air INFINITI FX35 2005 Service Manual
[x] Cancel search | Manufacturer: INFINITI, Model Year: 2005, Model line: FX35, Model: INFINITI FX35 2005Pages: 4731, PDF Size: 60.13 MB
Page 990 of 4731

BACK DOOR AUTO CLOSURE SYSTEM BL-175
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
Work FlowAIS004OH
1. Check the symptom and customer's requests.
2. Understand the outline of system. Refer to BL-170, "
System Description" .
3. Perform the preliminary check, Refer to BL-175, "
Preliminary Check"
4. According to the trouble diagnosis chart, repair or replace the cause of the malfunction. Refer to BL-175,
"Trouble Diagnosis Chart by Symptom" .
5. Does back door auto closure system operate normally? If Yes, GO TO 6, If No, GO TO 4.
6. INSPECTION END
Preliminary CheckAIS004OI
Remove the fuse No.18 for the back door closure with the back door closure inactive.
Check that the back door can be open / close normally.
CAUTION:
It is judged it is abnormal, discontinues closure operation, and drive lever returns to a neutral position
if not becoming full-latch within about three seconds after half-latch.
When this operation is done continuously three times, both back door closure and back door opener
switch are not operated because the function of back door closure is stopped.
Thing to reset power supply by pulling out and opening fuse in that case.
Trouble Diagnosis Chart by SymptomAIS004OJ
Symptom Diagnostic procedure and repair order Refer to page
Back door closure does not operate. 1.Back door closure motor power supply and ground
circuit check BL-176
2. Half-latch switch check
BL-176
3. Close switch checkBL-178
4. Open switch check.BL-179
5. Closure motor check.BL-185
6. Replace back door closure control unit.BL-185
Back door does not open (with Intelligent Key system). 1. Intelligent Key system check.
BL-1182. Back door opener switch check.BL-180
Back door does not open 1. Back door opener switch check.
BL-1822. Unlock sensor check.BL-184
3. Replace back door closure control unit.BL-185
Back door does not enter fully closed states through
back door closure operates. 1.Back door fitting adjustment.
BL-164
2. Replace back door lock assembly.BL-168
Page 991 of 4731

BL-176
BACK DOOR AUTO CLOSURE SYSTEM
Revision: 2005 July 2005 FX
Back Door Closure Control Unit Power Supply and Ground Circuit CheckAIS004OK
1. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Check voltage between back door closure control unit connector D106 terminal 1 and ground.
OK or NG
OK >> GO TO 2.
NG >> Check the following.
15A fuse [No.18, located in fuse block (J/B)]
Harness for open or short between back door closure
control unit and fuse.
2. CHECK GROUND CIRCUIT
1. Disconnect back door closure control unit connector.
2. Check continuity between back door closure control unit con- nector D106 terminal 4 and ground.
OK or NG
OK >> Power supply and ground circuit are OK.
NG >> Repair or replace harness.
Half-Latch Switch CheckAIS004OL
1. CHECK HALF-LATCH SWITCH SIGNAL
1. Turn ignition switch OFF.
2. Check the signal between back door closure control unit connector and ground with oscilloscope.
OK or NG
OK >> Half-latch switch is OK.
NG >> GO TO 2. 1 (R) – Ground : Battery voltage
PIIA6166E
4 (B) – Ground : Continuity should exist.
PIIA6167E
Con-
nector Terminals (Wire color)
Back door
condition Signal
(Reference value)
(+) (-)
D106 7 (OR) Ground Fully open
→
fully closed
PIIA6168E
SIIA1479J
Page 992 of 4731

BACK DOOR AUTO CLOSURE SYSTEM BL-177
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
2. CHECK HARNESS CONTINUITY
1. Disconnect back door closure control unit and back door closure motor connector.
2. Check continuity between back door closure control unit con- nector D106 terminal 7 and back door closure motor connector
D109 terminal 6.
3. Check continuity between back door closure control unit con- nector D106 terminal 7 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CHECK GROUND CIRCUIT
Check continuity between back door closure motor connector D109
terminal 8 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
4. CHECK BACK DOOR CLOSURE CONTROL UNIT OUTPUT SIGNAL
1. Connect back door closure control unit connector.
2. Check voltage between back door closure control unit connector D106 terminal 7 and ground.
OK or NG
OK >> Replace back door lock assembly.
NG >> Replace back door closure control unit. 7 (OR) – 6 (OR) : Continuity should exist.
7 (OR) – Ground : Continuity should not exist.
PIIA6169E
8 (B) – Ground : Continuity should exist.
PIIA6170E
Back door is closed
7 (OR) – Ground : Battery voltage
PIIA6172E
Page 993 of 4731

BL-178
BACK DOOR AUTO CLOSURE SYSTEM
Revision: 2005 July 2005 FX
Close Switch CheckAIS004OM
1. CHECK CLOSE SWITCH SIGNAL
1. Turn ignition switch OFF.
2. Check the signal between back door closure control unit connector and ground with oscilloscope.
OK or NG
OK >> Close switch is OK.
NG >> GO TO 2.
2. CHECK HARNESS CONTINUITY
1. Disconnect back door closure control unit and back door closure motor connector.
2. Check continuity between back door closure control unit con- nector D106 terminal 8 and back door closure motor connector
D109 terminal 5.
3. Check continuity between back door closure control unit con- nector D106 terminal 8 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CHECK GROUND CIRCUIT
Check continuity between back door closure motor connector D109
terminal 8 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
Con-
nector Terminals (Wire color)
Back door
condition Signal
(Reference value)
(+) (-)
D106 8 (L) Ground Fully open
→
fully closed
PIIA6171E
SIIA1478J
8 (L) – 5 (L) : Continuity should exist.
8 (L) – Ground : Continuity should not exist.
PIIA6174E
8 (B) – Ground : Continuity should exist.
PIIA6170E
Page 994 of 4731

BACK DOOR AUTO CLOSURE SYSTEM BL-179
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
4. CHECK BACK DOOR CLOSURE CONTROL UNIT OUTPUT SIGNAL
1. Connect back door closure control unit connector.
2. Check voltage between back door closure control unit connector D106 terminal 8 and ground.
OK or NG
OK >> Replace back door lock assembly.
NG >> Replace back door closure control unit.
Open Switch CheckAIS004ON
1. CHECK OPEN SWITCH SIGNAL
1. Turn ignition switch OFF.
2. Check the signal between back door closure control unit connector and ground with oscilloscope.
OK or NG
OK >> Open switch is OK.
NG >> GO TO 2.
2. CHECK HARNESS CONTINUITY
1. Disconnect back door closure control unit and back door closure motor connector.
2. Check continuity between back door closure control unit con- nector D106 terminal 9 and back door closure motor connector
D109 terminal 4.
3. Check continuity between back door closure control unit con- nector D106 terminal 9 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness. Back door is closed
8 (L) – Ground : Battery voltage
PIIA6173E
Con-
nector Terminals (Wire color)
Back door
condition Signal
(Reference value)
(+) (-)
D106 9 (P) Ground Fully open
→
fully closed
PIIA6175E
SIIA1481J
9 (P) – 4 (P) : Continuity should exist.
9 (P) – Ground : Continuity should not exist.
PIIA6176E
Page 995 of 4731

BL-180
BACK DOOR AUTO CLOSURE SYSTEM
Revision: 2005 July 2005 FX
3. CHECK GROUND CIRCUIT
Check continuity between back door closure motor connector D109
terminal 8 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
4. CHECK BACK DOOR CLOSURE CONTROL UNIT OUTPUT SIGNAL
1. Connect back door closure control unit connector.
2. Check voltage between back door closure control unit connector D106 terminal 9 and ground.
OK or NG
OK >> Replace back door lock assembly.
NG >> Replace back door closure control unit.
Back Door Opener Switch Check (With Intelligent Key)AIS004U8
1. CHECK BACK DOOR OPENER SWITCH SIGNAL
1. Turn ignition switch OFF.
2. Check voltage between back door closure control unit connector and ground.
OK or NG
OK >> Back door opener switch is OK.
NG >> GO TO 2. 8 (B) – Ground : Continuity should exist.
PIIA6170E
Back door is closed
9 (P) – Ground : Battery voltage
PIIA6177E
Connector Terminals (Wire color)
Condition Voltage (V)
(Approx.)
(+) (-)
D106 6 (LG) Ground Back door opener switch
: ON 0
Back door opener switch
: OFF 5
PIIA6178E
Page 996 of 4731

BACK DOOR AUTO CLOSURE SYSTEM BL-181
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
2. CHECK HARNESS 1
1. Disconnect Intelligent Key unit and back door closure control unit connector.
2. Check continuity between Intelligent Key unit connector M34 ter- minal 23 and back door closure control unit connector D106 ter-
minal 6.
3. Check continuity between Intelligent Key unit connector M34 ter- minal 23 and ground.
OK or NG
OK >> GO TO 3.
NG >> Replace or repair malfunction harness.
3. CHECK HARNESS 2
1. Disconnect Intelligent Key unit and back door opener switch connector.
2. Check continuity between Intelligent Key unit connector M34 ter- minal 24 and back door opener switch connector D112 terminal
1.
3. Check continuity between Intelligent Key unit connector M34 ter- minal 24 and ground.
OK or NG
OK >> GO TO 4.
NG >> Replace or repair malfunction harness.
4. CHECK BACK DOOR OPENER SWITCH GROUND CIRCUIT
Check continuity between back door opener switch connector D112
terminal 2 and ground.
OK or NG
OK >> GO TO 5.
NG >> Repair or replace harness.
5. CHECK BACK DOOR OPENER SWITCH
Check continuity between back door opener switch terminals 1 and
2.
OK or NG
OK >> GO TO 6.
NG >> Replace back door opener switch. 23 (L/Y) – 6 (LG) : Continuity should exist.
23 (L/Y) - Ground : Continuity should not exist.
PIIB0216E
24 (P) – 1 (Y) : Continuity should exist.
24 (P) - Ground : Continuity should not exist.
PIIB1384E
2 (B) – Ground : Continuity should exist.
PIIA6180E
Terminals Condition Continuity
12 Back door opener switch: ON Yes
Back door opener switch: OFF No
PIIA6181E
Page 997 of 4731

BL-182
BACK DOOR AUTO CLOSURE SYSTEM
Revision: 2005 July 2005 FX
6. CHECK BACK DOOR CLOSURE CONTROL UNIT OUTPUT SIGNAL
1. Connect back door closure control unit connector.
2. Check voltage between back door closure control unit connector D106 terminal 6 and ground.
OK or NG
OK >> Replace Intelligent Key unit.
NG >> Replace back door closure control unit.
Back Door Opener Switch Check (Without Intelligent Key)AIS004U9
1. CHECK BACK DOOR OPENER SWITCH SIGNAL
1. Turn ignition switch OFF.
2. Check voltage between back door closure control unit connector and ground.
OK or NG
OK >> Back door opener switch is OK.
NG >> GO TO 2.
2. CHECK HARNESS CONTINUITY
1. Disconnect back door closure control unit and back door opener switch connector.
2. Check continuity between back door closure control unit con- nector D106 terminal 6 and back door opener switch connector
D112 terminal 1.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness between back door closure control unit and back door opener switch.
6 (LG) – Ground : Approx. 5V
PIIA6178E
Connector
Terminals (Wire color)
Condition Voltage (V)
(Approx.)
(+) (-)
D106 6 (Y) Ground Back door opener switch
: ON 0
Back door opener switch
: OFF 5
PIIA6178E
6 (Y) – 1 (Y) : Continuity should exist.
PIIA6179E
Page 998 of 4731

BACK DOOR AUTO CLOSURE SYSTEM BL-183
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
3. CHECK GROUND CIRCUIT
Check continuity between back door opener switch connector D112
terminal 2 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
4. CHECK BACK DOOR OPENER SWITCH
Check continuity between back door opener switch terminals 1 and
2.
OK or NG
OK >> GO TO 5.
NG >> Replace back door opener switch.
5. CHECK BACK DOOR CLOSURE CONTROL UNIT OUTPUT SIGNAL
1. Connect back door closure control unit connector.
2. Check voltage between back door closure control unit connector D106 terminal 6 and ground.
OK or NG
OK >> Check condition of harness and connector.
NG >> Replace back door closure control unit. 2 (B) – Ground : Continuity should exist.
PIIA6180E
Terminals Condition Continuity
12 Back door opener switch: ON Yes
Back door opener switch: OFF No
PIIA6181E
6 (Y) – Ground : Approx. 5V
PIIA6178E
Page 999 of 4731

BL-184
BACK DOOR AUTO CLOSURE SYSTEM
Revision: 2005 July 2005 FX
Unlock Sensor Check (Without Intelligent Key)AIS004UA
1. CHECK UNLOCK SENSOR SIGNAL
1. Turn ignition switch OFF.
2. Check voltage between back door closure control unit connector and ground.
OK or NG
OK >> Unlock sensor is OK.
NG >> GO TO 2.
2. CHECK HARNESS CONTINUITY
1. Disconnect back door closure control unit and front door lock assembly (passenger side) connector.
2. Check continuity between back door closure control unit con- nector D106 terminal 5 and front door lock assembly (passenger
side) connector D40 terminal 5.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness between back door closure
control unit and front door lock assembly (passenger
side).
3. CHECK GROUND CIRCUIT
Check continuity between front door lock assembly (passenger side)
connector D40 terminal 4 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
Connector Terminals (Wire color)
Condition Voltage (V)
(Approx.)
(+) (-)
D106 5 (W) Ground Passenger side door lock is
locked 5
Passenger side door lock is
unlocked 0
PIIA6182E
5 (W) – 5 (W) : Continuity should exist.
PIIA6183E
4 (B) – Ground : Continuity should exist.
PIIA6184E