battery INFINITI Q70 HYBRID 2017 First Responder´s

INFINITI Q70 HYBRID 2017 First Responder´s Q70 HYBRID 2017 INFINITI INFINITI https://www.carmanualsonline.info/img/42/35096/w960_35096-0.png INFINITI Q70 HYBRID 2017 First Responder´s

Page 2 of 42

INFINITI Q70 HYBRID 2017  First Responder´s Foreword
This
manual describes first response operations and related warnings and cautions for this vehicle.
This vehicle is equipped with a high voltage battery pack. Failure to follow recommended pr

Page 3 of 42

INFINITI Q70 HYBRID 2017  First Responder´s Table of Contents
FOREWORD
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FRG–2
INFINITI EMERGENCY CONTACT INFO

Page 5 of 42

INFINITI Q70 HYBRID 2017  First Responder´s 1. About the INFINITI Q70 HYBRID
This
hybrid electric vehicle (HEV) uses two types of batteries. One is a 12-volt battery that is the same as
the battery in vehicles powered by internal combustion eng

Page 10 of 42

INFINITI Q70 HYBRID 2017  First Responder´s 2. Basic High Voltage System and 12-Volt System Information
2-1
Battery Information
The Q70 HYBRID utilizes two batteries in order to supply both high and low voltage.
2-1.1 12-volt Battery • The Q7

Page 11 of 42

INFINITI Q70 HYBRID 2017  First Responder´s 2-2 High Voltage-Related and 12-Volt-Related Component Locations and
Descriptions
NO
TE:
Components with white number in black background are high voltage components. No. Component
LocationDescription

Page 12 of 42

INFINITI Q70 HYBRID 2017  First Responder´s No. Component
LocationDescription
� Service
Plug Trunk area (belowparcel shelf; behind
access door in trim
panel) This is used to disable the high voltage system.
� 12-volt Battery Trunk area (below
p

Page 13 of 42

INFINITI Q70 HYBRID 2017  First Responder´s 2-4 High Voltage Safety Measures
Circuit insulation
The high voltage positive (+) and negative (-) circuits are insulated
from the metal chassis.
Reducing the risk of electrocution The high voltage co

Page 14 of 42

INFINITI Q70 HYBRID 2017  First Responder´s 2-5 High Voltage Safety System
The
high voltage safety system is intended to help keep vehicle occupants and emergency responders safe
from high voltage electricity. • A high voltage fuse provides s

Page 15 of 42

INFINITI Q70 HYBRID 2017  First Responder´s 2-6 High Voltage Circuit Shut-Off System
This
vehicle is equipped with a system to shut off the current from the high voltage battery by the following
methods: Service plug
Positioned in the center ar

Page 17 of 42

INFINITI Q70 HYBRID 2017  First Responder´s 3-1 Preparation Items
Preparation Items
Specification Purpose
PPE (personal protective
equipment): Up to 1,000V
For protection from high voltage
electrical shock.
Insulated gloves Insulated shoes
–
Page:   1-10 11-20 21-30 next >