trunk INFINITI Q50 HYBRID 2018 First responder´s Guide

INFINITI Q50 HYBRID 2018 First responder´s Guide Q50 HYBRID 2018 INFINITI INFINITI https://www.carmanualsonline.info/img/42/35039/w960_35039-0.png INFINITI Q50 HYBRID 2018 First responder´s Guide

Page 5 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide 1. About the INFINITI Q50 HYBRID
This
hybrid electric vehicle (HEV) uses two types of batteries. One is a 12-volt battery that is the same as
the battery in vehicles powered by internal combustion eng

Page 7 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide 1-1.2 Interior
Interior
components referenced in this manual are as follows:
A. Assist charge gauge B. Energy flow display *1 C. READY indicator (green)
D. Energy flow display *1 E. Trunk lid release

Page 10 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide 2. Basic High-voltage System and 12-Volt System Information
2-1
Battery Information
The Q50 HYBRID utilizes two batteries in order to supply both high and low voltage.
2-1.1 12-Volt Battery • The Q5

Page 12 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide No. Component
LocationDescription
� T
raction Motor Built-into the trans- mission Converts three-phase alternating current (AC)
power to drive power (torque) which propels
the vehicle.
� High-voltage

Page 15 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide • The high-voltage system and high-voltage capacitor may remain powered for up to
approximately 10 minutes after the vehicle is shut off. Personal Protective Equipment
(PPE) must always be worn when

Page 21 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide 3-3.1 High-voltage System Shut-Down Procedure
Any
of the following procedures can shut down the high-voltage system. The first response operation
should only begin after shutting down the high-voltage

Page 22 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide Powering Down the High-voltage System
The
high-voltage system can be shut down with any 1 of the following procedures:• Turn OFF the power switch and disconnect the 12-volt battery. Refer to Primary

Page 23 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide 5. Open the trunk using any of the following:
NO TE:
The trunk release power cancel switch must be in the
ON position in order for the trunk to be opened
using any of the methods below.
a. push-button

Page 26 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide 4. Disengage pawls (A) of underhood fuse panel cover and
remove underhood fuse panel cover (1) .
NOTE: : Arrow in illustration depicts vehicle front
direction.
5.

Pull underhood fuse panel (1) out by

Page 27 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide b. trunk button on the Infiniti Intelligent Key
[press for longer than one (1) second].
c. trunk open request switch (located above license plate)*.
* You must have the Infiniti Intelligent Key within
Page:   1-10 11-20 next >