sensor MERCEDES-BENZ ML320 1997 Complete Repair Manual
[x] Cancel search | Manufacturer: MERCEDES-BENZ, Model Year: 1997, Model line: ML320, Model: MERCEDES-BENZ ML320 1997Pages: 4133, PDF Size: 88.89 MB
Page 3332 of 4133

REAR VENTILATION CO NTROL PANEL, FUNCTION - GF83.40-P-2007GI
MODEL 163 as of 1.9.01 with CODE (580a) Automatic air conditioning
N72/2s3 Rear ventilation control panel
Auto button
Air distribution button
Blower button
Auxiliary fan, location/purpose/function
with code 580 up to 31.08.01
Engine 112.942, 112.970 with
code 580a as of 01.09.01GF83.40-P-
2162GH
Engine and AC electric su ction fan with integrated
control, location/purpose/function
Engine 113.942 with code 580a up
to 31.08.01
Engine 113.981, 113.965, 612.963,
628.963 with code 580a as of
01.09.01
GF83.40-P-
2172GI
Condenser, location/purpose/function GF83.40-P-
2152GC
Evaporator location/purpose/design/function GF83.40-P-
2121GC
Fluid reservoir, location/purpose/function GF83.40-P-
2153GI
Expansion valve, locati on/purpose/design/ function GF83.40-P-
2123GC
Refrigerant pressure and temperature sensor,
location/purpose/function GF83.40-P-
2171GI
Refrigerant compressor, location/purpose/
design/function GF83.55-P-
2100P
Control valve, location/purpose/function GF83.55-P-
2102P
Belt pulley, location/ purpose/design/function GF83.55-P-
2103P
Pressure relief valve, location/purpose/function GF83.55-P-
2104P
2001 Mercedes-Benz ML320
1998-2005 HVAC Climate Control - 163 Chassis
me
Saturday, October 02, 2010 3:23:16 PMPage 88 © 2006 Mitchell Repair Information Company, LLC.
Page 3341 of 4133

REST BUTTON, FUNCTION - GF83.40-P-2109-01GI
Function
Pressing the reset button ( ) on the AAC push-button control module (N22) switches on the residual engine
heat utilization system. When the engine is switched off, the residual heat heats the vehicle depending on the
temperature setting on the AAC push-button control panel (N22) and the ambient temperature in the vehicle
interior. The vehicle can be heated for approx. 30 min, with the engine switched off. The function is only
available with the ignition switched off or in position 1. If there is low voltage, the residual heat function is
automatically switched off.
The flaps are in automatic mode and the quantity of air is also automatically regulated.
The residual heat function is switched off,
if the electronic key is moved to position 2 in the starter switch,
after approx. 30 minutes,
if the battery voltage drops below 11V.
AUXILIARY FAN, FUNCTION - GF83.40-P-2115-01GH
Function
Depending on the refrigerant pressure and/or the coolant temperature the left auxiliary fan (M4m1), right
auxiliary fan (M4m2) are actuated.
The all-activity module (AAM) (N10) receives the coolant temperature from the coolant temperature sensor and
the refrigerant pressure from the refrigerant pressure sensor (B12).
The all-activity module (AAM) (N10) compares this input information with stored values and actuates the left
auxiliary fan (M4m1), right auxiliary fan (M4m2).
When the following values are indicated the left auxiliary fan (M4m1), right auxiliary fan (M4m2) are switched
on or off:
refrigerant pressure >16 bar = auxiliary fan ON
refrigerant pressure < 12 bar = auxiliary fan OFF
coolant temperature > 105°C = auxiliary fan ON
coolant temperature < 94°C = auxiliary fan OFF
AUXILIARY FAN, FUNCTION - GF83.40-P-2115-01GI
Function
Depending on the refrigerant pressure and/or the coolant temperature the left auxiliary fan (M4m1) and the right
auxiliary fan (M4m2) are actuated.
2001 Mercedes-Benz ML320
1998-2005 HVAC Climate Control - 163 Chassis
me
Saturday, October 02, 2010 3:23:16 PMPage 97 © 2006 Mitchell Repair Information Company, LLC.
Page 3342 of 4133

The all-activity module (AAM) (N10) receives the coolant temperature by the coolant temperature sensor
(B11/4) and the refrigerant pressure by the refrigerant pressure and temperature sensor (B12/2). The all-activity
module (AAM) (N10) compares this input information with stored values and actuates the left auxiliary fan
(M4m1) and the right auxiliary fan (M4m2).
When the following values are indicated the left auxiliary fan (M4m1), right auxiliary fan (M4m2) are switched
on or off:
refrigerant pressure >16 bar = auxiliary fan ON
refrigerant pressure <13 bar = auxiliary fan OFF
coolant temperature > 105°C = auxiliary fan ON
coolant temperature < 97°C = auxiliary fan OFF
AUXILIARY FAN, LOCATION - GF83.40-P-2115-02GH
The auxiliary fans are located (M4) directly in front of the condenser.
Fig. 79: Identifying Left Auxiliary Fan And Right Additional Fan
ENGINE/AIR CONDITIONING ELECTRIC FAN, FUNCTION - GF83.40-P-2118-01GH
Function
Depending on the refrigerant pressure and/or the coolant temperature the fan speed is increased infinitely.
Engines 612.963 and 628.963
The CDI control module (N3/9) receives the coolant temperature from the coolant temperature sensor and via
the all-activity module (AAM) (N10) via the CAN bus the refrigerant pressure from the refrigerant pressure
sensor (B12).
2001 Mercedes-Benz ML320
1998-2005 HVAC Climate Control - 163 Chassis
me
Saturday, October 02, 2010 3:23:16 PMPage 98 © 2006 Mitchell Repair Information Company, LLC.
Page 3343 of 4133

This input information is relayed by the CDI control module (N3/9) to the integrated control module of the
electric engine/AC intake fan with integrated control (M4/7).
Engines 113.942 and 113.981
The all-activity module (AAM) (N10) receives the coolant temperature via the coolant temperature sensor and
the refrigerant pressure via the refrigerant pressure sensor (B12).
This input information is relayed by the all-activity module (AAM) (N10) to the integrated control module of
the engine and AC electric suction fan with integrated control (M4/7)
There the input information is compared with the stored values and, if necessary, the speed of the engine and
AC electric suction fan with integrated control (M4/7) is increased to 100 %.
The engine and AC electric suction fan with integrated control (M4/7) operates with AC switched on and in the
reheat mode for basic ventilation with a capacity of up to 20 %.
The basic ventilation can be switched off under the following conditions:
At an outdoor temperature of < or = 15°C the value of the outdoor temperature is transmitted from the
outside temperature sensor (B10/5) to the AC control module (N19).
The pressure-dependent fan speed remains the same.
At a vehicle speed of > 75 km/h
The vehicle speed value comes from the traction system control module via the instrument cluster (A1)
and CDI control module (N3/9), to the control module integrated in the electric suction fan engine and
AC with integrated control (M4/7). The pressure-dependent fan speed remains the same.
An overrun time of 60 s can be set in order to ensure that the engine and AC electric suction fan with integrated
control (M4/7) will continue to operate even where the refrigerant compressor is temporarily switched off by
the icing protection.
The engine and AC electric suction fan with integrated control (M4/7) has a power rating of 550W.
ELECTRIC FAN, ENGINE/AIR CONDITIONING, LOCATION - GF83.40-P-2118-02GH
The engine and AC electric suction fan with integrated control (M4/7) is located immediately in front of the
condenser.
2001 Mercedes-Benz ML320
1998-2005 HVAC Climate Control - 163 Chassis
me
Saturday, October 02, 2010 3:23:16 PMPage 99 © 2006 Mitchell Repair Information Company, LLC.
Page 3349 of 4133

Fig. 85: Identifying Expansion Valve Design
REFRIGERANT PRESSURE SENSOR, FUNCTION - GF83.40-P-2126-01GH
Function
Shutting off the refrigerant compressor
The refrigerant pressure sensor (B12) sends the current value to the All Activity Module (N10). The All
Activity Module (N10) compares this input information with stored values and actuates the refrigerant
compressor.
At the following values, the refrigerant compressor is switched on or off:
refrigerant pressure > 3 bar = refrigerant compressor ON
refrigerant pressure < 2 bar = refrigerant compressor OFF
refrigerant pressure < 26 bar = refrigerant compressor ON
refrigerant pressure > 30 bar = refrigerant compressor OFF
Cut-in of the auxiliary fan (engines 111.977 and 112.942)
The pressure value received from the refrigerant pressure sensor (B12) is recorded by the All Activity Module
(N10) and compared there with a stored value.
As of 12/99, the Extended Activity Module (EAM, N10/1) assumes this task from the All Activity Module
(N10).
At the following values, the auxiliary fan (M4m1, M4m2) is switched on or off:
refrigerant pressure > 16 bar = auxiliary fan ON
refrigerant pressure <12 bar = auxiliary fan OFF
Cut-in of the electric fan for engine/AC (engines 113.942/981 and 612.963)
The pressure value received from the refrigerant pressure sensor (B12) is recorded by the All Activity Module
(N10), sent to the control module inte
grated in the electric fan for engine/AC and compared there with a stored
Expansion valve,
locationModel 168GF83.40-P-2123-
02GC
Model 163GF83.40-P-2123-
02GH
Expansion valve, taskThe expansion valve injects the liquid refrigerant into the
evaporator.
Expansion valve,
function GF83.40-P-2123-
01GC
2001 Mercedes-Benz ML320
1998-2005 HVAC Climate Control - 163 Chassis
me
Saturday, October 02, 2010 3:23:16 PMPage 105 © 2006 Mitchell Repair Information Company, LLC.
Page 3350 of 4133

value.
At the following values the electric fan for engine/AC (M4/7) is switched on or off:
refrigerant pressure > 20 bar = electric fan for engine/AC ON
refrigerant pressure <12 bar = electric fan for engine/AC OFF
REFRIGERANT PRESSURE SENSOR, LOCATION - GF83.40-P-2126-02GH
The refrigerant pressure sensor (B12) is located at the front left in the engine compartment at the high-pressure
line (8) between the refrigerant compressor (A9) and the capacitor (7).
Fig. 86: Identifying Refrigerant Pressure Sensor
DEFROSTER BUTTON, FUNCTION - GF83.40-P-2139-02GI
Function
Pressing the defroster button ( ) initiates the defrost function.
Function feedback takes place by means of a yellow LED.
The defrost function works according to the following logic:
the heating power is regulated using the outside temperature
the entire air flow is directed at the windshield and the front side windows, and the defroster nozzles are
2001 Mercedes-Benz ML320
1998-2005 HVAC Climate Control - 163 Chassis
me
Saturday, October 02, 2010 3:23:16 PMPage 106 © 2006 Mitchell Repair Information Company, LLC.
Page 3356 of 4133

REFRIGERANT PRESSURE SENSOR, LOCATION/TASK/FUNCTION - GF83.40-P-2156GH
MODEL 163 up to 31.08.01 with CODE (580) Air conditioning or Tempmatic for USA
AIR DISTRIBUTION BUTTON, LOCATION/TASK/FUNCTION - GF83.40-P-2159GI
MODEL 163 as of 01.09 01 with CODE (580a) Automatic air conditioning in the rear ventilation control
panel
Fig. 94: Identifying Air Distribution Button
AUXILIARY FAN, LOCATION/PURPOSE/FUNCTION - GF83.40-P-2162GH
MODEL 163 up to 31.8.01 with ENGINE 111.977,112.942 /970 with CODE (580) Air conditioning or
Tempmatic for USA
Draining the refrigerant
Receiver, function GF83.40-P-2122-
01GI
Refrigerant pressure
sensor, location GF83.40-P-
2126-02GH
Refrigerant pressure
sensor, taskThe refrigerant pressure sensor (B12) detects the refrigerant
pressure and sends it to the All Activity Module.
Refrigerant pressure
sensor, function GF83.40-P-
2126-01GH
Air distribution
button, locationThe air distribution button ( ) is located in the center in
the rear ventilation control panel (N72/2s3).
Air distribution
button, taskThe air distribution button ( ) controls the air
distribution to the rear area nozzle and the rear legroom air outlets
for ventilating the rear area.
Air distribution push-
button function GF83.40-P-
2101-01GI
2001 Mercedes-Benz ML320
1998-2005 HVAC Climate Control - 163 Chassis
me
Saturday, October 02, 2010 3:23:16 PMPage 112 © 2006 Mitchell Repair Information Company, LLC.
Page 3357 of 4133

MODEL 163 as of 1.9.01 with ENGINE 112.942 /970 with CODE (580a) Automatic air conditioning
REFRIGERANT PRESSURE AND TEMPERATURE SENSOR, FUNCTION - GF83.40-P-2171-01GI
Detecting the refrigerant pressure
The refrigerant pressure and temperature sensor (B12/2) detects the refrigerant pressure and sends the
determined value via the CAN-BUS to the AAC push-button control module (N22). This value is compared
with a stored temperature/pressure curve.
The refrigerant pressure and temperature sensor (B12/2) operates in a pressure value range of from 0 to 35 bar.
Shutting of the refrigerant compressor
At the following values, the refrigerant compressor is switched off.
refrigerant pressure < 1.75 bar = refrigerant compressor OFF
refrigerant pressure > 30 bar = refrigerant compressor OFF
Switching on the refrigerant compressor
The refrigerant compressor is switched on at the following value
refrigerant pressure > 2.25 bar = refrigerant compressor ON
Detecting the refrigerant temperature
The refrigerant pressure and temperature sensor (B12/2) detects the temperature of the refrigerant and sends the
determined value via the CAN-BUS to the AAC push-button control module (N22). This value is compared
with a stored temperature/pressure curve and the refrigerant level is determined as a result.
With a refrigerant level that is too low, the refrigerant compressor is switched off by the AAC push-button
control module (N22) via the CAN-BUS.
The AC OFF mode is activated and can no longer be quit. Only when the error has been eliminated and the
diagnostic trouble code memory in the AAC push-button control module (N22) has been erased will the system
be operational again.
Auxiliary fan,
location GF83.40-P-2115-
02GH
Auxiliary fan,
purposeThe left auxiliary fan (M4m1) and right auxiliary fan (M4m2) serve
for cooling the coolant and the refrigerant.
Auxiliary fan,
functionup to 31.08.01GF83.40-P-2115-
01GH
as of 1.09.01GF83.40-P-2115-
01GI
2001 Mercedes-Benz ML320
1998-2005 HVAC Climate Control - 163 Chassis
me
Saturday, October 02, 2010 3:23:16 PMPage 113 © 2006 Mitchell Repair Information Company, LLC.
Page 3358 of 4133

The refrigerant pressure and temperature sensor (B12/2) operates in a temperature value range of from -10°C to
+90°C.
Cut-in of electric suction-type fan for engine and AC with integrated control (M4/7)
At the following values the electric suction-type fan for engine and AC with integrated control (M4/7) is
actuated:
refrigerant pressure < 14 bar = fan OFF
Refrigerant pressure > 20 bar = fan ON (100 %)
refrigerant pressure 14 to 20 bar = Continuous linear increase in fan speed (20 -100 %)
REFRIGERANT PRESSURE AND TEMPERATURE SENSOR POSITION/TASK/FUNCTION - GF83.40-P-2171GI
MODEL 163 as of 01.09.01 with CODE (580a) Automatic air conditioning
Fig. 95: Identifying Refrigerant Pressure And Temperature Sensor
Refrigerant pressure
and temperature sensor,
locationThe refrigerant pressure sensor (B12/2) is located at the front left
in the engine compartment at the high-pressure line (8) between
the refrigerant compressor (A9) and the capacitor (7).
Refrigerant pressure
and temperature sensor,
taskThe refrigerant pressure and temperature sensor (B12/1) detects
the refrigerant pressure and the refrigerant temperature and sends
these values to the AAC push-button control module (N22).
Refrigerant pressure
2001 Mercedes-Benz ML320
1998-2005 HVAC Climate Control - 163 Chassis
me
Saturday, October 02, 2010 3:23:16 PMPage 114 © 2006 Mitchell Repair Information Company, LLC.
Page 3359 of 4133

ENGINE AND AC ELECTRIC SUCTION FAN WITH INTEGRATED CONTROL, FUNCTION - GF83.40-P-2172-01GI
Function
Depending on the refrigerant pressure and/or on the coolant temperature the speed of the engine and AC electric
suction fan with integrated control (M4/7) is increased infinitely.
The engine and AC electric suction fan with integrated control (M4/7) receives the coolant temperature from the
coolant temperature sensor (B11/4) and the refrigerant pressure from the refrigerant pressure and temperature
sensor (B12/2).
This input information is compared by the engine and AC electric suction fan with integrated control (M4/7)
with the stored values and, if necessary, the speed of the engine and AC electric suction fan is increased to 100
%
The engine and AC electric suction fan with integrated control (M4/7) operates with AC switched on and in the
reheat mode for basic ventilation with a capacity of up to 20 %.
The basic ventilation can be switched off under the following conditions:
At an outside temperature of < or = 15°C.
The pressure-dependent fan speed remains the same.
At a driving speed of > 75 km/h.
The pressure-dependent fan speed remains the same.
An overrun time of 60 s can be set in order to ensure that the engine and AC electric suction fan with integrated
control (M4/7) will continue to operate even where the refrigerant compressor is temporarily switched off by
the icing protection.
The engine and AC electric suction fan with integrated control (M4/7) has a power rating of 850 W.
ELECTRIC SUCTION-TYPE FAN FOR ENGINE AND AC WITH INTEGRATED CONTROL, LOCATION/TASK/FUNCTION
- GF83.40-P-2172GI
MODEL 163 as of 1.9.01 with ENGINE 113.965 /981, 612.963, 628.963 with CODE (580a) Automatic air
conditioning
MODEL 163 as of 1.9.01 up to 31.8.02 with ENGINE 113.942 with CODE (580a) Automatic air
conditioning
and temperature sensor,
function GF83.40-P-
2171-01GI
2001 Mercedes-Benz ML320
1998-2005 HVAC Climate Control - 163 Chassis
me
Saturday, October 02, 2010 3:23:16 PMPage 115 © 2006 Mitchell Repair Information Company, LLC.