INFINITI QX4 2001  Factory Service Manual 17 ADJUSTMENT THROTTLE POSITION SWITCH CLOSED POSITION-II
1. Temporarily tighten sensor body fixing bolts as follows.
IGradually move the sensor body clockwise and stop it when the continuity comes to

Page 890 of 2395

INFINITI QX4 2001  Factory Service Manual IIf P0440, P1440 and P1447 are not displayed on the screen,
go to the following step.
10) Select ªMODE 1º with GST.
IIf SRT of EVAP system is set, the result will be OK.
IIf SRT of EVAP system is no

Page 932 of 2395

INFINITI QX4 2001  Factory Service Manual 8) Stop vehicle.
9) Select ªMODE 3º with GST.
IIf P0455 is displayed on the screen, go to ªDiagnostic
Procedureº, EC-397.
IIf P0440 or P1440 is displayed on the screen, go to ªDiagnos-
tic Proced

Page 1587 of 2395

INFINITI QX4 2001  Factory Service Manual ªERROR HISTORYº TABLE=NBEL0232S02
Detected items Description Diagnosis/service procedureRefer-
ence
page
Gyro sensor disconnectedCommunications malfunction between
display & NAVI control unit and in

Page 1807 of 2395

INFINITI QX4 2001  Factory Service Manual RHA273D
SERVICE COUPLERSNBHA0006S06Never attempt to connect HFC-134a (R-134a) service couplers to
an CFC-12 (R-12) A/C system. The HFC-134a (R-134a) couplers
will not properly connect to the CFC-12 (R

Page 1854 of 2395

INFINITI QX4 2001  Factory Service Manual STEP-BY-STEP PROCEDURENBHA0021S05With Navigation SystemNBHA0021S0501
1 SET IN SELF-DIAGNOSTIC MODE
1. Turn ignition switch ON.
2. Set in self-diagnostic mode as follows. Within 10 seconds after starti

Page 1863 of 2395

INFINITI QX4 2001  Factory Service Manual AUXILIARY MECHANISM: TEMPERATURE SETTING TRIMMER=NBHA0021S06With Navigation SystemNBHA0021S0601The trimmer compensates for differences in range of±3ÉC (±6ÉF) between temperature setting (displayed

Page 1868 of 2395

INFINITI QX4 2001  Factory Service Manual RHA461GA
SHA278FA
6. Check Temperature IncreaseNBHA0019S0206Without Navigation System
IPress the temperature increase button until 32ÉC (85ÉF) is
displayed.
ICheck for hot air at discharge air outle

Page 1884 of 2395

INFINITI QX4 2001  Factory Service Manual Air Mix Door Control SpecificationNBHA0059S03
RHA137G
RHA849E
COMPONENT DESCRIPTIONNBHA0060The air mix door motor is attached to the heater unit. It rotates so
that the air mix door is opened or close