oxygen sensor LEXUS SC400 1991 Service User Guide

LEXUS SC400 1991 Service User Guide SC400 1991 LEXUS LEXUS https://www.carmanualsonline.info/img/36/57051/w960_57051-0.png LEXUS SC400 1991 Service User Guide

Page 1486 of 4087

LEXUS SC400 1991  Service User Guide 
(b)  Install the exhaust manifold with 8 new nuts. Uniformlytighten  the nuts in several passes.
Torque: 44 N Vm (450 kgf Vcm, 33 ft Vlbf)
(c)  Install the main heated oxygen sensor.
Torque: 44 N Vm

Page 1488 of 4087

LEXUS SC400 1991  Service User Guide 
(e)  Retighten  the cylinder head bolts 90 in the numerical order
shown.
(f)  Check that the painted mark is now at a 90  angle to front.
4.  CONNECT MAIN HEATED OXYGEN SENSOR CONNECTORS
Connect  t

Page 1523 of 4087

LEXUS SC400 1991  Service User Guide 
(i)  Remove the bolt holding the engine wire clamp to the heaterwater valve bracket.
(j)  Remove the 2 bolts holding the engine wire clamp to the
body.
(k)  Pull out the engine wire from the cabin.
N

Page 1570 of 4087

LEXUS SC400 1991  Service User Guide 
7. INSTALL TAILPIPE
(a)  Install the hook of the tailpipe to the ring on the tailpipebracket.
(b)  Install a new gasket and tailpipe to the center exhaust pipe with 2 bolts. Install the 2 tailpipes.

Page 1591 of 4087

LEXUS SC400 1991  Service User Guide 
(i)  Remove the bolt holding the engine wire clamp to theheater water valve bracket.
(j)  Remove the two bolts holding the engine wire clamp to the body.
(k)  Pull out the engine wire from the cabin.

Page 1634 of 4087

LEXUS SC400 1991  Service User Guide 
9.  INSTALL CATALYTIC CONVERTERS (MAIN)Install a new gasket and the catalytic converter with three
new nuts. Install the two catalytic converters.
Torque: 62 N Vm (630 kgf Vcm, 46 ft Vlbf)
10.  INSTA

Page 1688 of 4087

LEXUS SC400 1991  Service User Guide 
Troubleshooting
If the CO/HC readings do not comply with regulations, pre-
form troubleshooting in the order given below.
(a)  Check oxygen sensor operation.(See page FI±73)
(b) See  the table below

Page 1702 of 4087

LEXUS SC400 1991  Service User Guide 
Troubleshooting
If the HC/CO concentration does not comply with regulations,
perform troubleshooting in the order given below.
(a)  Check oxygen sensor operation.(See page  FI±113)
(b) See  the tabl

Page 1733 of 4087

LEXUS SC400 1991  Service User Guide 
REMOVAL OF CYLINDER HEAD
(See Components on pages EM±34 and 35)1.  DISCONNECT HIGH±TENSION CORDS FROM SPARK PLUGS
(See steps 1 to 8 on pages EM±10 and 11)
2. REMOVE SPARK PLUGS (See step 2 on page

Page 1758 of 4087

LEXUS SC400 1991  Service User Guide 
16.  INSTALL EXHAUST MANIFOLD(a)  Install a new gasket and the exhaust manifold with thefour nuts. Install the No. 1 and No. 2 exhaust manifolds.
Torque: 39 N Vm (400 kgf Vcm, 29 ft Vlbf)
(b)  Instal