engine INFINITI QX56 2010 Factory Service Manual
[x] Cancel search | Manufacturer: INFINITI, Model Year: 2010, Model line: QX56, Model: INFINITI QX56 2010Pages: 4210, PDF Size: 81.91 MB
Page 1564 of 4210
![INFINITI QX56 2010 Factory Service Manual P0420, P0430 THREE WAY CATALYST FUNCTIONEC-211
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
Check the following items. Refer to
EC-13, "Basic Inspection".
OK or NG
OK >> GO TO 5.
INFINITI QX56 2010 Factory Service Manual P0420, P0430 THREE WAY CATALYST FUNCTIONEC-211
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
Check the following items. Refer to
EC-13, "Basic Inspection".
OK or NG
OK >> GO TO 5.](/img/42/57032/w960_57032-1563.png)
P0420, P0430 THREE WAY CATALYST FUNCTIONEC-211
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
Check the following items. Refer to
EC-13, "Basic Inspection".
OK or NG
OK >> GO TO 5.
NG >> Follow the EC-13, "
Basic Inspection".
5.CHECK FUEL INJECTOR
1. Stop engine and then turn ignition switch ON.
2. Check voltage between ECM terminals 21, 22, 23, 40, 41, 42, 44, 63 and ground with CONSULT-III or tester.
Refer to Wiring Diagram for fuel injector, EC-435, "
Wiring Dia-
gram - ENGINE CONTROL SYSTEM -".
OK or NG
OK >> GO TO 6.
NG >> Perform EC-407, "
Diagnosis Procedure".
6.CHECK FUNCTION OF IGNITION COIL-I
CAUTION:
Do the following procedure in the place where ventilation is good without the combustible.
1. Turn ignition switch OFF.
2. Remove fuel pump fuse in IPDM E/R to release fuel pressure.
NOTE:
Do not use CONSULT-III to release fuel pressure, or fuel pres-
sure applies again during the following procedure.
3. Start engine.
4. After engine stalls, crank it two or three times to release all fuel pressure.
5. Turn ignition switch OFF.
6. Remove all ignition coil harness connectors to avoid the electri- cal discharge from the ignition coils.
7. Remove ignition coil and spark plug of the cylinder to be checked.
8. Crank engine for 5 seconds or more to remove combustion gas in the cylinder.
9. Connect spark plug and harness connector to ignition coil.
10. Fix ignition coil using a rope etc. with gap of 13 - 17 mm (0.52 - 0.66 in) between the edge of the spark plug and grounded metal
portion as shown in the figure.
11. Crank engine for about 3 seconds, and check whether spark is
generated between the spark plug and the grounded metal por-
tion.
CAUTION:
• During the operation, always stay 0.5 m (1.6 ft) or moreaway from the spark plug and the ignition coil. Be careful
not to get an electrical sh ock while checking, because the
electrical discharge voltage becomes 20 kV or more.
• It might cause to damage the igni tion coil if the gap of more than 17 mm (0.66 in) is taken.
NOTE:
When the gap is less than 13 mm (0.52 in), a spark might be generated even if the coil is malfunc-
tioning.
Items Specifications
Target idle speed 650 ± 50 rpm (in P or N position)
Ignition timing 15 ± 5° BTDC (in P or N position)
Battery voltage should exist.
PBIB1527E
Spark should be generated.
BBIA0380E
PBIB2325E
Revision: April 20092010 QX56
Page 1565 of 4210
![INFINITI QX56 2010 Factory Service Manual EC-212
< COMPONENT DIAGNOSIS >[VK56DE]
P0420, P0430 THREE WAY CATALYST FUNCTION
OK or NG
OK >> GO TO 10.
NG >> GO TO 7.
7.CHECK FUNCTION OF IGNITION COIL-II
1. Turn ignition switch OFF.
2. Disconnect INFINITI QX56 2010 Factory Service Manual EC-212
< COMPONENT DIAGNOSIS >[VK56DE]
P0420, P0430 THREE WAY CATALYST FUNCTION
OK or NG
OK >> GO TO 10.
NG >> GO TO 7.
7.CHECK FUNCTION OF IGNITION COIL-II
1. Turn ignition switch OFF.
2. Disconnect](/img/42/57032/w960_57032-1564.png)
EC-212
< COMPONENT DIAGNOSIS >[VK56DE]
P0420, P0430 THREE WAY CATALYST FUNCTION
OK or NG
OK >> GO TO 10.
NG >> GO TO 7.
7.CHECK FUNCTION OF IGNITION COIL-II
1. Turn ignition switch OFF.
2. Disconnect spark plug and connect a known-good spark plug.
3. Crank engine for about 3 seconds, and recheck whether spark is generated between the spark plug and the grounded metal portion.
OK or NG
OK >> GO TO 8.
NG >> Check ignition coil, power transistor and their circuits. Refer to EC-407, "
Diagnosis Procedure".
8.CHECK SPARK PLUG
Check the initial spark plug for fouling, etc.
OK or NG
OK >> Replace malfunctioning spark plug(s) with standard type one(s). For spark plug type, refer to EM-16, "
Removal
and Installation".
NG >> 1. Repair or clean spark plug.
2. GO TO 9.
9.CHECK FUNCTION OF IGNITION COIL-III
1. Reconnect the initial spark plugs.
2. Crank engine for about three seconds, and recheck whether spark is generated between the spark plug
and the grounded portion.
OK or NG
OK >> INSPECTION END
NG >> Replace malfunctioning spark plug(s) with standard type one(s). For spark plug type, refer to EM-
16, "Removal and Installation".
10.CHECK FUEL INJECTOR
1. Turn ignition switch OFF.
2. Remove fuel injector assembly. Refer to EM-40, "
Removal and Installation".
Keep fuel hose and all fuel injectors connected to fuel injector gallery.
3. Disconnect all ignition coil harness connectors.
4. Reconnect all fuel injector harness connectors disconnected.
5. Turn ignition switch ON. Make sure fuel does not drip from fuel injector.
OK or NG
OK (Does not drip.)>>GO TO 11.
NG (Drips.)>>Replace the fuel injector(s) from which fuel is dripping.
11 .CHECK INTERMITTENT INCIDENT
Refer to GI-35, "
How to Check Terminal" and GI-38, "Intermittent Incident".
Trouble is fixed.>> INSPECTION END
Trouble is not fixed.>>Replace three way catalyst assembly. Spark should be generated.
SEF156I
Spark should be generated.
Revision: April 20092010 QX56
Page 1567 of 4210
![INFINITI QX56 2010 Factory Service Manual EC-214
< COMPONENT DIAGNOSIS >[VK56DE]
P0441 EVAP CONTROL SYSTEM
TESTING CONDITION:
Always perform test at a temperature of 5
°C (41 °F) or more.
WITH CONSULT-III
1. Start engine and warm it up to INFINITI QX56 2010 Factory Service Manual EC-214
< COMPONENT DIAGNOSIS >[VK56DE]
P0441 EVAP CONTROL SYSTEM
TESTING CONDITION:
Always perform test at a temperature of 5
°C (41 °F) or more.
WITH CONSULT-III
1. Start engine and warm it up to](/img/42/57032/w960_57032-1566.png)
EC-214
< COMPONENT DIAGNOSIS >[VK56DE]
P0441 EVAP CONTROL SYSTEM
TESTING CONDITION:
Always perform test at a temperature of 5
°C (41 °F) or more.
WITH CONSULT-III
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and let it idle for at least 70 seconds.
4. Select “PURG FLOW P0441” of “EVAPORATIVE SYSTEM” in “DTC WORK SUPPORT” mode with CON-
SULT-III.
5. Touch “START”. If “COMPLETED” is displayed, go to step 7.
6. When the following conditions are met, “TESTING” will be displayed on the CONSULT-III screen. Maintain
the conditions continuously until “TESTING” changes to “COMPLETED”. (It will take at least 35 seconds.)
If “TESTING” is not changed for a long time, retry from step 2.
7. Make sure that “OK” is displayed after touching “ SELF-DIAG RESULTS”. If “NG” is displayed, refer to EC-
214, "Diagnosis Procedure".
Overall Function CheckINFOID:0000000005149236
Use this procedure to check the overall monitoring func tion of the EVAP control system purge flow monitoring.
During this check, a 1st trip DTC might not be confirmed.
WITH GST
1. Lift up drive wheels.
2. Start engine (VDC switch OFF) and warm it up to normal operating temperature.
3. Turn ignition switch OFF, wait at least 10 seconds.
4. Start engine and wait at least 70 seconds.
5. Set voltmeter probes to ECM terminals 32 (EVAP control system pressure sensor signal) and ground.
6. Check EVAP control system pre ssure sensor value at idle speed
and note it.
7. Establish and maintain the following conditions for at least 1 minute.
8. Verify that EVAP control system pressure sensor value stays 0.1 V less than the value at idle speed (mea- sured at step 6) for at least 1 second.
9. If NG, go to EC-214, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000005149237
1.CHECK EVAP CANISTER
1. Turn ignition switch OFF.
2. Check EVAP canister for cracks.
OK or NG
OK (With CONSULT-III)>>GO TO 2.
Selector lever Suitable position
VHCL SPEED SE 32 - 120 km/h (20 - 75 MPH)
ENG SPEED 500 - 3,000 rpm
B/FUEL SCHDL 1.0 - 12.0 msec
COOLAN TEMP/S More than 0°C (32 °F)
Air conditioner switch ON
Headlamp switch ON
Rear window defogger switch ON
Engine speed Approx. 3,000 rpm
Gear position Any position other than P, N or R
PBIB1109E
Revision: April 20092010 QX56
Page 1568 of 4210
![INFINITI QX56 2010 Factory Service Manual P0441 EVAP CONTROL SYSTEMEC-215
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
OK (Without CONSULT-III)>>GO TO 3.
NG >> Replace EVAP canister.
2.CHECK PURGE FLOW
With CONSULT-III
1 INFINITI QX56 2010 Factory Service Manual P0441 EVAP CONTROL SYSTEMEC-215
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
OK (Without CONSULT-III)>>GO TO 3.
NG >> Replace EVAP canister.
2.CHECK PURGE FLOW
With CONSULT-III
1](/img/42/57032/w960_57032-1567.png)
P0441 EVAP CONTROL SYSTEMEC-215
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
OK (Without CONSULT-III)>>GO TO 3.
NG >> Replace EVAP canister.
2.CHECK PURGE FLOW
With CONSULT-III
1. Disconnect vacuum hose connected to EVAP canister purge volume control solenoid valve at EVAP ser-
vice port and install vacuum gauge. For the location of EVAP service port, refer to EC-37, "
Description".
2. Start engine and let it idle.
3. Select “PURG VOL CONT/V” in “ACTIVE TEST” mode with CONSULT-III.
4. Rev engine up to 2,000 rpm.
5. Touch “Qd” and “Qu” on CONSULT-III screen to adjust “PURG VOL CONT/V” opening and check vacuum
existence.
OK or NG
OK >> GO TO 7.
NG >> GO TO 4.
3.CHECK PURGE FLOW
Without CONSULT-III
1. Start engine and warm it up to normal operating temperature.
2. Stop engine.
3. Disconnect vacuum hose connected to EVAP canister purge volume control solenoid valve at EVAP ser-
vice port and install vacuum gauge. For the location of EVAP service port, refer to EC-37, "
Description".
4. Start engine and let it idle.
Do not depress accelerator pedal even slightly.
5. Check vacuum gauge indication before 60 seconds passed after starting engine.
6. Revving engine up to 2,000 rpm after 100 seconds passed after starting engine.
OK or NG
OK >> GO TO 7.
NG >> GO TO 4.
4.CHECK EVAP PURGE LINE
1. Turn ignition switch OFF.
2. Check EVAP purge line for improper connection or disconnection. Refer to EC-37, "
Description".
OK or NG
OK >> GO TO 5.
NG >> Repair it.
5.CHECK EVAP PURGE HOSE AND PURGE PORT
PURG VOL CONT/V Vacuum
100% Should exist.
0% Should not exist.
Vacuum should not exist.
Vacuum should exist.
Revision: April 20092010 QX56
Page 1569 of 4210
![INFINITI QX56 2010 Factory Service Manual EC-216
< COMPONENT DIAGNOSIS >[VK56DE]
P0441 EVAP CONTROL SYSTEM
1. Disconnect purge hoses connected to EVAP service port
A and
EVAP canister purge volume control solenoid valve B.
2. Blow air into INFINITI QX56 2010 Factory Service Manual EC-216
< COMPONENT DIAGNOSIS >[VK56DE]
P0441 EVAP CONTROL SYSTEM
1. Disconnect purge hoses connected to EVAP service port
A and
EVAP canister purge volume control solenoid valve B.
2. Blow air into](/img/42/57032/w960_57032-1568.png)
EC-216
< COMPONENT DIAGNOSIS >[VK56DE]
P0441 EVAP CONTROL SYSTEM
1. Disconnect purge hoses connected to EVAP service port
A and
EVAP canister purge volume control solenoid valve B.
2. Blow air into each hose and EVAP purge port C.
3. Check that air flows freely.
OK or NG
OK (With CONSULT-III)>>GO TO 6.
OK (Without CONSULT-III)>>GO TO 7.
NG >> Repair or clean hoses and/or purge port.
6.CHECK EVAP CANISTER PURGE VO LUME CONTROL SOLENOID VALVE
With CONSULT-III
1. Start engine.
2. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode with CONSULT-III. Check that engine speed var- ies according to the valve opening.
OK or NG
OK >> GO TO 8.
NG >> GO TO 7.
7.CHECK EVAP CANISTER PURGE VO LUME CONTROL SOLENOID VALVE
Refer to EC-233, "
Component Inspection".
OK or NG
OK >> GO TO 8.
NG >> Replace EVAP canister purge volume control solenoid valve.
8.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR
1. Disconnect EVAP control system pressure sensor harness connector.
2. Check connectors for water.
OK or NG
OK >> GO TO 9.
NG >> Replace EVAP control system pressure sensor.
9.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR FUNCTION
Refer to DTC Confirmation Procedure for DTC P0452, EC-245, "
DTC Confirmation Procedure" and P0453,
EC-249, "
DTC Confirmation Procedure".
OK or NG
OK >> GO TO 10.
NG >> Replace EVAP control system pressure sensor.
10.CHECK RUBBER TUBE FOR CLOGGING
1. Disconnect rubber tube connected to EV AP canister vent control valve.
SEF367U
SEF368U
Water should not exist.
Revision: April 20092010 QX56
Page 1571 of 4210
![INFINITI QX56 2010 Factory Service Manual EC-218
< COMPONENT DIAGNOSIS >[VK56DE]
P0442 EVAP CONTROL SYSTEM
P0442 EVAP CONTROL SYSTEM
On Board Diagn
osis LogicINFOID:0000000005149238
This diagnosis detects leaks in the EVAP purge line using en INFINITI QX56 2010 Factory Service Manual EC-218
< COMPONENT DIAGNOSIS >[VK56DE]
P0442 EVAP CONTROL SYSTEM
P0442 EVAP CONTROL SYSTEM
On Board Diagn
osis LogicINFOID:0000000005149238
This diagnosis detects leaks in the EVAP purge line using en](/img/42/57032/w960_57032-1570.png)
EC-218
< COMPONENT DIAGNOSIS >[VK56DE]
P0442 EVAP CONTROL SYSTEM
P0442 EVAP CONTROL SYSTEM
On Board Diagn
osis LogicINFOID:0000000005149238
This diagnosis detects leaks in the EVAP purge line using engine intake manifold vacuum.
If pressure does not increase, the ECM will check for leaks in the line between the fuel tank and EVAP canister
purge volume control solenoid valve, under the following “Vacuum test” conditions.
The EVAP canister vent control valve is closed to shut the EVAP purge line off. The EVAP canister purge vol-
ume control solenoid valve will then be opened to depressurize the EVAP purge line using intake manifold
vacuum. After this occurs, the EVAP canister purge volume control solenoid valve will be closed.
CAUTION:
• Use only a genuine NISSAN fuel filler cap as a replacemen t. If an incorrect fuel filler cap is used, the
MIL may come on.
• If the fuel filler cap is not tigh tened properly, the MIL may come on.
• Use only a genuine NISSAN rubber tube as a replacement.
DTC Confirmation ProcedureINFOID:0000000005149239
NOTE:
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0442
0442 EVAP control system
small leak detected
(negative pressure) EVAP control system has a leak, EVAP
control system does not operate prop-
erly. • Incorrect fuel tank vacuum relief valve
• Incorrect fuel filler cap used
• Fuel filler cap remains open or fails to close.
• Foreign matter caught in fuel filler cap.
• Leak is in line between intake manifold and EVAP
canister purge volume control solenoid valve.
• Foreign matter caught in EVAP canister vent con- trol valve.
• EVAP canister or fuel tank leaks
• EVAP purge line (pipe and rubber tube) leaks
• EVAP purge line rubber tube bent
• Loose or disconnected rubber tube
• EVAP canister vent control valve and the circuit
• EVAP canister purge volume control solenoid valve and the circuit
• Fuel tank temperature sensor
• O-ring of EVAP canister vent control valve is missing or damaged
• EVAP canister is saturated with water
• EVAP control system pressure sensor
• Fuel level sensor and the circuit
• Refueling EVAP vapor cut valve
• ORVR system leaks
PBIB1026E
Revision: April 20092010 QX56
Page 1572 of 4210
![INFINITI QX56 2010 Factory Service Manual P0442 EVAP CONTROL SYSTEMEC-219
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
• If DTC Confirmation Procedure has been previously conducted, always perform the following procedure INFINITI QX56 2010 Factory Service Manual P0442 EVAP CONTROL SYSTEMEC-219
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
• If DTC Confirmation Procedure has been previously conducted, always perform the following procedure](/img/42/57032/w960_57032-1571.png)
P0442 EVAP CONTROL SYSTEMEC-219
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
• If DTC Confirmation Procedure has been previously conducted, always perform the following procedure
before conducting the next step.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
• Perform “DTC WORK SUPPORT” when the fuel level is between 1/4 and 3/4 full, and vehicle is placed
on flat level surface.
• Always perform test at a temperature of 0 to 30 °C (32 to 86 °F).
WITH CONSULT-III
1. Turn ignition switch ON.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT-III.
4. Make sure that the following conditions are met.
COOLAN TEMP/S: 0 - 70 °C (32 - 158° F)
INT/A TEMP SE: 0 - 30 °C (32 - 86° F)
5. Select “EVP SML LEAK P0442/P1442” of “EVAPO RATIVE SYSTEM” in “DTC WORK SUPPORT” mode
with CONSULT-III.
Follow the instruction displayed.
NOTE:
If the engine speed cannot be maintained within the range displayed on the CONSULT-III screen, go to
EC-13, "
Basic Inspection".
6. Make sure that “OK” is displayed. If “NG” is displayed, refer to EC-219, "
Diagnosis Procedure".
NOTE:
Make sure that EVAP hoses are connected to EVAP canister purge volume control solenoid valve
properly.
WITH GST
NOTE:
Be sure to read the explanation of EC-459, "
DTC Index" before driving vehicle.
1. Start engine.
2. Drive vehicle according to EC-459, "
DTC Index".
3. Stop vehicle.
4. Turn ignition switch OFF, wait at least 10 seconds and then turn ON.
5. Select Service $07 with GST.
- If P0442 is displayed on the screen, go to EC-219, "
Diagnosis Procedure".
- If P0441 is displayed on the screen, go to EC-214, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000005149240
1.CHECK FUEL FILLER CAP DESIGN
1. Turn ignition switch OFF.
2. Check for genuine NISSAN fuel filler cap design.
OK or NG
OK >> GO TO 2.
NG >> Replace with genuine NISSAN fuel filler cap.
2.CHECK FUEL FILLER CAP INSTALLATION
Check that the cap is tightened properly by rotating the cap clockwise.
SEF915U
Revision: April 20092010 QX56
Page 1575 of 4210
![INFINITI QX56 2010 Factory Service Manual EC-222
< COMPONENT DIAGNOSIS >[VK56DE]
P0442 EVAP CONTROL SYSTEM
2. Does water drain from the EVAP canister?
Ye s o r N o
Yes >> GO TO 10.
No (With CONSULT-III)>>GO TO 12.
No (Without CONSULT-III)>> INFINITI QX56 2010 Factory Service Manual EC-222
< COMPONENT DIAGNOSIS >[VK56DE]
P0442 EVAP CONTROL SYSTEM
2. Does water drain from the EVAP canister?
Ye s o r N o
Yes >> GO TO 10.
No (With CONSULT-III)>>GO TO 12.
No (Without CONSULT-III)>>](/img/42/57032/w960_57032-1574.png)
EC-222
< COMPONENT DIAGNOSIS >[VK56DE]
P0442 EVAP CONTROL SYSTEM
2. Does water drain from the EVAP canister?
Ye s o r N o
Yes >> GO TO 10.
No (With CONSULT-III)>>GO TO 12.
No (Without CONSULT-III)>>GO TO 13.
10.CHECK EVAP CANISTER
Weigh the EVAP canister with the EVAP canister vent control valve and EVAP control system pressure sensor
attached.
The weight should be less than 3.2 kg (7.1 lb).
OK or NG
OK (With CONSULT-III)>>GO TO 12.
OK (Without CONSULT-III)>>GO TO 13.
NG >> GO TO 11.
11 .DETECT MALFUNCTIONING PART
Check the following.
• EVAP canister for damage
• EVAP hose between EVAP canister and vehicle frame for clogging or poor connection
>> Repair hose or replace EVAP canister.
12.CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
With CONSULT-III
1. Disconnect vacuum hose to EVAP canister purge volume control solenoid valve at EVAP service port.
2. Start engine.
3. Perform “PURG VOL CONT/V ” in “ACTIVE TEST” mode.
4. Touch “Qu” on CONSULT-III screen to increase “PURG VOL CONT/V” opening to 100%.
5. Check vacuum hose for vacuum when revving engine up to 2,000 rpm.
OK or NG
OK >> GO TO 15.
NG >> GO TO 14.
13.CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
Without CONSULT-III
1. Start engine and warm it up to normal operating temperature.
2. Stop engine.
3. Disconnect vacuum hose to EVAP canister purge volume control solenoid valve at EVAP service port.
4. Start engine and let it idle for at least 80 seconds.
5. Check vacuum hose for vacuum when revving engine up to 2,000 rpm.
OK or NG
OK >> GO TO 16.
NG >> GO TO 14.
14.CHECK VACUUM HOSE
Check vacuum hoses for clogging or disconnection. Refer to EC-37, "
Description".
OK or NG
BBIA0351E
Vacuum should exist.
Vacuum should exist.
Revision: April 20092010 QX56
Page 1578 of 4210
![INFINITI QX56 2010 Factory Service Manual P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-225
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0443 EVAP CANISTER PURGE VOLU
ME CONTROL SOLENOID VALVE
DescriptionINFO INFINITI QX56 2010 Factory Service Manual P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-225
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0443 EVAP CANISTER PURGE VOLU
ME CONTROL SOLENOID VALVE
DescriptionINFO](/img/42/57032/w960_57032-1577.png)
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-225
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0443 EVAP CANISTER PURGE VOLU
ME CONTROL SOLENOID VALVE
DescriptionINFOID:0000000005149242
SYSTEM DESCRIPTION
*1: ECM determines the start signal status by the signals of engine speed and battery voltage.
*2: This signal is sent to the ECM through CAN communication line.
This system controls flow rate of fuel vapor from the EVAP canister. The opening of the vapor by-pass pas-
sage in the EVAP canister purge volume control solenoi d valve changes to control the flow rate. The EVAP
canister purge volume control solenoid valve repeats ON/OFF operation according to the signal sent from the
ECM. The opening of the valve varies for optimum engi ne control. The optimum value stored in the ECM is
determined by considering various engine conditions. When t he engine is operating, the flow rate of fuel vapor
from the EVAP canister is regulated as the air flow changes.
COMPONENT DESCRIPTION
The EVAP canister purge volume control solenoid valve uses a ON/
OFF duty to control the flow rate of fuel vapor from the EVAP canis-
ter. The EVAP canister purge volume control solenoid valve is
moved by ON/OFF pulses from the ECM. The longer the ON pulse,
the greater the amount of fuel vapor that will flow through the valve.
On Board Diagnosis LogicINFOID:0000000005167699
Sensor Input signal to ECMECM functionActuator
Crankshaft position sensor (POS)
Camshaft position sensor (PHASE) Engine speed*
1
EVAP canister
purge flow controlEVAP canister purge vol-
ume control solenoid valve
Mass air flow sensor Amount of intake air
Engine coolant temperature sensor
Engine coolant temperature
Battery Battery voltage*
1
Throttle position sensor Throttle position
Accelerator pedal position sensor Accelerator pedal position
Air fuel ratio (A/F) sensor 1 Density of oxygen in exhaust gas
(Mixture ratio feedback signal)
Fuel tank temperature sensor Fuel temperature in fuel tank
Wheel sensor Vehicle speed*
2
PBIB2057E
DTC No.Trouble diagnosis
name DTC detecting condition
Possible cause
P0443
0443 EVAP canister purge
volume control sole-
noid valve A)
The canister purge flow is detected during the
vehicle is stopped while the the engine is run-
ning, even when EVAP canister purge volume
control solenoid valve is completely closed. • EVAP control system pressure sensor
• EVAP canister purge volume control so-
lenoid valve
(The valve is stuck open.)
• EVAP canister vent control valve
• EVAP canister
• Hoses (Hoses are connected incorrectly or
clogged.)
B)
The canister purge flow is detected during the
specified driving conditions, even when EVAP
canister purge volume control solenoid valve
is completely closed.
Revision: April 20092010 QX56
Page 1579 of 4210
![INFINITI QX56 2010 Factory Service Manual EC-226
< COMPONENT DIAGNOSIS >[VK56DE]
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
DTC Confirmation Procedure
INFOID:0000000005167700
Perform PROCEDURE FOR MALFUNCTION A first.
If the DTC INFINITI QX56 2010 Factory Service Manual EC-226
< COMPONENT DIAGNOSIS >[VK56DE]
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
DTC Confirmation Procedure
INFOID:0000000005167700
Perform PROCEDURE FOR MALFUNCTION A first.
If the DTC](/img/42/57032/w960_57032-1578.png)
EC-226
< COMPONENT DIAGNOSIS >[VK56DE]
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
DTC Confirmation Procedure
INFOID:0000000005167700
Perform PROCEDURE FOR MALFUNCTION A first.
If the DTC cannot be confirmed, perform PROCEDURE FOR MALFUNCTION B.
NOTE:
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure
before conducting the next step.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
PROCEDURE FOR MALFUNCTION A
TESTING CONDITION:
• Perform “DTC CONFIRMATION PROCEDURE” when the fuel level is between 1/4 and 3/4 full, and
vehicle is placed on flat level surface.
• Always perform test at a temperature of 5 to 60 °C (41° F).
• Cool the vehicle so that engine coolant temperature becomes same level as ambient temperature.
With CONSULT-III
1. Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT-III.
2. Check that the following condition are met.
FUEL T/TMP SE: 0 – 35 °C (32 – 95° F)
3. Start engine and wait at least 60 seconds.
4. Check 1st trip DTC.
5. If 1st trip DTC is detected, go to EC-227, "
Diagnosis Procedure".
With GST
1. Turn ignition switch ON.
2. Set voltmeter probes to ECM terminal 107 (FTT sensor signal)
and ground.
3. Check that the voltage is 3.1 – 4.2 V.
4. Start engine and wait at least 60 seconds.
5. Check 1st trip DTC.
6. If 1st trip DTC is detected, go to EC-227, "
Diagnosis Procedure".
PROCEDURE FOR MALFUNCTION B
NOTE:
If DTC Confirmation Procedure has been previously conducted, always perform the following before conduct-
ing the next step.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Always perform test at a temperature of 5 °C (41 °F) or more.
With CONSULT-III
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Turn ignition switch OFF and wait at least 10 seconds.
5. Turn ignition switch ON.
6. Select “PURG VOL CN/V P1444” of “EVAPORATIVE SYSTEM” in “DTC WORK SUPPORT” mode with
CONSULT-III.
7. Touch “START”.
JMBIA2925ZZ
Revision: April 20092010 QX56