turn signal MITSUBISHI 380 2005 Owner's Guide
[x] Cancel search | Manufacturer: MITSUBISHI, Model Year: 2005, Model line: 380, Model: MITSUBISHI 380 2005Pages: 1500, PDF Size: 47.87 MB
Page 144 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-144
INSPECTION PROCEDURE C-5: Central Door Locking System: Forgotten Key Prevention Function 
does not Work Normally.
NOTE: This troubleshooting procedure requires use 
of diagnostic tool MB991958 and SWS monitor kit 
MB991813. For details on how to use the SWS mon-
itor, refer to "How to connect SWS monitor 
P.54B-13."
.
CIRCUIT OPERATION
The ETACS-ECU operates the forgotten key preven-
tion function according to the following switches:
Key reminder switch: OFF
Front door switch: ON
Front door lock actuator switch: being turned on
The ETACS-ECU operates the forgotten key preven-
tion function under the following conditions:
Ignition key: inserted into the ignition key cylinder
Front door: open
Front door lock: being locked
.
TECHNICAL DESCRIPTION (COMMENT)
If the function does not work normally, the input cir-
cuit system from the switches or the ETACS-ECU 
may be defective (refer to "CIRCUIT OPERATION").
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
Trouble in input signal system
The wiring harness or connectors may have 
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The ETACS-ECU may be defective 
Page 146 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-146
STEP 2. Check the input signal by using "DATA LIST" 
menu of the SWS monitor.
Turn the ignition switch to the "ON" position before checking 
input signals from the ignition switch (IG1).
(1) Operate the diagnostic tool MB991958 according to the 
procedure below to display "ETACS ECU."
a. Select "Interactive Diagnosis."
b. Select "System Select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "Data List."
f. Select "ETACS ECU."
(2) Check that normal conditions are displayed for the items 
described in the table below.
Q: Does diagnostic tool MB991958 display "FRONT DOOR 
SW" as normal condition?
YES : Go to Step 3.
NO : Refer to Inspection Procedure M-4 "ETACS-ECU 
does not receive any signal from the front door 
switches P.54B-413." ITEM NO. ITEM NAME NORMAL CONDITION
ITEM 32 FRONT DOOR SW ON 
Page 153 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-153
STEP 2. Check the input signal by using "DATA LIST" 
menu of the SWS monitor.
Turn the ignition switch to the "ON" position before checking 
input signals from the ignition switch (IG1).
(1) Operate the diagnostic tool MB991958 according to the 
procedure below to display "ETACS ECU."
a. Select "Interactive Diagnosis."
b. Select "System Select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "Data List."
f. Select "ETACS ECU."
(2) Check that normal conditions are displayed for the items 
described in the table below.
Q: Does the diagnostic tool MB991958 display "IG SW 
(IG1)" as normal condition?
YES : Go to Step 3.
NO : Refer to Inspection Procedure M-2 "ETACS-ECU 
does not receive any signal from the ignition switch 
(IG1) P.54B-408."
STEP 3. Check power window relay connector C-203 for 
loose, corroded or damaged terminals, or terminals 
pushed back in the connector.
Q: Is power window relay connector C-203 in good 
condition?
YES : Go to Step 4.
NO : Repair or replace the damaged component(s). Refer 
to GROUP 00E, Harness Connector Inspection 
P.00E-2. The power windows function should now 
work normally. ITEM NO. ITEM NAME NORMAL CONDITION
ITEM 30 IG SW (IG1) ON 
Page 163 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-163
STEP 2. Check the input signal by using "DATA LIST" 
menu of the SWS monitor.
Turn the ignition switch to the "ON" position before checking 
input signals from the ignition switch (IG1).
(1) Operate diagnostic tool MB991958 according to the 
procedure below to display "ETACS ECU."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "Data List."
f. Select "ETACS ECU."
(2) Check that normal conditions are displayed for the items 
described in the table below.
Q: Does the diagnostic tool MB991958 display the items 
"IG SW (IG1)", "FRONT DOOR SW" as normal 
condition?
Normal condition displayed for all the items : Replace 
the ETACS-ECU. Verify that the power window timer 
works normally.
Normal condition is not displayed for "IG SW (IG1)" : 
Refer to Inspection Procedure M-2 "ETACS-ECU 
does not receive any signal from the ignition switch 
(IG1) P.54B-408."
Normal condition is not displayed for "FRONT DOOR 
SW" : Refer to Inspection Procedure M-4 "ETACS-ECU 
does not receive any signal from the front door 
switches P.54B-413." ITEM NO. ITEM NAME NORMAL CONDITION
ITEM 30 IG SW (IG1) OFF
ITEM 32 FRONT DOOR SW 
Page 192 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-192
STEP 2. Check the input signal (by using the pulse check 
mode of the monitor).
Check input signals from the transmitter.
To prevent damage to diagnostic tool MB991958, always 
turn the ignition switch to the "LOCK" (OFF) position 
before connecting or disconnecting diagnostic tool 
MB991958.
(1) Connect diagnostic tool MB991958.Refer to "How to 
connect SWS monitor P.54B-13."
(2) Operate diagnostic tool MB991958 according to the 
procedure below to display "Pulse check."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "Pulse Checking."
(3) Push the transmitter "LOCK" or "UNLOCK" button.
(4) Check that diagnostic tool MB991958 sounds
Q: When the transmitter "LOCK" or "UNLOCK" button is 
turned ON, does diagnostic tool MB991958 sound?
YES : Replace the ETACS-ECU. All the doors can be locked 
or unlocked by means of the transmitter.
NO : Refer to Inspection Procedure N-8 "ETACS-ECU 
does not receive any signal from the lock, unlock, 
trunk or panic switch P.54B-472." 
Page 193 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-193
INSPECTION PROCEDURE E-2: Keyless Entry System: The dome lamp, the turn-signal lamps and the 
horn do not operate through the answerback function.
.
CIRCUIT OPERATION
The ETACS-ECU operates the following functions 
when it receives lock or unlock signal from the trans-
mitter:
Dome lamp answerback function
Turn-signal lamp answerback function
Horn answerback function
.
TECHNICAL DESCRIPTION (COMMENT)
The turn-signal lamps and horn answerback func-
tions can be disabled or enabled. However, the dome 
lamp answerback function cannot be disabled.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
The turn-signal lamp may be defective
The dome lamp may be defective
The horn may be defective
The ETACS-ECU may be defective
The wiring harness or connectors may have 
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector 
Page 194 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-194
DIAGNOSIS
Required Special Tools:
MB991223: Harness Set
MB991958: diagnostic tool (MUT-III Sub Assembly)
MB991824: Vehicle Communication Interface (V.C.I.)
MB991827: MUT-III USB Cable
MB991910: MUT-III Main Harness A
STEP 1. Verify the keyless entry system.
Q: Does the keyless entry system work normally?
YES : Go to Step 2.
NO : Refer to Inspection Procedure E-1 "Keyless entry 
system does not operate P.54B-191."
STEP 2. Check the configuration function.
Q: Has the answerback function been enabled by means of 
the adjustment function?
YES : Go to Step 3.
NO : Enable the answerback function by means of the 
adjustment function. Verify that the answerback 
functions work normally.
STEP 3. Verify trouble symptom.
Q: Which answerback function is defective?
Only the dome lamp : Go to Step 4.
Only the turn-signal lamps : Go to Step 5.
Only the horn : Go to Step 6.
Dome lamp, turn-signal lamps and horn : Replace the 
ETACS-ECU. Verify that the answerback functions 
work normally.
STEP 4. Verify the dome lamp.
Q: Does the dome lamp illuminate normally?
YES : Replace the ETACS-ECU. Verify that the answerback 
functions work normally.
NO : Refer to Inspection Procedure K-1 "The dome lamp 
do not illuminate and go out normally P.54B-359."
STEP 5. Verify the hazard warning lamp.
Q: Does the hazard warning lamp work normally?
YES : Replace the ETACS-ECU. Verify that the answerback 
functions work normally.
NO : Refer to Inspection Procedure I-2 "Hazard warning 
lamps do not flash when the hazard warning lamp 
switch is turned on P.54B-314." 
Page 203 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-203
STEP 2. Check the input signal (by using the pulse check 
mode of the monitor).
Check the input signals from the following switches:
Key reminder switch
Hazard warning lamp switch
To prevent damage to diagnostic tool MB991958, always 
turn the ignition switch to the "LOCK" (OFF) position 
before connecting or disconnecting diagnostic tool 
MB991958.
(1) Connect diagnostic tool MB991958.Refer to "How to 
connect SWS monitor P.54B-13."
(2) Operate diagnostic tool MB991958 according to the 
procedure below to display "Pulse check."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "Pulse Checking."
(3) Check the switches (see table below) applicable for the 
input signal check are operated.
(4) Check diagnostic tool MB991958 sounds or not.
Q: When the key reminder switch and the hazard warning 
lamp switch are operated, does diagnostic tool 
MB991958 sound in each case?
Buzzer of diagnostic tool MB991958 sounds normally. : 
Replace the ETACS-ECU. Verify that the encrypted 
code can be registered in the transmitter.
diagnostic tool MB991958 does not sound when the 
ignition key is removed and reinserted : Refer to 
Inspection Procedure N-1 "ETACS-ECU does not 
receive any signal from the key reminder switch 
P.54B-432."
diagnostic tool MB991958 does not sound when the 
hazard warning lamp switch is turned from "OFF" to 
"ON" : Refer to Inspection Procedure N-2 "ETACS-ECU 
does not receive any signal from the hazard warning 
lamp switch P.54B-436." ITEM NAME CHECK CONDITION
Key reminder switch Remove and reinsert the 
ignition key
Hazard warning lamp switch Turn the hazard warning lamp 
switch from "OFF" to "ON" 
position. 
Page 206 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-206
STEP 2. Check the input signal (by using the pulse check 
mode of the monitor).
Check input signals from the transmitter.
To prevent damage to diagnostic tool MB991958, always 
turn the ignition switch to the "LOCK" (OFF) position 
before connecting or disconnecting diagnostic tool 
MB991958.
(1) Connect diagnostic tool MB991958.Refer to "How to 
connect SWS monitor P.54B-13."
(2) Operate diagnostic tool MB991958 according to the 
procedure below to display "Pulse check."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "Pulse Checking."
(3) Push the transmitter "TRUNK" button.
(4) Check that diagnostic tool MB991958 sounds
Q: When the transmitter "TRUNK" button is turned ON, 
does diagnostic tool MB991958 sound?
YES : Go to Step 3.
NO : Refer to Inspection Procedure N-8 "ETACS-ECU 
does not receive any signal from the lock, unlock, 
trunk or panic switch P.54B-472." 
Page 219 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-219
INSPECTION PROCEDURE F-2: Sunroof: Any of the sunroof switch positions is defective.
.
TECHNICAL DESCRIPTION (COMMENT)
The sunroof switch or the sunroof motor assembly 
may be defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
The sunroof switch may be defective
The sunroof motor assembly may be defective
The wiring harness or connectors may have 
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
DIAGNOSIS
Required Special Tools:
MB991223: Harness Set
MB991958: diagnostic tool (MUT-III Sub Assembly)
MB991824: Vehicle Communication Interface (V.C.I.)
MB991827: MUT-III USB Cable
MB991910: MUT-III Main Harness A
Check the input signal (by using the pulse check mode of 
the monitor).
Check the input signals from the sunroof switch.
To prevent damage to diagnostic tool MB991958, always 
turn the ignition switch to the "LOCK" (OFF) position 
before connecting or disconnecting diagnostic tool 
MB991958.
(1) Connect diagnostic tool MB991958.Refer to "How to 
connect SWS monitor P.54B-13."
(2) Operate the diagnostic tool MB991958 according to the 
procedure below to display "Pulse check."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "Pulse Checking."
(3) When each function of the sunroof switch is operated 
(turned on), check that diagnostic tool MB991958 sounds.
Q: Does diagnostic tool MB991958 sound when the 
sunroof switch is operated?
YES : Replace the sunroof motor assembly. Check that the 
sunroof works at all positions normally.
NO : Refer to Inspection Procedure M-8 "ETACS-ECU 
does not receive any signal from the up, open or 
close/down switch P.54B-429."