width JAGUAR XJ6 1994 2.G Electrical Diagnostic Manual
[x] Cancel search | Manufacturer: JAGUAR, Model Year: 1994, Model line: XJ6, Model: JAGUAR XJ6 1994 2.GPages: 327, PDF Size: 13.73 MB
Page 24 of 327
Automatic Transmission (AJ16)
TP ELECTRICAL SIGNAL SYSTEM - P 1791
If the throttle angle signal line is held permanently high or low for more than looms, then this fault will be recognised
and stored. The TCM will adopt the substitute throttle value and turn on the warning lamp. The fault code will only be
stored if the engine speed is greater than 400rpm.
TCM PI HARNESS ECM
CC007/047 P1063/00 1 PI 1041032
Possible causes:
Faulty harness wiring I connection.
. Faulty ECM signal.
Effects:
Transmission warning lamp illuminated.
. MIL illuminated.
Normal mode only available.
Substitute throttle angle adopted.
No kickdown facility.
Remedy:
Repair or renew harness 1 connector.
Examine ECM fault diagnosis (refer to EDM, Section 5.1).
TP SIGNAL SYSTEM RANGE/ PERFORMANCE - P 1790
The throttle signal is a pulse width modulated (pwm) input which runs at a constant frequency of 183 Hz the information is contained in the duty cycle of the signal. If this information is out of range, that is, the duty cycle is less than 5% or
greater than 94%, then the TCM will use a substitute throttle value of 47% and will light the warning lamp and this fault code will be stored. During cranking, this signal is used to convey the engine coolant temperature. The coolant tem- perature signal persistsfor 500 msec after reaching the engine run threshold of 400 rpm. If theTCM does not recognise a valid throttle angle signal afterthis time then a substitute throttle value (47%) will be used and the warning lamp will
be
lit and this fault code will be stored. A fault code will only be stored if the engine speed is greater than 400 rpm. If an out of range coolant temperature is received then a substitute coolant temperature value (77" C) is used but no fault is stored.
X300 EDM 21 Issue 1 August 1994
Page 36 of 327
Automatic Transmission (V12) Powertrain
8.2.3 OPERATING PRlNClPL ES
The electronic control system is split into four main functional areas:
0 Shift Point Control
0 Lock-up Control
0 Pressure Modulation
0 Engine Torque Control
0
Shift Point Control
The optimum gear ratio is selected as a function of transmission output speed, engine load, position of selector switch
and program switch.
Lock-up Control
The torque converter clutch is engaged as a function of load, output speed, gear selected and drive program. Lock-up
is possible in second, third and fourth gear. Apply and release quality is controlled by the pulse width modulated pres-
sure regulator solenoid.
Pressure Modulation
Hydraulic pressure in the transmission shift friction elements is accurately matched to transmission output torque
using an electrically operated solenoid valve to control pressure level. Transmission input torque is calculated from
an output torque value, supplied by EMS, and converter slip.
Engine Torque Control
Engine torque control reduces the energy dissipated within the system during gear shifts. The effect of this control
increase the transmission service life by reducing slippage time, increases comfort by reducing clutch torque trans- mission and allows a greater transfer of power by the transmission unit.
8.2.4 INPUTS / OUTPUTS
8.2.4.1 INPUTS
Transmission Range
The transmission range is detectec ,ythe pressureswitch manifold located within the transmission unit. The manifold
transmits a coded message to the TCM indicating gear selector position.
Performance Mode Select
Performance mode select uses a two wire input to the TCM allowing selection of different transmission operating
modes.
Line A; Used for selection of traction control shift pattern and controlled
by the ABS /TC CM.
Line
B; Used for selection of 'Normal' or 'Sports' mode, manually selected at a two position rocker switch mounted
on the gear selector unit. Switch resistance is equal to or greaterthan look$, open circuit and equal to or less than 0.5$ closed circuit, measured across contacts at a current of 10mA.
Kickdown Switch
This signal is controlled by the operation ofthe kickdown switch on depression of the accelerator pedal to its full extent.
The switch remains in 'normally open' position until contact with the pedal closes the contacts. Switch resistance is
equal to or greater than look$, open circuit, and equal to or less than 0.5$ closed circuit, measured across contacts at
a current of
10Ma.
Calibration Select
The calibration select input allows identification of different vehicle specifications, ie 4.0 liter supercharged, or 6.0 liter (V12). The link, to ground, from the TCM is either short or open circuit, dependant upon internal software calibration
for each vehicle variant.
X300 EDM 5 Issue 1 August 1994
Page 83 of 327
Climate Control Systems
Climate Control Module Connections, continued
35 (16-way) Input Solar sensor
36 (16
-way) Input Centre vent servo motor feedback po- tentiometer
37
(16-way) Input RH air intake servo motor feedback po- tentiometer F / R
38 (16-way) Not used
39 (16
-way) Input Cool air bypass servo motor feedback
potentiometer
I 40(16-way) llnput I Coolant temperature signal
1 41 (16-way) llnput I RH blower motor voltage feedback
I 42 (16-way) I Output I RH blower motor drive signal
I 43(16-way) I Input
I Differential potentiometer
44 (16
-way) Input Defrost servo motor feedback poten-
tiometer
45
(%-way) Input LH air intake servo motor feedback po- tentiometer - F / R
46 (16-way) Not used
47 (16
-way) Input Foot servo motor feedback potentiome-
ter
48 (16
-way) Not used
49 (16
-way) Input LH blower motor voltage feedback
50 (16
-way) Output LH blower motor drive signal
51 (26
-way) Input Compressor ON signal
52 (26
-way) Output Water valve
53 (26
-way) Output RH Blower motor relay
54 (26
-way) Output Heated front screen relays
55 (26
-way) Output Heated Door Mirror relay
Specification
Open collector R = 578, connected to
IGN, activated low
Open collector
R = IKn, connected to
IG N, activated high
Open collector R = IKQ, connected to
IGN, activated high
Voltage /temperature values
Voltage
/ temperature values
Open collector
R = IKQ, connected to
IGN, activated high
AJ16
- Ground (lock sensor not fitted)
VI2 - Ign. voltage (lock sensor fitted)
Voltage
/ temperature values
Voltage
/ temperature values
Voltage
/ temperature values
Resistance 6W.
&IO%
0% closed - IV, 100% open - 4V
Resistance 6Kn
+IO%.
0% closed - IV, IOW0 open - 4V
Pulse
width modulated signal I
OV to 3V max. I
Resistance IOW. &IO%.
Min. IV, Max. 4V
Resistance
6W. +IO%.
0% closed - IV, IOW0 open - 4V
Resistance 6W.
+IO%.
Resistance 6W. &IO%.
0% closed - IV, 10096 open - 4V
I
Battery voltage when compressor ON
1 amp at 12 volts
Load
36Q at 12V IGN, activated low
0
0
0
0
Issue 1 August 1994 8 X300 EDM