load capacity INFINITI FX35 2004 Service Manual
[x] Cancel search | Manufacturer: INFINITI, Model Year: 2004, Model line: FX35, Model: INFINITI FX35 2004Pages: 4449, PDF Size: 99.66 MB
Page 453 of 4449

ATC-24
REFRIGERATION SYSTEM
Revision: 2004 November 2004 FX35/FX45
Operation
1. Operation Control Valve
–By changing high-pressure valve lift amount, built-in compressor control valve executes the following:
Controls high-pressure valve discharge amount.
Changes crankcase pressure in compressor.
Changes angle of wobble (swash) plate.
–Amount of high-pressure valve loft is determined by factors below.
Low-pressure applied to diaphragm
Spring load of set spring
Balance of magnetic force generated in magnet coil
–Electronic control valve (ECV) magnet coil receives electric signal (duty control) from unified meter and A/
C amp. (Auto amp.) Then, magnetic force generated by electric current is changed to control high-pres-
sure valve lift amount.
2. Maximum Cooling
High-pressure valve is closed by magnetic force generated by electric signal sent from unified meter and
A/C amp. At this time, cylinder moves full stroke due to pressure balance between inside crankcase (Pc)
and suction line (Ps).
Under this condition, the wobble (swash) plate is set to the maximum stroke position.
3. Capacity Control
When no electric signal is sent from unified meter and A/C amp. (current: OFF), high-pressure valve is
opened by spring force.
Since suction pressure is low, it makes the suction port close and the discharge port open. Thus, crank-
case pressure becomes high as high-pressure enters the crankcase.
–The force acts around the journal pin near the wobble (swash) plate, and is generated by the pressure dif-
ference before and behind the piston.
–The drive lug and journal pin are located where the piston generates the highest pressure. Piston pres-
sure is between suction pressure Ps and discharge pressure Pd, which is near suction pressure Ps. If
crankcase pressure Pc rises due to capacity control, the force around the journal pin makes the wobble
(swash) plate angle decrease and also the piston stroke decrease. In other words, crankcase pressure
RJIA0851E
Page 1577 of 4449
![INFINITI FX35 2004 Service Manual EC-236
[VQ35DE]
DTC P0138, P0158 HO2S2
Revision: 2004 November 2004 FX35/FX45
DTC P0138, P0158 HO2S2PFP:226A0
Component DescriptionABS006OH
The heated oxygen sensor 2, after three way catalyst 1, moni INFINITI FX35 2004 Service Manual EC-236
[VQ35DE]
DTC P0138, P0158 HO2S2
Revision: 2004 November 2004 FX35/FX45
DTC P0138, P0158 HO2S2PFP:226A0
Component DescriptionABS006OH
The heated oxygen sensor 2, after three way catalyst 1, moni](/img/42/57021/w960_57021-1576.png)
EC-236
[VQ35DE]
DTC P0138, P0158 HO2S2
Revision: 2004 November 2004 FX35/FX45
DTC P0138, P0158 HO2S2PFP:226A0
Component DescriptionABS006OH
The heated oxygen sensor 2, after three way catalyst 1, monitors the
oxygen level in the exhaust gas on each bank.
Even if switching characteristics of the heated oxygen sensor 1 are
shifted, the air-fuel ratio is controlled to stoichiometric, by the signal
from the heated oxygen sensor 2.
This sensor is made of ceramic zirconia. The zirconia generates volt-
age from approximately 1V in richer conditions to 0V in leaner condi-
tions.
Under normal conditions the heated oxygen sensor 2 is not used for
engine control operation.
CONSULT-II Reference Value in Data Monitor ModeABS006OI
Specification data are reference values.
On Board Diagnosis LogicABS006OJ
The heated oxygen sensor 2 has a much longer switching time
between rich and lean than the heated oxygen sensor 1. The oxygen
storage capacity of the three way catalyst 1 causes the longer
switching time. To judge the malfunctions of heated oxygen sensor
2, ECM monitors whether the voltage is unusually high during the
various driving condition such as fuel-cut.
SEF327R
MONITOR ITEM CONDITION SPECIFICATION
HO2S2 (B1)
HO2S2 (B2)
Warm-up condition
After keeping engine speed
between 3,500 and 4,000 rpm for
1 minute and at idle for 1 minute
under no load.Revving engine from idle to 3,000 rpm
quickly.0 - 0.3V ←→ Approx. 0.6 -
1.0V
HO2S2 MNTR (B1)
HO2S2 MNTR (B2)LEAN ←→ RICH
SEF305UA
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0138
0138
(Bank 1)
Heated oxygen sensor
2 circuit high voltageAn excessively high voltage from the sensor is
sent to ECM.
Harness or connectors
(The sensor circuit is open or shorted)
Heated oxygen sensor 2 P0158
0158
(Bank 2)
Page 1586 of 4449
![INFINITI FX35 2004 Service Manual DTC P0139, P0159 HO2S2
EC-245
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0139, P0159 HO2S2PFP:226A0
Component DescriptionABS006OP
The heated oxygen sensor 2, after INFINITI FX35 2004 Service Manual DTC P0139, P0159 HO2S2
EC-245
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0139, P0159 HO2S2PFP:226A0
Component DescriptionABS006OP
The heated oxygen sensor 2, after](/img/42/57021/w960_57021-1585.png)
DTC P0139, P0159 HO2S2
EC-245
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0139, P0159 HO2S2PFP:226A0
Component DescriptionABS006OP
The heated oxygen sensor 2, after three way catalyst 1, monitors the
oxygen level in the exhaust gas on each bank.
Even if switching characteristics of the heated oxygen sensor 1 are
shifted, the air-fuel ratio is controlled to stoichiometric, by the signal
from the heated oxygen sensor 2.
This sensor is made of ceramic zirconia. The zirconia generates volt-
age from approximately 1V in richer conditions to 0V in leaner condi-
tions.
Under normal conditions the heated oxygen sensor 2 is not used for
engine control operation.
CONSULT-II Reference Value in Data Monitor ModeABS006OQ
Specification data are reference values.
On Board Diagnosis LogicABS006OR
The heated oxygen sensor 2 has a much longer switching time
between rich and lean than the heated oxygen sensor 1. The oxygen
storage capacity before the three way catalyst 1 causes the longer
switching time. To judge the malfunctions of heated oxygen sensor
2, ECM monitors whether the switching response of the sensor's
voltage is faster than specified during the various driving condition
such as fuel-cut.
SEF327R
MONITOR ITEM CONDITION SPECIFICATION
HO2S2 (B1)
HO2S2 (B2)
Warm-up condition
After keeping engine speed
between 3,500 and 4,000 rpm for
1 minute and at idle for 1 minute
under no load.Revving engine from idle to 3,000 rpm
quickly.0 - 0.3V ←→ Approx. 0.6 -
1.0V
HO2S2 MNTR (B1)
HO2S2 MNTR (B2)LEAN ←→ RICH
SEF302U
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0139
0139
(Bank 1)
Heated oxygen sensor
2 circuit slow responseIt takes more time for the sensor to respond
between rich and lean than the specified time.
Harness or connectors
(The sensor circuit is open or shorted)
Heated oxygen sensor 2
Fuel pressure
Fuel injector
Intake air leaks P0159
0159
(Bank 2)
Page 1657 of 4449
![INFINITI FX35 2004 Service Manual EC-316
[VQ35DE]
DTC P0420, P0430 THREE WAY CATALYST FUNCTION
Revision: 2004 November 2004 FX35/FX45
DTC P0420, P0430 THREE WAY CATALYST FUNCTIONPFP:20905
On Board Diagnosis LogicABS006QH
The ECM monit INFINITI FX35 2004 Service Manual EC-316
[VQ35DE]
DTC P0420, P0430 THREE WAY CATALYST FUNCTION
Revision: 2004 November 2004 FX35/FX45
DTC P0420, P0430 THREE WAY CATALYST FUNCTIONPFP:20905
On Board Diagnosis LogicABS006QH
The ECM monit](/img/42/57021/w960_57021-1656.png)
EC-316
[VQ35DE]
DTC P0420, P0430 THREE WAY CATALYST FUNCTION
Revision: 2004 November 2004 FX35/FX45
DTC P0420, P0430 THREE WAY CATALYST FUNCTIONPFP:20905
On Board Diagnosis LogicABS006QH
The ECM monitors the switching frequency ratio of heated oxygen sensors 1 and 2.
A three way catalyst 1 with high oxygen storage capacity will indicate a low switching frequency of heated oxy-
gen sensor 2. As oxygen storage capacity decreases, the heated oxygen sensor 2 switching frequency will
increase.
When the frequency ratio of heated oxygen sensors 1 and 2 approaches a specified limit value, the three way
catalyst 1 malfunction is diagnosed.
DTC Confirmation ProcedureABS006QI
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
WITH CONSULT-II
TESTING CONDITION:
Do not hold engine speed for more than the specified minutes below.
1. Turn ignition switch ON and select “DATA MONITOR” mode with
CONSULT-II.
2. Start engine and warm it up to the normal operating tempera-
ture.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Start engine and keep the engine speed between 3,500 and
4,000 rpm for at least 1 minute under no load.
5. Let engine idle for 1 minute.
6. Make sure that “COOLAN TEMP/S” indicates more than 70°C
(158°F).
If not, warm up engine and go to next step when “COOLAN
TEMP/S” indication reaches to 70°C (158°F).
7. Open engine hood.
PBIB1166E
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0420
0420
(Bank 1)
Catalyst system effi-
ciency below threshold
Three way catalyst 1 does not operate prop-
erly.
Three way catalyst 1 does not have enough
oxygen storage capacity.
Three way catalyst 1
Exhaust tube
Intake air leaks
Fuel injector
Fuel injector leaks
Spark plug
Improper ignition timing P0430
0430
(Bank 2)
SEF189Y
Page 1787 of 4449
![INFINITI FX35 2004 Service Manual EC-446
[VQ35DE]
DTC P1146, P1166 HO2S2
Revision: 2004 November 2004 FX35/FX45
DTC P1146, P1166 HO2S2PFP:226A0
Component DescriptionABS006UE
The heated oxygen sensor 2, after three way catalyst 1, moni INFINITI FX35 2004 Service Manual EC-446
[VQ35DE]
DTC P1146, P1166 HO2S2
Revision: 2004 November 2004 FX35/FX45
DTC P1146, P1166 HO2S2PFP:226A0
Component DescriptionABS006UE
The heated oxygen sensor 2, after three way catalyst 1, moni](/img/42/57021/w960_57021-1786.png)
EC-446
[VQ35DE]
DTC P1146, P1166 HO2S2
Revision: 2004 November 2004 FX35/FX45
DTC P1146, P1166 HO2S2PFP:226A0
Component DescriptionABS006UE
The heated oxygen sensor 2, after three way catalyst 1, monitors the
oxygen level in the exhaust gas on each bank.
Even if switching characteristics of the heated oxygen sensor 1 are
shifted, the air-fuel ratio is controlled to stoichiometric, by the signal
from the heated oxygen sensor 2.
This sensor is made of ceramic zirconia. The zirconia generates volt-
age from approximately 1V in richer conditions to 0V in leaner condi-
tions.
Under normal conditions the heated oxygen sensor 2 is not used for
engine control operation.
CONSULT-II Reference Value in Data Monitor ModeABS006UF
Specification data are reference values.
On Board Diagnosis LogicABS006UG
The heated oxygen sensor 2 has a much longer switching time
between rich and lean than the heated oxygen sensor 1. The oxygen
storage capacity of the three way catalyst 1 causes the longer
switching time. To judge the malfunctions of heated oxygen sensor
2, ECM monitors whether the minimum voltage of sensor is suffi-
ciently low during the various driving condition such as fuel-cut.
SEF327R
MONITOR ITEM CONDITION SPECIFICATION
HO2S2 (B1)
HO2S2 (B2)
Warm-up condition
After keeping engine speed
between 3,500 and 4,000 rpm for
1 minute and at idle for 1 minute
under no load.Revving engine from idle to 3,000 rpm
quickly.0 - 0.3V ←→ Approx. 0.6 -
1.0V
HO2S2 MNTR (B1)
HO2S2 MNTR (B2)LEAN ←→ RICH
SEF972Z
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P1146
1146
(Bank 1)Heated oxygen sensor
2 minimum voltage
monitoringThe minimum voltage from the sensor is not
reached to the specified voltage.
Harness or connectors
(The sensor circuit is open or shorted)
Heated oxygen sensor 2
Fuel pressure
Fuel injector P1166
1166
(Bank 2)
Page 1798 of 4449
![INFINITI FX35 2004 Service Manual DTC P1147, P1167 HO2S2
EC-457
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P1147, P1167 HO2S2PFP:226A0
Component DescriptionABS006UN
The heated oxygen sensor 2, after INFINITI FX35 2004 Service Manual DTC P1147, P1167 HO2S2
EC-457
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P1147, P1167 HO2S2PFP:226A0
Component DescriptionABS006UN
The heated oxygen sensor 2, after](/img/42/57021/w960_57021-1797.png)
DTC P1147, P1167 HO2S2
EC-457
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P1147, P1167 HO2S2PFP:226A0
Component DescriptionABS006UN
The heated oxygen sensor 2, after three way catalyst 1, monitors the
oxygen level in the exhaust gas on each bank.
Even if switching characteristics of the heated oxygen sensor 1 are
shifted, the air-fuel ratio is controlled to stoichiometric, by the signal
from the heated oxygen sensor 2.
This sensor is made of ceramic zirconia. The zirconia generates volt-
age from approximately 1V in richer conditions to 0V in leaner condi-
tions.
Under normal conditions the heated oxygen sensor 2 is not used for
engine control operation.
CONSULT-II Reference Value in Data Monitor ModeABS006UO
Specification data are reference values.
On Board Diagnosis LogicABS006UP
The heated oxygen sensor 2 has a much longer switching time
between rich and lean than the heated oxygen sensor 1. The oxygen
storage capacity of the three way catalyst 1 causes the longer
switching time. To judge the malfunctions of heated oxygen sensor
2, ECM monitors whether the maximum voltage of the sensor is suf-
ficiently high during the various driving condition such as fuel-cut.
SEF327R
MONITOR ITEM CONDITION SPECIFICATION
HO2S2 (B1)
HO2S2 (B2)
Warm-up condition
After keeping engine speed
between 3,500 and 4,000 rpm for
1 minute and at idle for 1 minute
under no load.Revving engine from idle to 3,000 rpm
quickly.0 - 0.3V ←→ Approx. 0.6 -
1.0V
HO2S2 MNTR (B1)
HO2S2 MNTR (B2)LEAN ←→ RICH
PBIB0820E
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P1147
11 4 7
(Bank 1)
Heated oxygen sensor
2 maximum voltage
monitoringThe maximum voltage from the sensor is not
reached to the specified voltage.
Harness or connectors
(The sensor circuit is open or shorted)
Heated oxygen sensor 2
Fuel pressure
Fuel injector
Intake air leaks P1167
11 6 7
(Bank 2)
Page 2235 of 4449
![INFINITI FX35 2004 Service Manual EC-894
[VK45DE]
DTC P0138, P0158 HO2S2
Revision: 2004 November 2004 FX35/FX45
DTC P0138, P0158 HO2S2PFP:226A0
Component DescriptionABS00C3D
The heated oxygen sensor 2, after three way catalyst (manifo INFINITI FX35 2004 Service Manual EC-894
[VK45DE]
DTC P0138, P0158 HO2S2
Revision: 2004 November 2004 FX35/FX45
DTC P0138, P0158 HO2S2PFP:226A0
Component DescriptionABS00C3D
The heated oxygen sensor 2, after three way catalyst (manifo](/img/42/57021/w960_57021-2234.png)
EC-894
[VK45DE]
DTC P0138, P0158 HO2S2
Revision: 2004 November 2004 FX35/FX45
DTC P0138, P0158 HO2S2PFP:226A0
Component DescriptionABS00C3D
The heated oxygen sensor 2, after three way catalyst (manifold),
monitors the oxygen level in the exhaust gas on each bank.
Even if switching characteristics of the heated oxygen sensor 1 are
shifted, the air-fuel ratio is controlled to stoichiometric, by the signal
from the heated oxygen sensor 2.
This sensor is made of ceramic zirconia. The zirconia generates volt-
age from approximately 1V in richer conditions to 0V in leaner condi-
tions.
Under normal conditions the heated oxygen sensor 2 is not used for
engine control operation.
CONSULT-II Reference Value in Data Monitor ModeABS00C3E
Specification data are reference values.
On Board Diagnosis LogicABS00C3F
The heated oxygen sensor 2 has a much longer switching time
between rich and lean than the heated oxygen sensor 1. The oxygen
storage capacity of the three way catalyst (manifold) causes the
longer switching time. To judge the malfunctions of heated oxygen
sensor 2, ECM monitors whether the voltage is unusually high during
the various driving condition such as fuel-cut.
SEF327R
MONITOR ITEM CONDITION SPECIFICATION
HO2S2 (B1)
HO2S2 (B2)
Warm-up condition
After keeping engine speed
between 3,500 and 4,000 rpm for
1 minute and at idle for 1 minute
under no loadRevving engine from idle to 3,000 rpm
quickly0 - 0.3V ←→ Approx. 0.6 -
1.0V
HO2S2 MNTR (B1)
HO2S2 MNTR (B2)LEAN ←→ RICH
PBIB1848E
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0138
0138
(Bank 1)
Heated oxygen sensor
2 circuit high voltageAn excessively high voltage from the sensor is
sent to ECM.
Harness or connectors
(The sensor circuit is open or shorted)
Heated oxygen sensor 2 P0158
0158
(Bank 2)
Page 2244 of 4449
![INFINITI FX35 2004 Service Manual DTC P0139, P0159 HO2S2
EC-903
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0139, P0159 HO2S2PFP:226A0
Component DescriptionABS00C3L
The heated oxygen sensor 2, after INFINITI FX35 2004 Service Manual DTC P0139, P0159 HO2S2
EC-903
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0139, P0159 HO2S2PFP:226A0
Component DescriptionABS00C3L
The heated oxygen sensor 2, after](/img/42/57021/w960_57021-2243.png)
DTC P0139, P0159 HO2S2
EC-903
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0139, P0159 HO2S2PFP:226A0
Component DescriptionABS00C3L
The heated oxygen sensor 2, after three way catalyst (manifold),
monitors the oxygen level in the exhaust gas on each bank.
Even if switching characteristics of the heated oxygen sensor 1 are
shifted, the air-fuel ratio is controlled to stoichiometric, by the signal
from the heated oxygen sensor 2.
This sensor is made of ceramic zirconia. The zirconia generates volt-
age from approximately 1V in richer conditions to 0V in leaner condi-
tions.
Under normal conditions the heated oxygen sensor 2 is not used for
engine control operation.
CONSULT-II Reference Value in Data Monitor ModeABS00C3M
Specification data are reference values.
On Board Diagnosis LogicABS00C3N
The heated oxygen sensor 2 has a much longer switching time
between rich and lean than the heated oxygen sensor 1. The oxygen
storage capacity of the three way catalyst (manifold) causes the
longer switching time. To judge the malfunctions of heated oxygen
sensor 2, ECM monitors whether the switching response of the sen-
sor's voltage is faster than specified during the various driving condi-
tion such as fuel-cut.
SEF327R
MONITOR ITEM CONDITION SPECIFICATION
HO2S2 (B1)
HO2S2 (B2)
Warm-up condition
After keeping engine speed
between 3,500 and 4,000 rpm for
1 minute and at idle for 1 minute
under no loadRevving engine from idle to 3,000 rpm
quickly0 - 0.3V ←→ Approx. 0.6 -
1.0V
HO2S2 MNTR (B1)
HO2S2 MNTR (B2)LEAN ←→ RICH
SEF302U
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0139
0139
(Bank 1)
Heated oxygen sensor
2 circuit slow responseIt takes more time for the sensor to respond
between rich and lean than the specified time.
Harness or connectors
(The sensor circuit is open or shorted)
Heated oxygen sensor 2
Fuel pressure
Fuel injector
Intake air leaks P0159
0159
(Bank 2)
Page 2312 of 4449
![INFINITI FX35 2004 Service Manual DTC P0420, P0430 THREE WAY CATALYST FUNCTION
EC-971
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0420, P0430 THREE WAY CATALYST FUNCTIONPFP:20905
On Board Diagnosis L INFINITI FX35 2004 Service Manual DTC P0420, P0430 THREE WAY CATALYST FUNCTION
EC-971
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0420, P0430 THREE WAY CATALYST FUNCTIONPFP:20905
On Board Diagnosis L](/img/42/57021/w960_57021-2311.png)
DTC P0420, P0430 THREE WAY CATALYST FUNCTION
EC-971
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0420, P0430 THREE WAY CATALYST FUNCTIONPFP:20905
On Board Diagnosis LogicABS00C5D
The ECM monitors the switching frequency ratio of heated oxygen
sensors 1 and 2.
A three way catalyst (manifold) with high oxygen storage capacity
will indicate a low switching frequency of heated oxygen sensor 2.
As oxygen storage capacity decreases, the heated oxygen sensor 2
switching frequency will increase.
When the frequency ratio of heated oxygen sensors 1 and 2
approaches a specified limit value, the three way catalyst (manifold)
malfunction is diagnosed.
DTC Confirmation ProcedureABS00C5E
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
WITH CONSULT-II
TESTING CONDITION:
Do not hold engine speed for more than the specified minutes below.
1. Turn ignition switch ON and select “DATA MONITOR” mode with
CONSULT-II.
2. Start engine and warm it up to the normal operating tempera-
ture.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Start engine and keep the engine speed between 3,500 and
4,000 rpm for at least 1 minute under no load.
5. Let engine idle for 1 minute.
6. Make sure that “COOLAN TEMP/S” indicates more than 70°C
(158°F).
If not, warm up engine and go to next step when “COOLAN
TEMP/S” indication reaches to 70°C (158°F).
7. Open engine hood.
SEF484YF
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0420
0420
(Bank 1)
Catalyst system effi-
ciency below threshold
Three way catalyst (manifold) does not oper-
ate properly.
Three way catalyst (manifold) does not have
enough oxygen storage capacity.
Three way catalyst (manifold)
Exhaust tube
Intake air leaks
Fuel injector
Fuel injector leaks
Spark plug
Improper ignition timing P0430
0430
(Bank 2)
SEF189Y
Page 2457 of 4449
![INFINITI FX35 2004 Service Manual EC-1116
[VK45DE]
DTC P1146, P1166 HO2S2
Revision: 2004 November 2004 FX35/FX45
DTC P1146, P1166 HO2S2PFP:226A0
Component DescriptionABS00C9W
The heated oxygen sensor 2, after three way catalyst (manif INFINITI FX35 2004 Service Manual EC-1116
[VK45DE]
DTC P1146, P1166 HO2S2
Revision: 2004 November 2004 FX35/FX45
DTC P1146, P1166 HO2S2PFP:226A0
Component DescriptionABS00C9W
The heated oxygen sensor 2, after three way catalyst (manif](/img/42/57021/w960_57021-2456.png)
EC-1116
[VK45DE]
DTC P1146, P1166 HO2S2
Revision: 2004 November 2004 FX35/FX45
DTC P1146, P1166 HO2S2PFP:226A0
Component DescriptionABS00C9W
The heated oxygen sensor 2, after three way catalyst (manifold),
monitors the oxygen level in the exhaust gas on each bank.
Even if switching characteristics of the heated oxygen sensor 1 are
shifted, the air-fuel ratio is controlled to stoichiometric, by the signal
from the heated oxygen sensor 2.
This sensor is made of ceramic zirconia. The zirconia generates volt-
age from approximately 1V in richer conditions to 0V in leaner condi-
tions.
Under normal conditions the heated oxygen sensor 2 is not used for
engine control operation.
CONSULT-II Reference Value in Data Monitor ModeABS00C9X
Specification data are reference values.
On Board Diagnosis LogicABS00C9Y
The heated oxygen sensor 2 has a much longer switching time
between rich and lean than the heated oxygen sensor 1. The oxygen
storage capacity of the three way catalyst (manifold) causes the
longer switching time. To judge the malfunctions of heated oxygen
sensor 2, ECM monitors whether the minimum voltage of sensor is
sufficiently low during the various driving condition such as fuel-cut.
SEF327R
MONITOR ITEM CONDITION SPECIFICATION
HO2S2 (B1)
HO2S2 (B2)
Warm-up condition
After keeping engine speed
between 3,500 and 4,000 rpm for
1 minute and at idle for 1 minute
under no loadRevving engine from idle to 3,000 rpm
quickly0 - 0.3V ←→ Approx. 0.6 -
1.0V
HO2S2 MNTR (B1)
HO2S2 MNTR (B2)LEAN ←→ RICH
SEF972Z
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P1146
1146
(Bank 1)Heated oxygen sensor
2 minimum voltage
monitoringThe minimum voltage from the sensor is not
reached to the specified voltage.
Harness or connectors
(The sensor circuit is open or shorted)
Heated oxygen sensor 2
Fuel pressure
Fuel injector P1166
1166
(Bank 2)