fuel reserve INFINITI QX56 2004 Factory Service Manual
[x] Cancel search | Manufacturer: INFINITI, Model Year: 2004, Model line: QX56, Model: INFINITI QX56 2004Pages: 3371, PDF Size: 78.5 MB
Page 1117 of 3371

DI-14
COMBINATION METERS
Revision: August 20072004 QX56
Next test requested Sc1XXDisplays 8-bit software
configuration value in Hex
format.Bit Coding
7-3 = reserved for future use
2 = TCS/VDC 0 = not present
1 = present
1 = Shift type 0 = Column shift
1 = Floor shift
0 = ICC 0 = not present
1 = present
Next test requested Sc2XXDisplays 8-bit software
configuration value in Hex
format.Bit coding
7-0 = Reserved for future use
Next test requested EprXXDisplays 8-bit software
configuration value in Hex
format.Bit Coding
7-2 = reserved for future use
1 = A/T Oil Temp (gauge)
0 = not present
1 = present
1 = Odo Units 0 = kilometers
1 = miles
Next test requested 1nFXXDisplays 8-bit market info
value in Hex format.$31 = USA
$2A = Canada
Next test requested cYLXXDisplays 8-bit engine con-
figuration value in Hex
format.$08 = 8 cylinder
$06 = 6 cylinder
Next test requested FFXXXXDisplays 16-bit fuel flow
constant "Q" in tenths of
cc/min in Hex format.$0000 - $FFFF
Next test requested tFDisplays 16-bit tire factor
"A" in hundredths in Hex
format.$0000 - $FFFF
Next test requested ot1XXDisplays oil pressure tell-
tale "on" threshold in A/D
counts in Hex format.$00 - $FF
Next test requested ot0XXDisplays oil pressure tell-
tale "off" threshold in A/D
counts in Hex format.$00 - $FF
Next test requested XXXXXRaw uncompensated
english speed value in
hundredths of MPH.
Speedometer indicates
present speed.Will display "-----" if message is
not received. Will display
"99999" if data received is
invalid
Next test requested XXXXXRaw uncompensated
metric speed value in
hundredths of KPH.
Speedometer indicates
present speed.Will display "-----" if message is
not received. Will display
"99999" if data received is
invalid
Next test requested tXXXXTachometer value in
RPM. Tachometer indi-
cates present RPM.Will display "-----" if message is
not received.
Next test requested F1 XXXXPresent ratioed fuel level
A/D input 1 in decimal for-
mat. Fuel gauge indicates
present filtered level.000-009 = Short circuit
010-254 = Normal range
255 = Open circuit
--- = Missing 5 seconds
Next test requested XXXCLast temperature gauge
input value in degrees C.
Temperature gauge indi-
cates present filtered tem-
perature.Will display "---"C if message is
not received.
Will display "999" if data
received is invalid. Event Odometer Display Description of Test/Data Notes: