steering INFINITI Q50 HYBRID 2015 Dismantling Guide

INFINITI Q50 HYBRID 2015 Dismantling Guide Q50 HYBRID 2015 INFINITI INFINITI https://www.carmanualsonline.info/img/42/35021/w960_35021-0.png INFINITI Q50 HYBRID 2015 Dismantling Guide

Page 20 of 55

INFINITI Q50 HYBRID 2015  Dismantling Guide 3-4 How to Handle a Damaged Vehicle 
3-4.1 High Voltage System Shut-Down Procedure 
Any of the following procedures can shut down the high voltage system. The dismantling operation canonly 
begin afte

Page 21 of 55

INFINITI Q50 HYBRID 2015  Dismantling Guide Powering Down the High Voltage System 
The high voltage system can be shut down with any 1 of the following procedures:• Turn OFF the power switch and disconnect the 12-volt battery. Refer to
Primar

Page 24 of 55

INFINITI Q50 HYBRID 2015  Dismantling Guide Alternate Procedure 1 (Disconnect Underhood Fuse Panel) 
NOTE:Before disconnecting the underhood fuse panel and the negative (-) battery cable, if 
necessary, lower the windows, adjust the steering co

Page 27 of 55

INFINITI Q50 HYBRID 2015  Dismantling Guide Alternate Procedure 2 (Remove Service Plug)
DANGER
•Do not remove the service plug without always wearing appropriate Personal
Protective Equipment (PPE) to help protect the dismantler from serious

Page 37 of 55

INFINITI Q50 HYBRID 2015  Dismantling Guide 4-1 Jump Starting Procedures 
NOTE:Jumper cable connections under the hood of the Q50 HYBRID are not connected directly to 
a battery. They are connected to chassis ground and a fuse box terminal. Ref