Color wire INFINITI M35 2006 Factory Service Manual

INFINITI M35 2006 Factory Service Manual M35 2006 INFINITI INFINITI https://www.carmanualsonline.info/img/42/57023/w960_57023-0.png INFINITI M35 2006 Factory Service Manual

Page 1760 of 5621

INFINITI M35 2006  Factory Service Manual DTC P0102, P0103 MAF SENSOR
EC-217
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2006 January2006 M35/M45
Specification data are reference values and are measured between each terminal and ground.
CAUT

Page 1777 of 5621

INFINITI M35 2006  Factory Service Manual EC-234
[VQ35DE]
DTC P0122, P0123 TP SENSOR
Revision: 2006 January2006 M35/M45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground

Page 1793 of 5621

INFINITI M35 2006  Factory Service Manual EC-250
[VQ35DE]
DTC P0130, P0150 A/F SENSOR 1
Revision: 2006 January2006 M35/M45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by

Page 1795 of 5621

INFINITI M35 2006  Factory Service Manual EC-252
[VQ35DE]
DTC P0130, P0150 A/F SENSOR 1
Revision: 2006 January2006 M35/M45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by

Page 1802 of 5621

INFINITI M35 2006  Factory Service Manual DTC P0131, P0151 A/F SENSOR 1
EC-259
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2006 January2006 M35/M45
Specification data are reference values and are measured between each terminal and ground.
Pu

Page 1804 of 5621

INFINITI M35 2006  Factory Service Manual DTC P0131, P0151 A/F SENSOR 1
EC-261
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2006 January2006 M35/M45
Specification data are reference values and are measured between each terminal and ground.
Pu

Page 1811 of 5621

INFINITI M35 2006  Factory Service Manual EC-268
[VQ35DE]
DTC P0132, P0152 A/F SENSOR 1
Revision: 2006 January2006 M35/M45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by

Page 1813 of 5621

INFINITI M35 2006  Factory Service Manual EC-270
[VQ35DE]
DTC P0132, P0152 A/F SENSOR 1
Revision: 2006 January2006 M35/M45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by

Page 1821 of 5621

INFINITI M35 2006  Factory Service Manual EC-278
[VQ35DE]
DTC P0133, P0153 A/F SENSOR 1
Revision: 2006 January2006 M35/M45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by

Page 1823 of 5621

INFINITI M35 2006  Factory Service Manual EC-280
[VQ35DE]
DTC P0133, P0153 A/F SENSOR 1
Revision: 2006 January2006 M35/M45
Specification data are reference values and are measured between each terminal and ground.