fuel INFINITI FX35 2004 Service Manual
[x] Cancel search | Manufacturer: INFINITI, Model Year: 2004, Model line: FX35, Model: INFINITI FX35 2004Pages: 4449, PDF Size: 99.66 MB
Page 1546 of 4449
![INFINITI FX35 2004 Service Manual DTC P0132, P0152 HO2S1
EC-205
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0132, P0152 HO2S1PFP:22690
Component DescriptionABS006NR
The heated oxygen sensor 1 is plac INFINITI FX35 2004 Service Manual DTC P0132, P0152 HO2S1
EC-205
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0132, P0152 HO2S1PFP:22690
Component DescriptionABS006NR
The heated oxygen sensor 1 is plac](/img/42/57021/w960_57021-1545.png)
DTC P0132, P0152 HO2S1
EC-205
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0132, P0152 HO2S1PFP:22690
Component DescriptionABS006NR
The heated oxygen sensor 1 is placed into the exhaust manifold. It
detects the amount of oxygen in the exhaust gas compared to the
outside air. The heated oxygen sensor 1 has a closed-end tube
made of ceramic zirconia. The zirconia generates voltage from
approximately 1V in richer conditions to 0V in leaner conditions. The
heated oxygen sensor 1 signal is sent to the ECM. The ECM adjusts
the injection pulse duration to achieve the ideal air-fuel ratio. The
ideal air-fuel ratio occurs near the radical change from 1 to 0V.
CONSULT-II Reference Value in Data Monitor ModeABS006NS
Specification data are reference values.
On Board Diagnosis LogicABS006NT
To judge the malfunction, the diagnosis checks that the heated oxy-
gen sensor 1 output is not inordinately high.
SEF463R
SEF288D
MONITOR ITEM CONDITION SPECIFICATION
HO2S1 (B1)
HO2S1 (B2)
Engine: After warming up Maintaining engine speed at 2,000 rpm0 - 0.3V ←→ Approx. 0.6 - 1.0V
HO2S1 MNTR (B1)
HO2S1 MNTR (B2)LEAN ←→ RICH
Changes more than 5 times dur-
ing 10 seconds.
SEF301UA
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0132
0132
(Bank 1)
Heated oxygen sensor
1 circuit high voltageAn excessively high voltage from the sensor is
sent to ECM.
Harness or connectors
(The sensor circuit is open or shorted)
Heated oxygen sensor 1 P0152
0152
(Bank 2)
Page 1555 of 4449
![INFINITI FX35 2004 Service Manual EC-214
[VQ35DE]
DTC P0133, P0153 HO2S1
Revision: 2004 November 2004 FX35/FX45
DTC P0133, P0153 HO2S1PFP:22690
Component DescriptionABS006NZ
The heated oxygen sensor 1 is placed into the exhaust manifo INFINITI FX35 2004 Service Manual EC-214
[VQ35DE]
DTC P0133, P0153 HO2S1
Revision: 2004 November 2004 FX35/FX45
DTC P0133, P0153 HO2S1PFP:22690
Component DescriptionABS006NZ
The heated oxygen sensor 1 is placed into the exhaust manifo](/img/42/57021/w960_57021-1554.png)
EC-214
[VQ35DE]
DTC P0133, P0153 HO2S1
Revision: 2004 November 2004 FX35/FX45
DTC P0133, P0153 HO2S1PFP:22690
Component DescriptionABS006NZ
The heated oxygen sensor 1 is placed into the exhaust manifold. It
detects the amount of oxygen in the exhaust gas compared to the
outside air. The heated oxygen sensor 1 has a closed-end tube
made of ceramic zirconia. The zirconia generates voltage from
approximately 1V in richer conditions to 0V in leaner conditions. The
heated oxygen sensor 1 signal is sent to the ECM. The ECM adjusts
the injection pulse duration to achieve the ideal air-fuel ratio. The
ideal air-fuel ratio occurs near the radical change from 1 to 0V.
CONSULT-II Reference Value in Data Monitor ModeABS006O0
Specification data are reference values.
On Board Diagnosis LogicABS006O1
To judge the malfunction of heated oxygen sensor 1, this diagnosis
measures response time of heated oxygen sensor 1 signal. The time
is compensated by engine operating (speed and load), fuel feedback
control constant, and heated oxygen sensor 1 temperature index.
Judgment is based on whether the compensated time (heated oxy-
gen sensor 1 cycling time index) is inordinately long or not.
SEF463R
SEF288D
MONITOR ITEM CONDITION SPECIFICATION
HO2S1 (B1)
HO2S1 (B2)
Engine: After warming up Maintaining engine speed at 2,000 rpm0 - 0.3V ←→ Approx. 0.6 - 1.0V
HO2S1 MNTR (B1)
HO2S1 MNTR (B2)LEAN ←→ RICH
Changes more than 5 times during
10 seconds.
SEF010V
Page 1556 of 4449
![INFINITI FX35 2004 Service Manual DTC P0133, P0153 HO2S1
EC-215
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC Confirmation ProcedureABS006O2
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If DTC C INFINITI FX35 2004 Service Manual DTC P0133, P0153 HO2S1
EC-215
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC Confirmation ProcedureABS006O2
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If DTC C](/img/42/57021/w960_57021-1555.png)
DTC P0133, P0153 HO2S1
EC-215
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC Confirmation ProcedureABS006O2
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Always perform at a temperature above −10°C (14°F).
Before performing the following procedure, confirm that battery voltage is more than 11V at idle.
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Stop engine and wait at least 10 seconds.
3. Turn ignition switch ON and select “HO2S1 (B1) P0133” or “HO2S1 (B2) P0153” of “HO2S1” in “DTC
WORK SUPPORT” mode with CONSULT-II.
4. Touch “START”.
5. Start engine and let it idle for at least 3 minutes.
NOTE:
Never raise engine speed above 3,600 rpm after this step. If
the engine speed limit is exceeded, return to step 5.
6. When the following conditions are met, “TESTING” will be dis-
played on the CONSULT-II screen. Maintain the conditions con-
tinuously until “TESTING” changes to “COMPLETED”. (It will
take approximately 20 to 50 seconds.)
If “TESTING” is not displayed after 5 minutes, retry from
step 2.
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0133
0133
(Bank 1)
Heated oxygen sensor
1 circuit slow responseThe response of the voltage signal from the
sensor takes more than the specified time.
Harness or connectors
(The sensor circuit is open or shorted)
Heated oxygen sensor 1
Fuel pressure
Injector
Intake air leaks
Exhaust gas leaks
PCV valve
Mass air flow sensor P0153
0153
(Bank 2)
SEF338Z
ENG SPEED 1,000 - 3,100 rpm
Vehicle speed More than 80 km/h (50 MPH)
B/FUEL SCHDL 2.0 - 17.0 msec
Selector lever Suitable position
SEF339Z
Page 1567 of 4449
![INFINITI FX35 2004 Service Manual EC-226
[VQ35DE]
DTC P0134, P0154 HO2S1
Revision: 2004 November 2004 FX35/FX45
DTC P0134, P0154 HO2S1PFP:22690
Component DescriptionABS006O8
The heated oxygen sensor 1 is placed into the exhaust manifo INFINITI FX35 2004 Service Manual EC-226
[VQ35DE]
DTC P0134, P0154 HO2S1
Revision: 2004 November 2004 FX35/FX45
DTC P0134, P0154 HO2S1PFP:22690
Component DescriptionABS006O8
The heated oxygen sensor 1 is placed into the exhaust manifo](/img/42/57021/w960_57021-1566.png)
EC-226
[VQ35DE]
DTC P0134, P0154 HO2S1
Revision: 2004 November 2004 FX35/FX45
DTC P0134, P0154 HO2S1PFP:22690
Component DescriptionABS006O8
The heated oxygen sensor 1 is placed into the exhaust manifold. It
detects the amount of oxygen in the exhaust gas compared to the
outside air. The heated oxygen sensor 1 has a closed-end tube
made of ceramic zirconia. The zirconia generates voltage from
approximately 1V in richer conditions to 0V in leaner conditions. The
heated oxygen sensor 1 signal is sent to the ECM. The ECM adjusts
the injection pulse duration to achieve the ideal air-fuel ratio. The
ideal air-fuel ratio occurs near the radical change from 1 to 0V.
CONSULT-II Reference Value in Data Monitor ModeABS006O9
Specification data are reference values.
On Board Diagnosis LogicABS006OA
Under the condition in which the heated oxygen sensor 1 signal is
not input, the ECM circuits will read a continuous approximately
0.3V. Therefore, for this diagnosis, the time that output voltage is
within 200 to 400 mV range is monitored, and the diagnosis checks
that this time is not inordinately long.
SEF463R
SEF288D
MONITOR ITEM CONDITION SPECIFICATION
HO2S1 (B1)
HO2S1 (B2)
Engine: After warming up Maintaining engine speed at 2,000 rpm0 - 0.3V ←→ Approx. 0.6 -
1.0V
HO2S1 MNTR (B1)
HO2S1 MNTR (B2)LEAN ←→ RICH
Changes more than 5 times
during 10 seconds.
SEF237U
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0134
0134
(Bank 1)Heated oxygen sensor
1 circuit no activity
detectedThe voltage from the sensor is constantly
approx. 0.3V.
Harness or connectors
(The sensor circuit is open or shorted)
Heated oxygen sensor 1 P0154
0154
(Bank 2)
Page 1568 of 4449
![INFINITI FX35 2004 Service Manual DTC P0134, P0154 HO2S1
EC-227
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC Confirmation ProcedureABS006OB
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If DTC C INFINITI FX35 2004 Service Manual DTC P0134, P0154 HO2S1
EC-227
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC Confirmation ProcedureABS006OB
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If DTC C](/img/42/57021/w960_57021-1567.png)
DTC P0134, P0154 HO2S1
EC-227
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC Confirmation ProcedureABS006OB
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 11V at idle.
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select “HO2S1 (B1) P0134” or “HO2S1 (B2) P0154” of “HO2S1” in “DTC WORK SUPPORT” mode with
CONSULT-II.
3. Touch “START”.
4. Let it idle for at least 3 minutes.
NOTE:
Do not raise engine speed above 3,600 rpm after this step. If
the engine speed limit is exceeded, return to step 4.
5. When the following conditions are met, “TESTING” will be dis-
played on the CONSULT-II screen. Maintain the conditions con-
tinuously until “TESTING” changes to “COMPLETED”. (It will
take approximately 10 to 60 seconds.)
If “TESTING” is not displayed after 5 minutes, retry from
step 2.
6. Make sure that “OK” is displayed after touching “SELF-DIAG
RESULTS”. If “NG” is displayed, refer to EC-232, "
Diagnostic
Procedure" .
PBIB0544E
ENG SPEED 1,200 - 3,100 rpm
Vehicle speed More than 64 km/h (40 MPH)
B/FUEL SCHDL 2.0 - 17.0 msec
Selector lever Suitable position
PBIB0545E
SEC750C
Page 1577 of 4449
![INFINITI FX35 2004 Service Manual EC-236
[VQ35DE]
DTC P0138, P0158 HO2S2
Revision: 2004 November 2004 FX35/FX45
DTC P0138, P0158 HO2S2PFP:226A0
Component DescriptionABS006OH
The heated oxygen sensor 2, after three way catalyst 1, moni INFINITI FX35 2004 Service Manual EC-236
[VQ35DE]
DTC P0138, P0158 HO2S2
Revision: 2004 November 2004 FX35/FX45
DTC P0138, P0158 HO2S2PFP:226A0
Component DescriptionABS006OH
The heated oxygen sensor 2, after three way catalyst 1, moni](/img/42/57021/w960_57021-1576.png)
EC-236
[VQ35DE]
DTC P0138, P0158 HO2S2
Revision: 2004 November 2004 FX35/FX45
DTC P0138, P0158 HO2S2PFP:226A0
Component DescriptionABS006OH
The heated oxygen sensor 2, after three way catalyst 1, monitors the
oxygen level in the exhaust gas on each bank.
Even if switching characteristics of the heated oxygen sensor 1 are
shifted, the air-fuel ratio is controlled to stoichiometric, by the signal
from the heated oxygen sensor 2.
This sensor is made of ceramic zirconia. The zirconia generates volt-
age from approximately 1V in richer conditions to 0V in leaner condi-
tions.
Under normal conditions the heated oxygen sensor 2 is not used for
engine control operation.
CONSULT-II Reference Value in Data Monitor ModeABS006OI
Specification data are reference values.
On Board Diagnosis LogicABS006OJ
The heated oxygen sensor 2 has a much longer switching time
between rich and lean than the heated oxygen sensor 1. The oxygen
storage capacity of the three way catalyst 1 causes the longer
switching time. To judge the malfunctions of heated oxygen sensor
2, ECM monitors whether the voltage is unusually high during the
various driving condition such as fuel-cut.
SEF327R
MONITOR ITEM CONDITION SPECIFICATION
HO2S2 (B1)
HO2S2 (B2)
Warm-up condition
After keeping engine speed
between 3,500 and 4,000 rpm for
1 minute and at idle for 1 minute
under no load.Revving engine from idle to 3,000 rpm
quickly.0 - 0.3V ←→ Approx. 0.6 -
1.0V
HO2S2 MNTR (B1)
HO2S2 MNTR (B2)LEAN ←→ RICH
SEF305UA
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0138
0138
(Bank 1)
Heated oxygen sensor
2 circuit high voltageAn excessively high voltage from the sensor is
sent to ECM.
Harness or connectors
(The sensor circuit is open or shorted)
Heated oxygen sensor 2 P0158
0158
(Bank 2)
Page 1584 of 4449
![INFINITI FX35 2004 Service Manual DTC P0138, P0158 HO2S2
EC-243
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Component InspectionABS006ON
HEATED OXYGEN SENSOR 2
With CONSULT-II
1. Turn ignition switch ON INFINITI FX35 2004 Service Manual DTC P0138, P0158 HO2S2
EC-243
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Component InspectionABS006ON
HEATED OXYGEN SENSOR 2
With CONSULT-II
1. Turn ignition switch ON](/img/42/57021/w960_57021-1583.png)
DTC P0138, P0158 HO2S2
EC-243
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Component InspectionABS006ON
HEATED OXYGEN SENSOR 2
With CONSULT-II
1. Turn ignition switch ON and select “DATA MONITOR” mode with
CONSULT-II.
2. Start engine and warm it up to the normal operating tempera-
ture.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Start engine and keep the engine speed between 3,500 and
4,000 rpm for at least 1 minute under no load.
5. Let engine idle for 1 minute.
6. Select “FUEL INJECTION” in “ACTIVE TEST” mode, and select
“HO2S2 (B1)/(B2)” as the monitor item with CONSULT-II.
7. Check “HO2S2 (B1)/(B2)” at idle speed when adjusting “FUEL INJECTION” to ±25%.
“HO2S2 (B1)/(B2)” should be above 0.63V at least once when the “FUEL INJECTION” is +25%.
“HO2S2 (B1)/(B2)” should be below 0.48V at least once when the “FUEL INJECTION” is −25%.
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7
in) onto a hard surface such as a concrete floor; use a new one.
Before installing new oxygen sensor, clean exhaust system threads (using Oxygen Sensor Thread
Cleaner tool J-43897-18 or J-43897-12) and approved anti-seize lubricant.
Without CONSULT-II
1. Start engine and warm it up to the normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
4. Let engine idle for 1 minute.
5. Set voltmeter probes between ECM terminal 74 [HO2S2 (B1) signal] or 55 [HO2S2 (B2) signal] and
ground.
SEF174Y
SEF662Y
PBIB0796E
Page 1586 of 4449
![INFINITI FX35 2004 Service Manual DTC P0139, P0159 HO2S2
EC-245
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0139, P0159 HO2S2PFP:226A0
Component DescriptionABS006OP
The heated oxygen sensor 2, after INFINITI FX35 2004 Service Manual DTC P0139, P0159 HO2S2
EC-245
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0139, P0159 HO2S2PFP:226A0
Component DescriptionABS006OP
The heated oxygen sensor 2, after](/img/42/57021/w960_57021-1585.png)
DTC P0139, P0159 HO2S2
EC-245
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0139, P0159 HO2S2PFP:226A0
Component DescriptionABS006OP
The heated oxygen sensor 2, after three way catalyst 1, monitors the
oxygen level in the exhaust gas on each bank.
Even if switching characteristics of the heated oxygen sensor 1 are
shifted, the air-fuel ratio is controlled to stoichiometric, by the signal
from the heated oxygen sensor 2.
This sensor is made of ceramic zirconia. The zirconia generates volt-
age from approximately 1V in richer conditions to 0V in leaner condi-
tions.
Under normal conditions the heated oxygen sensor 2 is not used for
engine control operation.
CONSULT-II Reference Value in Data Monitor ModeABS006OQ
Specification data are reference values.
On Board Diagnosis LogicABS006OR
The heated oxygen sensor 2 has a much longer switching time
between rich and lean than the heated oxygen sensor 1. The oxygen
storage capacity before the three way catalyst 1 causes the longer
switching time. To judge the malfunctions of heated oxygen sensor
2, ECM monitors whether the switching response of the sensor's
voltage is faster than specified during the various driving condition
such as fuel-cut.
SEF327R
MONITOR ITEM CONDITION SPECIFICATION
HO2S2 (B1)
HO2S2 (B2)
Warm-up condition
After keeping engine speed
between 3,500 and 4,000 rpm for
1 minute and at idle for 1 minute
under no load.Revving engine from idle to 3,000 rpm
quickly.0 - 0.3V ←→ Approx. 0.6 -
1.0V
HO2S2 MNTR (B1)
HO2S2 MNTR (B2)LEAN ←→ RICH
SEF302U
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0139
0139
(Bank 1)
Heated oxygen sensor
2 circuit slow responseIt takes more time for the sensor to respond
between rich and lean than the specified time.
Harness or connectors
(The sensor circuit is open or shorted)
Heated oxygen sensor 2
Fuel pressure
Fuel injector
Intake air leaks P0159
0159
(Bank 2)
Page 1595 of 4449
![INFINITI FX35 2004 Service Manual EC-254
[VQ35DE]
DTC P0139, P0159 HO2S2
Revision: 2004 November 2004 FX35/FX45
6. Select “FUEL INJECTION” in “ACTIVE TEST” mode, and select
“HO2S2 (B1)/(B2)” as the monitor item with CONSUL INFINITI FX35 2004 Service Manual EC-254
[VQ35DE]
DTC P0139, P0159 HO2S2
Revision: 2004 November 2004 FX35/FX45
6. Select “FUEL INJECTION” in “ACTIVE TEST” mode, and select
“HO2S2 (B1)/(B2)” as the monitor item with CONSUL](/img/42/57021/w960_57021-1594.png)
EC-254
[VQ35DE]
DTC P0139, P0159 HO2S2
Revision: 2004 November 2004 FX35/FX45
6. Select “FUEL INJECTION” in “ACTIVE TEST” mode, and select
“HO2S2 (B1)/(B2)” as the monitor item with CONSULT-II.
7. Check “HO2S2 (B1)/(B2)” at idle speed when adjusting “FUEL INJECTION” to ±25%.
“HO2S2 (B1)/(B2)” should be above 0.63V at least once when the “FUEL INJECTION” is +25%.
“HO2S2 (B1)/(B2)” should be below 0.48V at least once when the “FUEL INJECTION” is −25%.
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7
in) onto a hard surface such as a concrete floor; use a new one.
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread
Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.
Without CONSULT-II
1. Start engine and warm it up to the normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
4. Let engine idle for 1 minute.
5. Set voltmeter probes between ECM terminal 74 [HO2S2 (B1) signal] or 55 [HO2S2 (B2) signal] and
ground.
6. Check the voltage when revving up to 4,000 rpm under no load
at least 10 times.
(Depress and release accelerator pedal as soon as possible.)
The voltage should be above 0.63V at least once during this
procedure.
If the voltage is above 0.63V at step 6, step 7 is not neces-
sary.
7. Keep vehicle at idling for 10 minutes, then check voltage. Or
check the voltage when coasting from 80 km/h (50 MPH) in D
position with “OD” OFF.
The voltage should be below 0.48V at least once during this
procedure.
8. If NG, replace heated oxygen sensor 2.
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7
in) onto a hard surface such as a concrete floor; use a new one.
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread
Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.
SEF662Y
PBIB0796E
PBIB1607E
Page 1597 of 4449
![INFINITI FX35 2004 Service Manual EC-256
[VQ35DE]
DTC P0171, P0174 FUEL INJECTION SYSTEM FUNCTION
Revision: 2004 November 2004 FX35/FX45
DTC P0171, P0174 FUEL INJECTION SYSTEM FUNCTIONPFP:16600
On Board Diagnosis LogicABS006OY
With th INFINITI FX35 2004 Service Manual EC-256
[VQ35DE]
DTC P0171, P0174 FUEL INJECTION SYSTEM FUNCTION
Revision: 2004 November 2004 FX35/FX45
DTC P0171, P0174 FUEL INJECTION SYSTEM FUNCTIONPFP:16600
On Board Diagnosis LogicABS006OY
With th](/img/42/57021/w960_57021-1596.png)
EC-256
[VQ35DE]
DTC P0171, P0174 FUEL INJECTION SYSTEM FUNCTION
Revision: 2004 November 2004 FX35/FX45
DTC P0171, P0174 FUEL INJECTION SYSTEM FUNCTIONPFP:16600
On Board Diagnosis LogicABS006OY
With the Air-Fuel Mixture Ratio Self-Learning Control, the actual mixture ratio can be brought closely to the
theoretical mixture ratio based on the mixture ratio feedback signal from the heated oxygen sensors 1. The
ECM calculates the necessary compensation to correct the offset between the actual and the theoretical
ratios.
In case the amount of the compensation value is extremely large (the actual mixture ratio is too lean.), the
ECM judges the condition as the fuel injection system malfunction and lights up the MIL (2 trip detection logic).
DTC Confirmation ProcedureABS006OZ
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON and select “SELF-LEARNING CONT” in “WORK SUPPORT” mode with CON-
SULT-II.
4. Clear the self-learning control coefficient by touching “CLEAR”.
5. Select “DATA MONITOR” mode with CONSULT-II.
6. Start engine again and let it idle for at least 10 minutes.
The 1st trip DTC P0171 or P0174 should be detected at this
stage, if a malfunction exists. If so, go to Diagnostic Procedure,
EC-260
.
7. If it is difficult to start engine at step 6, the fuel injection system
has a malfunction, too.
8. Crank engine while depressing accelerator pedal. If engine
starts, go to EC-260, "
Diagnostic Procedure" . If engine does not
start, check exhaust and intake air leak visually.
Sensor Input signal to ECM ECM function Actuator
Heated oxygen sensor 1Density of oxygen in exhaust gas
(Mixture ratio feedback signal)Fuel injection
controlFuel injector
DTC No.Trouble diagnosis
nameDTC detecting condition Possible cause
P0171
0171
(Bank 1)
Fuel injection system
too lean
Fuel injection system does not operate properly.
The amount of mixture ratio compensation is too
large. (The mixture ratio is too lean.)
Intake air leaks
Heated oxygen sensor 1
Fuel Injector
Exhaust gas leaks
Incorrect fuel pressure
Lack of fuel
Mass air flow sensor
Incorrect PCV hose connection P0174
0174
(Bank 2)
SEF968Y