAM 2003  Service Manual PDF FRIGERANT - STANDARD PROCEDURE) and
(Refer to 24 - HEATING & AIR CONDITIONING/
PLUMBING/REFRIGERANT - STANDARD PROCE-
DURE). If the liquid slugging condition continues
replace the accumulator(Refer to

Page 2813 of 2895

DODGE RAM 2003  Service Manual PDF INSTALLATION
INSTALLATION
WARNING: REVIEW THE WARNINGS AND CAU-
TIONS IN THE FRONT OF THIS SECTION BEFORE
PERFORMING THE FOLLOWING OPERATION.
(Refer to 24 - HEATING & AIR CONDITIONING/
PLUMBING - WARN

Page 2814 of 2895

DODGE RAM 2003  Service Manual PDF (7) Evacuate the refrigerant system. (Refer to 24 -
HEATING & AIR CONDITIONING/PLUMBING -
STANDARD PROCEDURE - REFRIGERANT SYS-
TEM EVACUATE)
(8) Charge the refrigerant system. (Refer to 24 -
HEATING

Page 2815 of 2895

DODGE RAM 2003  Service Manual PDF (5) Disconnect the condenser cooling fan electric
connector.
(6) Remove the two nuts that secure the condenser
studs to the upper cross brace. (Fig. 5).
(7) Remove the condenser and fan assembly from