lights INFINITI FX35 2004 Repair Manual
[x] Cancel search | Manufacturer: INFINITI, Model Year: 2004, Model line: FX35, Model: INFINITI FX35 2004Pages: 4449, PDF Size: 99.66 MB
Page 3602 of 4449

DAYTIME LIGHT SYSTEM
LT-47
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
2. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM connector.
3. Check voltage between BCM harness connector and ground.
OK or NG
OK >> GO TO 3.
NG >> Check harness for open or short between BCM and
fuse.
3. CHECK GROUND CIRCUIT
Check continuity between BCM harness connector and ground.
OK or NG
OK >> INSPECTION END
NG >> Check ground circuit harness.
INSPECTION PARKING BRAKE SWITCH CIRCUIT
1. CHECK BRAKE INDICATOR
1. Turn ignition switch ON
2. When parking brake is made ON/OFF, it checks whether the brake indicator lamp of combination meter
lights up/puts out the light.
OK or NG
OK >> INSPECTION END
NG >> GO TO 2.
Terminals Ignition switch position
(+)
(-) OFF ON
Connector Terminal (Wire color)
M3 38 (W/L)
Ground0V Battery voltage
M442 (L/R) Battery voltage Battery voltage
55 (G) Battery voltage Battery voltage
SKIA7095E
Terminals
Continuity
Connector Terminal (Wire color)
M449 (B)
Ground Yes
52 (B)
PKIA5191E
Page 3623 of 4449

LT-68
AUTO LIGHT SYSTEM
Revision: 2004 November 2004 FX35/FX45
3. Touch “START”.
4. Touch the required monitoring item on “SELECTION FROM MENU”. In “ALL SIGNALS”, all items are
monitored. In “MAIN SIGNALS”, predetermined items are monitored.
5. Touch “RECORD” while monitoring to record the status of the item being monitored. To stop recording,
touch “STOP”.
All Signals, Main Signals, Selection From Menu
NOTE:
Perform monitoring of IPDM E/R data with the ignition switch ON. When the ignition switch is at ACC, the dis-
play may not be correct.
ACTIVE TEST
Operation Procedure
1. Touch “ACTIVE TEST” on “SELECT DIAG MODE” screen.
2. Touch item to be tested, and check operation.
3. Touch “START”.
4. Touch “STOP” while testing to stop the operation.
Trouble Diagnosis Chart by SymptomAKS007F3
ALL SIGNALS All items will be monitored.
MAIN SIGNALS Monitor the predetermined item.
SELECTION FROM MENU Select any item for monitoring.
Item nameCONSULT-II
screen displayDisplay
or unitMonitor item selection
Description
ALL
SIGNALSMAIN
SIGNALSSELECTION
FROM MENU
Position lights request TAIL & CLR REQ ON/OFF×× ×Signal status input from BCM
Headlamp low beam request HL LO REQ ON/OFF×× ×Signal status input from BCM
Headlamp high beam request HL HI REQ ON/OFF×× ×Signal status input from BCM
Font fog lights request FR FOG REQ ON/OFF×× ×Signal status input from BCM
Te s t i t e mCONSULT-II
screen displayDescription
Headlamp relay (HI, LO) output
LAMPSAllows headlamp relay (HI, LO) to operate by switching operation (OFF, HI ON,
LO ON) at your option (Head lamp high beam repeats ON–OFF every 1 second).
Front fog lamp relay output Allows fog lamp relay to operate by switching operation ON-OFF at your option
Tail lamp relay output TAIL LAMP Allows tail lamp relay to operate by switching operation ON-OFF at your option
Trouble phenomenon Malfunction system and reference
Parking lamps and headlamps will not illuminate when out-
side of the vehicle becomes dark. (Lighting switch 1st posi-
tion and 2nd position operate normally.)
Parking lamps and headlamp will not go out when outside
of the vehicle becomes light. (Lighting switch 1st position
and 2nd position operate normally.)
Headlamps go out when outside of the vehicle becomes
light, but parking lamps stay on.
Refer to LT- 6 4 , "WORK SUPPORT" .
Refer to LT- 6 9 , "Lighting Switch Inspection" .
Refer to LT- 6 9 , "Optical Sensor System Inspection" .
If above systems are normal, replace BCM.
Parking lamps illuminate when outside of the vehicle
becomes dark, but headlamps stay off. (Lighting switch 1st
position and 2nd position operate normally.)
Refer to LT- 6 4 , "WORK SUPPORT" .
Refer to LT- 6 9 , "Optical Sensor System Inspection" .
If above systems are normal, replace BCM.
Auto light adjustment system will not operate. (Lighting switch
AUTO, 1st position and 2nd position operate normally.)
Refer to LT- 6 9 , "Optical Sensor System Inspection" .
If above system is normal, replace BCM.
Page 4270 of 4449

TROUBLE DIAGNOSIS
SRS-29
C
D
E
F
G
I
J
K
L
MA
B
SRS
Revision: 2004 November 2004 FX35/FX45
Trouble Diagnosis without CONSULT-IIAHS000HT
DIAGNOSTIC PROCEDURE 6
Inspecting SRS Malfunctioning Parts by Using “AIR BAG” Warning Lamp — Diagnosis Mode
NOTE:
SRS will not enter Diagnosis mode if no malfunction is detected in User mode.
1. Turn ignition switch ON.
2. After “AIR BAG” warning lamp lights for 7 seconds, turn ignition switch OFF within 1 second.
3. Wait more than 3 seconds.
4. Repeat the steps 1 to 3 twice. (Perform three times in all.)
5. Turn ignition switch ON.
SRS is now in Diagnosis mode.
“AIR BAG” warning lamp operates in Diagnosis mode as follows:
CURTAIN MODULE RH
[OPEN]RH side curtain air bag module circuit is open. 1. Visually check the wiring harness
connection.
2. Replace the harness if it has visible
damage.
3. If the harness check result is OK,
replace the diagnosis sensor unit
and RH side curtain air bag module.
(Before disposal, it must be
deployed.) CURTAIN MODULE RH
[VB-SHORT]
RH side curtain air bag module circuit is shorted to a power sup-
ply circuit.
CURTAIN MODULE RH
[GND-SHORT]
RH side curtain air bag module circuit is shorted to ground.
CURTAIN MODULE RH
[SHORT]
RH side curtain air bag module circuit is shorted between lines.
CONTROL UNIT
Diagnosis sensor unit is malfunctioning. 1. Visually check the wiring harness
connection.
2. Replace the diagnosis sensor unit. Diagnostic item ExplanationRepair order
“Recheck SRS at each replacement”