Flashing way of malfuntion code 17 for O2 sensor (3) Each fault code will blink for three times, interval time is 3s, after blinking for the third times, after an
interval of 3s, next fault code will blink. After blinking of all fault codes is finished, they will blink from begining
again. The following diagram shows engine fault warning lamp blinking mode for oxygen sensor fault code 17.5-127Terminal No. Terminal definition
4 Power supply (-)
7 Bus (signal)
16 Power supply (+)Diagnosis connector Notes: use tester cable to connect handheld tester with diagnostic interface, turn ignition switch to ON position,
operate tester, if tester displays that communication is not possible, the vehicle or tester fails.
Inspection diagnosis
1. Check engine fault warning lamp
(1) When ignition switch is turned to ON position and engine does not run, engine warning lamp on
instrument should illuminate.
(2) When engine runs, engine fault warning lamp should go out. If it still illuminates, diagnostic system
detects system fault or abnormity.
2. Use handheld tester to check diagnostic code
(1) Connect handheld tester according to corresponding pin.
(2) Turn ignition switch to ON position, turn on main switch of handheld tester.
(3) Use handheld tester to detect and check diagnostic code, refer to fault diagnostic code table. (For
operation of handheld tester, see instruction manual of handheld tester)
3. Engine fault warning lamp displays fault code through blinking code, so professional may make fault
judgment in case of emergency.
(1)Turn ignition switch to ON position.
(2) Short signal pin (9#) and negative pole (4#) for more than 2. 5s,then disconnect them,detection fault lamp
on dashboard will blink the faults in fault code according to their occurrence sequence.See from terminal outlet
endConnect in jump way over 2.5s and
disconnect
Diagnosis connectorDiagnosis connectorEngine EFI System-
Engine EFI System