2-2 High Voltage-Related and 12-Volt-Related Component Locations and Descriptions
NOTE:Components with white number in black background are high voltage components.
No. Component Location Description
High Voltage Bat- tery Trunk area (behind
rear seat back) The high voltage battery stores and outputs
DC power (Maximum voltage 400V) needed to
propel the vehicle.
DC/DC Converter Trunk area (mounted
to top of high volt-
age battery) The DC/DC converter reduces the voltage of
the high voltage battery to provide power to
the 12-volt battery in order to operate the vehi-
cle’s electric components (headlights, audio
system, etc.) .
AAYIA0338ZZ
DG–11
4-1 Jump Starting Procedures
NOTE:Jumper cable connections under the hood of the Q70 HYBRID are not connected directly to
a battery. They are connected to chassis ground and a fuse box terminal. Refer to the
following instructions and the above illustration.
1. If the booster battery is in another vehicle (A) , position the two vehicles (A) and (B) to bring thebattery of booster vehicle (A) and the fuse box of jumped vehicle (B) into close proximity to eachother.
DO NOT allow the two vehicles to touch.
2. Apply the parking brake. Move the selector lever the P (Park) position. Switch off all unnecessary electrical systems (headlights, heater, air conditioner, etc.) .
3. Place the ignition switch in the “OFF” position.
• Always connect positive (+) to positive (+) and negative (-) to body ground (for example, as illustrated) , not to the 12-volt battery.
• Make sure the jumper cables do not touch moving parts in the engine compartment and that the cable clamps do not contact any other metal.
• If the hybrid system does not start right away, push the ignition switch to the OFF position and wait ten (10) seconds before trying again.
4. Connect the jumper cables in the sequence as illustrated [(1) , (2) , (3) , (4)].
5. Start the engine of the booster vehicle (A) and let it run for a few minutes.
6. Start the hybrid system of the jumped vehicle (B) in the normal manner.
7. After the hybrid system is started, carefully disconnect the jumper cables in the opposite sequence from that illustrated [(4) , (3) , (2) , (1)].
NOTE:
If it is not possible to turn the hybrid system ON by following this procedure, it is
recommended you contact an INFINITI retailer immediately.
8. Put the fuse cover and the engine compartment cover back to the original location.
AB
2+1
1234
+
3-4-
AAYIA0405ZZ
DG–35