INFINITI QX60 HYBRID 2015  First Responder´s 2-6 High Voltage Circuit Shut-Off System 
This vehicle is equipped with a system to shut off the current from the high voltage battery by the following methods:
Service plug Positioned in the right re

Page 21 of 42

INFINITI QX60 HYBRID 2015  First Responder´s Powering Down the High Voltage System 
The high voltage system can be shut down with any 1 of the following procedures:• Turn OFF the power switch and disconnect the 12-volt battery. Refer to
Primar

Page 25 of 42

INFINITI QX60 HYBRID 2015  First Responder´s Alternate Procedure 2 (Remove Service Plug)
DANGER
•Do not remove the service plug without always wearing appropriate Personal
Protective Equipment (PPE) to help protect the responder from serious i

Page 29 of 42

INFINITI QX60 HYBRID 2015  First Responder´s 12. Disconnect negative (-) battery cable and cover it withinsulated tape.
13. Perform the first response action.
3-3.2 Water Submersion
DANGER
Damage level of submerged vehicle may not be apparent. H

Page 30 of 42

INFINITI QX60 HYBRID 2015  First Responder´s 3-3.3 Vehicle Fire
• Always utilize full Personal Protective Equipment (PPE) and self-contained breathingapparatus during fire fighting operations. Smoke from a QX60 HYBRID vehicle fire is 
similar