service INFINITI FX35 2006 Service Manual
[x] Cancel search | Manufacturer: INFINITI, Model Year: 2006, Model line: FX35, Model: INFINITI FX35 2006Pages: 4462, PDF Size: 57.74 MB
Page 2445 of 4462
![INFINITI FX35 2006 Service Manual DTC P0442 EVAP CONTROL SYSTEM EC-1061
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
13. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
W INFINITI FX35 2006 Service Manual DTC P0442 EVAP CONTROL SYSTEM EC-1061
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
13. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
W](/img/42/57019/w960_57019-2444.png)
DTC P0442 EVAP CONTROL SYSTEM EC-1061
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
13. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Stop engine.
3. Disconnect vacuum hose to EVAP canister purge volume control solenoid valve at EVAP service port.
4. Start engine and let it idle for at least 80 seconds.
5. Check vacuum hose for vacuum when revving engine up to 2,000 rpm.
OK or NG
OK >> GO TO 16.
NG >> GO TO 14.
14. CHECK VACUUM HOSE
Check vacuum hoses for clogging or disconnection. Refer to EC-768, "
Vacuum Hose Drawing" .
OK or NG
OK >> GO TO 15.
NG >> Repair or reconnect the hose.
15. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Refer to EC-1076, "
Component Inspection" .
OK or NG
OK >> GO TO 16.
NG >> Replace EVAP canister purge volume control solenoid valve.
16. CHECK FUEL TANK TEMPERATURE SENSOR
Refer to EC-1002, "
Component Inspection" .
OK or NG
OK >> GO TO 17.
NG >> Replace fuel level sensor unit.
17. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to EC-1099, "
Component Inspection" .
OK or NG
OK >> GO TO 18.
NG >> Replace EVAP control system pressure sensor.
18. CHECK EVAP PURGE LINE
Check EVAP purge line (pipe, rubber tube, fuel tank and EVAP canister) for cracks or improper connection.
Refer to EC-700, "
EVAPORATIVE EMISSION LINE DRAWING" .
OK or NG
OK >> GO TO 19.
NG >> Repair or reconnect the hose.
19. CLEAN EVAP PURGE LINE
Clean EVAP purge line (pipe and rubber tube) using air blower.
>> GO TO 20.
Vacuum should exist.
Page 2448 of 4462
![INFINITI FX35 2006 Service Manual EC-1064
[VK45DE]
DTC P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Revision: 2006 December 2006 FX35/FX45
On Board Diagnosis LogicNBS004DG
DTC Confirmation ProcedureNBS004DH
NOTE:
If DTC Co INFINITI FX35 2006 Service Manual EC-1064
[VK45DE]
DTC P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Revision: 2006 December 2006 FX35/FX45
On Board Diagnosis LogicNBS004DG
DTC Confirmation ProcedureNBS004DH
NOTE:
If DTC Co](/img/42/57019/w960_57019-2447.png)
EC-1064
[VK45DE]
DTC P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Revision: 2006 December 2006 FX35/FX45
On Board Diagnosis LogicNBS004DG
DTC Confirmation ProcedureNBS004DH
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Always perform test at a temperature of 5 °C (41 °F) or more.
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Select “PURG VOL CN/V P1444” of “EVAPORATIVE SYSTEM” in “DTC WORK SUPPORT” mode with CONSULT-II.
5. Touch “START”.
6. Start engine and let it idle until “TESTING” on CONSULT-II changes to “COMPLETED”. (It will take approximately 10 seconds.)
If “TESTING” is not displayed after 5 minutes, retry from step 2.
7. Make sure that “OK” is displayed after touching “SELF-DIAG RESULTS”. If “NG” is displayed, refer to EC-
1067, "Diagnostic Procedure" .
WITH GST
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and let it idle for at least 20 seconds.
4. Select “Service $07” with GST.
5. If 1st trip DTC is detected, go to EC-1067, "
Diagnostic Procedure" .
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0443
0443 EVAP canister purge
volume control solenoid
valve The canister purge flow is detected during the
specified driving conditions, even when EVAP
canister purge volume control solenoid valve is
completely closed.
EVAP control system pressure sensor
EVAP canister purge volume control
solenoid valve
(The valve is stuck open.)
EVAP canister vent control valve
EVAP canister
Hoses
(Hoses are connected incorrectly or
clogged.)
PBIB0839E
Page 2451 of 4462
![INFINITI FX35 2006 Service Manual DTC P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-1067
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
Diagnostic ProcedureNBS004DJ
1. CHECK EVAP CA INFINITI FX35 2006 Service Manual DTC P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-1067
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
Diagnostic ProcedureNBS004DJ
1. CHECK EVAP CA](/img/42/57019/w960_57019-2450.png)
DTC P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-1067
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
Diagnostic ProcedureNBS004DJ
1. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIR-
CUIT 1. Turn ignition switch OFF.
2. Disconnect EVAP canister purge volume control solenoid valve (1) harness connector.
–EVAP service port (2)
3. Turn ignition switch ON.
4. Check voltage between EVAP canister purge volume control solenoid valve terminal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
2. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E211, M41
Harness connectors M82, F102
IPDM E/R harness connector E7
Harness for open or short between EVAP canister purge volume control solenoid valve and IPDM E/R
Harness for open or short between EVAP canister purge volume control solenoid valve and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
3. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIR-
CUIT FOR OPEN AND SHORT 1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 45 and EVAP canister purge volume control solenoid valve terminal 2. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
PBIB3238E
Voltage: Battery voltage
PBIB0148E
Continuity should exist.
Page 2459 of 4462
![INFINITI FX35 2006 Service Manual DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-1075
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
Diagnostic ProcedureNBS00483
1. CHEC INFINITI FX35 2006 Service Manual DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-1075
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
Diagnostic ProcedureNBS00483
1. CHEC](/img/42/57019/w960_57019-2458.png)
DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-1075
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
Diagnostic ProcedureNBS00483
1. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIR-
CUIT 1. Turn ignition switch OFF.
2. Disconnect EVAP canister purge volume control solenoid valve (1) harness connector.
–EVAP service port (2)
3. Turn ignition switch ON.
4. Check voltage between EVAP canister purge volume control solenoid valve terminal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
2. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E211, M41
Harness connectors M82, F102
Harness for open or short between EVAP canister purge volume control solenoid valve and IPDM E/R
Harness for open or short between EVAP canister purge volume control solenoid valve and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
3. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIR-
CUIT FOR OPEN AND SHORT 1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 45 and EVAP canister purge volume control solenoid valve terminal 2. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK (With CONSULT-II)>>GO TO 4.
OK (Without CONSULT-II)>>GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
PBIB3238E
Voltage: Battery voltage
PBIB0148E
Continuity should exist.
Page 2479 of 4462
![INFINITI FX35 2006 Service Manual DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1095
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
DTC Confirmation ProcedureNBS0048M
NOTE:
If DTC Confirmati INFINITI FX35 2006 Service Manual DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1095
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
DTC Confirmation ProcedureNBS0048M
NOTE:
If DTC Confirmati](/img/42/57019/w960_57019-2478.png)
DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1095
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
DTC Confirmation ProcedureNBS0048M
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Always perform test at a temperature of 5 °C (41 °F) or more.
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Select “DATA MONITOR” mode with CONSULT-II.
5. Make sure that “FUEL T/TMP SE” is more than 0 °C (32 °F).
6. Start engine and wait at least 20 seconds. If 1st trip DTC is detected, go to EC-1097, "
Diagnostic Proce-
dure" .
WITH GST
1. Start engine and warm it up to normal operating temperature.
2. Check that voltage between ECM terminal 107 (Fuel tank tem- perature sensor signal) and ground is less than 4.2V.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Start engine and wait at least 20 seconds.
5. Select “Service $07” with GST. If 1st trip DTC is detected, go to EC-1097, "
Diagnostic Proce-
dure" .
SEF194Y
PBIB1110E
Page 2485 of 4462
![INFINITI FX35 2006 Service Manual DTC P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1101
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
DTC Confirmation ProcedureNBS0048T
NOTE:
If DTC Confirmati INFINITI FX35 2006 Service Manual DTC P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1101
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
DTC Confirmation ProcedureNBS0048T
NOTE:
If DTC Confirmati](/img/42/57019/w960_57019-2484.png)
DTC P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1101
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
DTC Confirmation ProcedureNBS0048T
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Always perform test at a temperature of 5 °C (41 °F) or more.
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Select “DATA MONITOR” mode with CONSULT-II.
5. Make sure that “FUEL T/TMP SE” is more than 0 °C (32 °F).
6. Start engine and wait at least 20 seconds.
7. If 1st trip DTC is detected, go to EC-1103, "
Diagnostic Proce-
dure" .
WITH GST
1. Start engine and warm it up to normal operating temperature.
2. Check that voltage between ECM terminal 107 (Fuel tank tem- perature sensor signal) and ground is less than 4.2V.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Start engine and wait at least 20 seconds.
5. Select “Service $07” with GST. If 1st trip DTC is detected, go to EC-1103, "
Diagnostic Proce-
dure" .
SEF194Y
PBIB1110E
Page 2494 of 4462
![INFINITI FX35 2006 Service Manual EC-1110
[VK45DE]
DTC P0455 EVAP CONTROL SYSTEM
Revision: 2006 December 2006 FX35/FX45
7. Make sure that “OK” is displayed. If “NG” is displayed, select “SELF-DIAG RESULTS” mode and
make su INFINITI FX35 2006 Service Manual EC-1110
[VK45DE]
DTC P0455 EVAP CONTROL SYSTEM
Revision: 2006 December 2006 FX35/FX45
7. Make sure that “OK” is displayed. If “NG” is displayed, select “SELF-DIAG RESULTS” mode and
make su](/img/42/57019/w960_57019-2493.png)
EC-1110
[VK45DE]
DTC P0455 EVAP CONTROL SYSTEM
Revision: 2006 December 2006 FX35/FX45
7. Make sure that “OK” is displayed. If “NG” is displayed, select “SELF-DIAG RESULTS” mode and
make sure that “EVAP GROSS LEAK [P0455]” is displayed. If it
is displayed, refer to E C - 111 0 , "
Diagnostic Procedure" .
If P0442 is displayed, perform Diagnostic Procedure for DTC
P0442 EC-1057, "
Diagnostic Procedure" .
WITH GST
NOTE:
Be sure to read the explanation of EC-724, "
Driving Pattern" before driving vehicle.
1. Start engine.
2. Drive vehicle according to EC-724, "
Driving Pattern" .
3. Stop vehicle.
4. Turn ignition switch OFF, wait at least 10 seconds and then turn ON.
5. Select “Service $07” with GST.
If P0455 is displayed on the screen, go to E C - 111 0 , "Diagnostic Procedure" .
If P0442 is displayed on the screen, go to EC-1057, "Diagnostic Procedure" .
If P0441 is displayed on the screen, go to EC-1051, "Diagnostic Procedure" .
Diagnostic ProcedureNBS0048Z
1. CHECK FUEL FILLER CAP DESIGN
1. Turn ignition switch OFF.
2. Check for genuine NISSAN fuel filler cap design.
OK or NG
OK >> GO TO 2.
NG >> Replace with genuine NISSAN fuel filler cap.
2. CHECK FUEL FILLER CAP INSTALLATION
Check that the cap is tightened properly by rotating the cap clockwise.
OK or NG
OK >> GO TO 3.
NG >> 1. Open fuel filler cap, then clean cap and fuel filler neck threads using air blower.
2. Retighten until ratcheting sound is heard.
3. CHECK FUEL FILLER CAP FUNCTION
Check for air releasing sound while opening the fuel filler cap.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
SEC763C
SEF915U
Page 2496 of 4462
![INFINITI FX35 2006 Service Manual EC-1112
[VK45DE]
DTC P0455 EVAP CONTROL SYSTEM
Revision: 2006 December 2006 FX35/FX45
8. INSTALL THE PRESSURE PUMP
To locate the EVAP leak, install EVAP service port adapter and pres-
sure pump to E INFINITI FX35 2006 Service Manual EC-1112
[VK45DE]
DTC P0455 EVAP CONTROL SYSTEM
Revision: 2006 December 2006 FX35/FX45
8. INSTALL THE PRESSURE PUMP
To locate the EVAP leak, install EVAP service port adapter and pres-
sure pump to E](/img/42/57019/w960_57019-2495.png)
EC-1112
[VK45DE]
DTC P0455 EVAP CONTROL SYSTEM
Revision: 2006 December 2006 FX35/FX45
8. INSTALL THE PRESSURE PUMP
To locate the EVAP leak, install EVAP service port adapter and pres-
sure pump to EVAP service port (2) securely.
EVAP canister purge volume control solenoid valve (1)
NOTE:
Improper installation of the EVAP service port adapter to the
EVAP service port may cause leaking.
With CONSULT-II>>GO TO 9.
Without CONSULT-II>>GO TO 10.
9. CHECK FOR EVAP LEAK
With CONSULT-II
1. Turn ignition switch ON.
2. Select “EVAP SYSTEM CLOSE” of “WORK SUPPORT” mode with CONSULT-II.
3. Touch “START” and apply pressure into the EVAP line until the pressure indicator reaches the middle of the bar graph.
CAUTION:
Do not use compressed air or a high pressure pump.
Do not exceed 4.12 kPa (0.042 kg/cm2 , 0.6 psi) of pres-
sure in the system.
4. Using EVAP leak detector, locate the EVAP leak. For the leak detector, refer to the instruction manual for more details.
Refer to EC-700, "
EVAPORATIVE EMISSION LINE DRAWING"
.
OK or NG
OK >> GO TO 11.
NG >> Repair or replace.
PBIB3238E
SEF916U
PEF917U
SEF200U
Page 2497 of 4462
![INFINITI FX35 2006 Service Manual DTC P0455 EVAP CONTROL SYSTEM EC-1113
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
10. CHECK FOR EVAP LEAK
Without CONSULT-II
1. Turn ignition switch OFF INFINITI FX35 2006 Service Manual DTC P0455 EVAP CONTROL SYSTEM EC-1113
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
10. CHECK FOR EVAP LEAK
Without CONSULT-II
1. Turn ignition switch OFF](/img/42/57019/w960_57019-2496.png)
DTC P0455 EVAP CONTROL SYSTEM EC-1113
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
10. CHECK FOR EVAP LEAK
Without CONSULT-II
1. Turn ignition switch OFF.
2. Apply 12 volts DC to EVAP canister vent control valve. The valve will close. (Continue to apply 12 volts until the end of test.)
3. Pressurize the EVAP line using pressure pump with 1.3 to 2.7 kPa (10 to 20 mmHg, 0.39 to 0.79 inHg), then remove pump and EVAP service port adapter.
CAUTION:
Do not use compressed air or a high pressure pump.
Do not exceed 4.12 kPa (0.042 kg/cm2 , 0.6 psi) of pressure in the system.
4. Using EVAP leak detector, locate the EVAP leak. For the leak detector, refer to the instruction manual for more details. Refer
to EC-700, "
EVAPORATIVE EMISSION LINE DRAWING" .
OK or NG
OK >> GO TO 12.
NG >> Repair or replace.
11 . CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
With CONSULT-II
1. Disconnect vacuum hose to EVAP canister purge volume control solenoid valve at EVAP service port.
2. Start engine.
3. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode.
4. Touch “Qu” on CONSULT-II screen to increase “PURG VOL CONT/V” opening to 100%.
5. Check vacuum hose for vacuum when revving engine up to 2,000 rpm.
OK or NG
OK >> GO TO 14.
NG >> GO TO 13.
PBIB1522E
SEF200U
PBIB1678E
Page 2498 of 4462
![INFINITI FX35 2006 Service Manual EC-1114
[VK45DE]
DTC P0455 EVAP CONTROL SYSTEM
Revision: 2006 December 2006 FX35/FX45
12. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
Without CONSULT-II
1. Start engine and INFINITI FX35 2006 Service Manual EC-1114
[VK45DE]
DTC P0455 EVAP CONTROL SYSTEM
Revision: 2006 December 2006 FX35/FX45
12. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
Without CONSULT-II
1. Start engine and](/img/42/57019/w960_57019-2497.png)
EC-1114
[VK45DE]
DTC P0455 EVAP CONTROL SYSTEM
Revision: 2006 December 2006 FX35/FX45
12. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Stop engine.
3. Disconnect vacuum hose to EVAP canister purge volume control solenoid valve at EVAP service port.
4. Start engine and let it idle for at least 80 seconds.
5. Check vacuum hose for vacuum when revving engine up to 2,000 rpm.
OK or NG
OK >> GO TO 15.
NG >> GO TO 13.
13. CHECK VACUUM HOSE
Check vacuum hoses for clogging or disconnection. Refer to EC-768, "
Vacuum Hose Drawing" .
OK or NG
OK (With CONSULT-II)>>GO TO 14.
OK (Without CONSULT-II)>>GO TO 15.
NG >> Repair or reconnect the hose.
14. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-II
1. Start engine.
2. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode with CONSULT-II. Check that engine speed varies according to the
valve opening.
OK or NG
OK >> GO TO 16.
NG >> GO TO 15.
15. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Refer to EC-1076, "
Component Inspection" .
OK or NG
OK >> GO TO 16.
NG >> Replace EVAP canister purge volume control solenoid valve.
16. CHECK FUEL TANK TEMPERATURE SENSOR
Refer to EC-1002, "
Component Inspection" .
OK or NG
OK >> GO TO 17.
NG >> Replace fuel level sensor unit. Vacuum should exist.
PBIB1678E