2. Basic High Voltage Information
2-1
Battery Information
The Q70 HYBRID utilizes two batteries in order to supply both high and low voltage.
2-1.1 12V Battery • The Q70 HYBRID contains a conventional lead-acid 12Vbattery.
• The 12V battery is located in the trunk, left of Li-ion battery, concealed by trim cover.
• The 12V battery is charged by the Li-ion battery through the DC/DC converter.
2-1.2 Li-ion Battery • The Q70 HYBRID contains a Li-ion high voltage battery.
• The high voltage battery is mounted in the trunk areabehind the rear seat, enclosed in a metal case and
concealed by trim cover.
• The high voltage battery stores approximately 346 volts DC (400V max.) .
• A vent hose is provided to exhaust gasses outside the vehicle if necessary.
• An air vent is located on the rear parcel shelf for battery cooling.
The high voltage battery supplies power to the following: • High voltage harnesses
• DC/DC converter
• Traction motor inverter
• Traction motor
• Electric air conditioner compressor AAYIA0064ZZ
AAYIA0065ZZ
AAYIA0066ZZ
DG–10
Page 33 of 51

4. Jump Starting
T
o start the hybrid system with a booster battery, the instructions and precautions below must be followed. If done incorrectly, jump starting can lead to a 12V battery explosion, resulting in severe
personal
injury or death. It could also damage your vehicle.
Jump starting provides power to the 12V system to allow the electrical systems to operate. The electrical
systems must be operating to allow the Li-ion battery to be charged. Jump starting does not charge the
Li-ion battery.
Discharged 12V battery may cause the following issues: • The instrument cluster cannot be displayed while the ignition switch is turned ON. (The hybridsystem cannot start.)
• Headlamps, horn, etc. are weak. • To avoid electrical shock, the high voltage Li-ion battery CANNOT be jump started.
•
Explosive hydrogen gas is always present in the vicinity of the 12V battery. Keep all
sparks and flames away from the 12V battery. Make sure the vent tube is correctly
installed.
• Do not allow battery fluid to come into contact with eyes, skin, clothing or painted surfaces. Battery fluid is a corrosive sulfuric acid solution that can cause severe burns. If
the fluid comes into contact with anything, immediately flush the contacted area with
water.
• The booster battery must be rated at 12 volts. Use of an improperly rated battery can damage the vehicle.
• Whenever working on or near a 12V battery, always wear suitable eye protectors (for example, goggles or industrial safety spectacles) and remove rings, metal bands, or
any other jewelry. Do not lean over the 12V battery when jump starting.
• Do not attempt to jump start a frozen battery. It could explode and cause serious injury.
• Q70 HYBRID is equipped with an automatic cooling fan. It could come on at any time. Keep hands and other objects away from it.
• Always follow the jump starting instructions below. Failure to do so could result in damage to the charging system and cause personal injury.
DG–33
Page 40 of 51

6-2 Lithium-ion (Li-ion) Battery Pack Removal
6-2.1
Exploded View
1. Battery inlet duct A 2. Li-ion battery assembly 3. DC/DC converter outlet duct
4. Battery outlet duct B 5. Battery outlet duct A6. Battery inlet duct B
7. Battery cooling fan 8. DC/DC converter inlet duct
6-2.2 Removal Procedure 1. Remove the service plug. Refer to Alternate Procedure 2 (Remove Service Plug) (DG–25)
.
2.
Insert an appropriate tool into the gap between the trunk lamp case and front trunk trim panel to
remove the trunk lamp case.
3. Disconnect the trunk lamp harness connector.
4. Remove the trunk lid weather strip.
5. Remove the front trunk trim retainer clips. AAYIA0036ZZ
DG–40
Page 44 of 51

16. Remove the mounting nut (A) and then disconnect the
harness from the fuse box on the left side of the trunk
room.
17. Disconnect the brake power supply backup unit harness connector (A) and remove the ground cable mounting
bolts (B) . : Vehicle front
18.
Disconnect the high voltage harness connector (A) and
harness connector (B) . : Vehicle front
Touching high voltage components without wearing
appropriate
Personal Protective Equipment (PPE) will
cause electrocution. Immediately protect the terminals of the disconnected
high
voltage harness connector socket using insulated
tape so that they are not exposed.
19. Disconnect the Li-ion battery cooling fan motor harness connector. JSCIA0279ZZ
JSCIA0280ZZ
JSCIA0281ZZ
AAYIA0043ZZ
DG–44
Page 49 of 51

• Be careful that the engine crane does not contact
the trunk lid.
• Apply protection so that no scratches or other damage occurs on the vehicle body or trunk lid.
29. Remove the DC/DC converter inlet duct clips (A) and then the DC/DC converter inlet duct (1) . Touching high voltage components without wearing
appropriate
Personal Protective Equipment (PPE) will
cause electrocution.
30. Remove the battery cooling fan mounting bolts (A) and remove the battery cooling fan (1) . Touching high voltage components without wearing
appropriate
Personal Protective Equipment (PPE) will
cause electrocution. JSCIA0282ZZ
AAYIA0048ZZ
AAYIA0049ZZ