ignition INFINITI QX4 2001 Factory Service Manual

INFINITI QX4 2001 Factory Service Manual QX4 2001 INFINITI INFINITI https://www.carmanualsonline.info/img/42/57027/w960_57027-0.png INFINITI QX4 2001 Factory Service Manual

Page 889 of 2395

INFINITI QX4 2001  Factory Service Manual SEF565X
DTC Confirmation ProcedureNBEC0219
SEF566X
SEF874X
SEF567X
NOTE:
IIf DTC P0440 or P1440 is displayed with P1448, perform
trouble diagnosis for DTC P1448 first. (See EC-573.)
IIf ªDTC Confirma

Page 890 of 2395

INFINITI QX4 2001  Factory Service Manual IIf P0440, P1440 and P1447 are not displayed on the screen,
go to the following step.
10) Select ªMODE 1º with GST.
IIf SRT of EVAP system is set, the result will be OK.
IIf SRT of EVAP system is no

Page 893 of 2395

INFINITI QX4 2001  Factory Service Manual 6 CHECK FOR EVAP LEAK
With CONSULT-II
1. Turn ignition switch ªONº.
2. Select ªEVAP SYSTEM CLOSEº of ªWORK SUPPORTº mode with CONSULT-II.
3. Touch ªSTARTº and apply pressure into the EVAP line

Page 894 of 2395

INFINITI QX4 2001  Factory Service Manual 7 CHECK FOR EVAP LEAK
Without CONSULT-II
1. Turn ignition switch ªOFFº.
2. Apply 12 volts DC to EVAP canister vent control valve. The valve will close. (Continue to apply 12 volts until the end of
t

Page 899 of 2395

INFINITI QX4 2001  Factory Service Manual 18 CHECK ABSOLUTE PRESSURE SENSOR
1. Remove absolute pressure sensor with its harness connector connected.
SEF961Y
2. Remove hose from absolute pressure sensor.
3. Install a vacuum pump to absolute pr

Page 900 of 2395

INFINITI QX4 2001  Factory Service Manual 20 CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
1. Remove EVAP control system pressure sensor with its harness connector connected.
CAUTION:
INever apply force to the air hole protector of the sensor if

Page 902 of 2395

INFINITI QX4 2001  Factory Service Manual DescriptionNBEC0221SYSTEM DESCRIPTIONNBEC0221S01
Sensor Input Signal to ECMECM
functionActuator
Crankshaft position sensor (POS) Engine speed (POS signal)
EVAP can-
ister purge
flow controlEVAP canist

Page 904 of 2395

INFINITI QX4 2001  Factory Service Manual SEF058Y
DTC Confirmation ProcedureNBEC0225NOTE:
If ªDTC Confirmation Procedureº has been previously conducted,
always turn ignition switch ªOFFº and wait at least 10 seconds
before conducting the

Page 906 of 2395

INFINITI QX4 2001  Factory Service Manual Diagnostic ProcedureNBEC0227
1 CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch ªOFFº.
2. Disconnect EVAP canister purge volume control solenoid v

Page 907 of 2395

INFINITI QX4 2001  Factory Service Manual 3 CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT
FOR OPEN AND SHORT
1. Turn ignition switch ªOFFº.
2. Disconnect ECM harness connector.
3. Check harness continuity bet