INFINITI Q50 HYBRID 2017  First responder´s Guide 1. About the INFINITI Q50 HYBRID
This
hybrid electric vehicle (HEV) uses two types of batteries. One is a 12-volt battery that is the same as
the battery in vehicles powered by internal combustion eng

Page 7 of 43

INFINITI Q50 HYBRID 2017  First responder´s Guide 1-1.2 Interior
Interior
components referenced in this manual are as follows:
A. Assist charge gauge B. Energy flow display *1 C. READY indicator (green)
D. Energy flow display *1 E. Trunk lid release

Page 10 of 43

INFINITI Q50 HYBRID 2017  First responder´s Guide 2. Basic High-voltage System and 12-Volt System Information
2-1
Battery Information
The Q50 HYBRID utilizes two batteries in order to supply both high and low voltage.
2-1.1 12-Volt Battery • The Q5

Page 12 of 43

INFINITI Q50 HYBRID 2017  First responder´s Guide No. Component
LocationDescription
� T
raction Motor
Inverter
Engine compartment
(right rear side)Converts the DC power stored in the high-
voltage battery to three-phase AC power and
controls motor to

Page 14 of 43

INFINITI Q50 HYBRID 2017  First responder´s Guide 2-5 High-voltage Safety System
The
high-voltage safety system is intended to help keep vehicle occupants and emergency responders safe
from high-voltage electricity. • A high-voltage fuse provides s

Page 20 of 43

INFINITI Q50 HYBRID 2017  First responder´s Guide 3-3.1 High-voltage System Shut-Down Procedure
Any
of the following procedures can shut down the high-voltage system. The first response operation
should only begin after shutting down the high-voltage

Page 21 of 43

INFINITI Q50 HYBRID 2017  First responder´s Guide Powering Down the High-voltage System
The
high-voltage system can be shut down with any 1 of the following procedures:• Turn OFF the power switch and disconnect the 12-volt battery. Refer to Primary

Page 22 of 43

INFINITI Q50 HYBRID 2017  First responder´s Guide 5. Open the trunk using any of the following:
NO TE:
The trunk release power cancel switch must be in the
ON position in order for the trunk to be opened
using any of the methods below.
a. push-button

Page 25 of 43

INFINITI Q50 HYBRID 2017  First responder´s Guide 4. Disengage pawls (A) of underhood fuse panel cover
and remove underhood fuse panel cover (1) .
NOTE: : Arrow in illustration depicts vehicle front
direction.
5.

Pull underhood fuse panel (1) out by

Page 26 of 43

INFINITI Q50 HYBRID 2017  First responder´s Guide b. trunk button on the Infiniti Intelligent Key
[press for longer than one (1) second].
c. trunk open request switch (located above license plate)*.
* You must have the Infiniti Intelligent Key
within