maintenance NISSAN 350Z 2007 Z33 Automatic Air Conditioner Workshop Manual
[x] Cancel search | Manufacturer: NISSAN, Model Year: 2007, Model line: 350Z, Model: NISSAN 350Z 2007 Z33Pages: 142, PDF Size: 5.44 MB
Page 1 of 142
ATC-1
AUTOMATIC AIR CONDITIONER
J AIR CONDITIONER
CONTENTS
C
D
E
F
G
H
I
K
L
M
SECTION AT C
A
B
AT C
Revision: 2006 November2007 350Z
AUTOMATIC AIR CONDITIONER
PRECAUTIONS .......................................................... 4
Precautions for Supplemental Restraint System
(SRS) “AIR BAG” and “SEAT BELT PRE-TEN-
SIONER” .................................................................. 4
Precautions for Battery Service ................................ 4
Precautions for Procedures without Cowl Top Cover ..... 4
Precautions for Working with HFC-134a (R-134a) ..... 5
CONTAMINATED REFRIGERANT ....................... 5
General Refrigerant Precautions .............................. 6
Precautions for Refrigerant Connection ................... 7
ABOUT ONE-TOUCH JOINT ................................ 7
FEATURES OF NEW TYPE REFRIGERANT
CONNECTION ...................................................... 9
O-RING AND REFRIGERANT CONNECTION ... 10
Precautions for Servicing Compressor ................... 12
Precautions for Service Equipment ........................ 12
RECOVERY/RECYCLING EQUIPMENT ............ 12
ELECTRICAL LEAK DETECTOR ....................... 12
VACUUM PUMP ................................................. 12
MANIFOLD GAUGE SET .................................... 12
SERVICE HOSES ............................................... 13
SERVICE COUPLERS ........................................ 13
REFRIGERANT WEIGHT SCALE ...................... 13
CHARGING CYLINDER ...................................... 13
Precautions for Leak Detection Dye ....................... 14
IDENTIFICATION ................................................ 14
IDENTIFICATION LABEL FOR VEHICLE ........... 14
PREPARATION ......................................................... 15
Special Service Tools ............................................. 15
HFC-134a (R-134a) Service Tools and Equipment ... 16
Commercial Service Tools ...................................... 18
REFRIGERATION SYSTEM ..................................... 19
Refrigerant Cycle ................................................... 19
REFRIGERANT FLOW ....................................... 19
FREEZE PROTECTION ..................................... 19
Refrigerant System Protection ............................... 19
REFRIGERANT PRESSURE SENSOR ............. 19
PRESSURE RELIEF VALVE ............................... 19
Component Layout ................................................. 20LUBRICANT .............................................................. 21
Maintenance of Lubricant Quantity in Compressor ... 21
LUBRICANT ........................................................ 21
LUBRICANT RETURN OPERATION .................. 21
LUBRICANT ADJUSTING PROCEDURE FOR
COMPONENTS REPLACEMENT EXCEPT
COMPRESSOR .................................................. 22
LUBRICANT ADJUSTING PROCEDURE FOR
COMPRESSOR REPLACEMENT ....................... 23
AIR CONDITIONER CONTROL ............................... 24
Description of Air Conditioner LAN Control System ... 24
System Construction .............................................. 24
OPERATION ........................................................ 25
TRANSMISSION DATA AND TRANSMISSION
ORDER ............................................................... 25
AIR MIX DOOR CONTROL (AUTOMATIC TEM-
PERATURE CONTROL) ..................................... 26
FAN SPEED CONTROL ...................................... 26
INTAKE DOOR CONTROL ................................. 26
MODE DOOR CONTROL ................................... 26
MAGNET CLUTCH CONTROL ........................... 27
SELF-DIAGNOSIS SYSTEM .............................. 27
Description of Control System ................................ 28
Control Operation ................................................... 29
MODE CONTROL DIAL ...................................... 29
TEMPERATURE CONTROL DIAL (POTENTIO
TEMPERATURE CONTROL) .............................. 29
FAN CONTROL DIAL .......................................... 29
REAR WINDOW DEFOGGER SWITCH ............. 29
INTAKE SWITCH ................................................. 29
A/C SWITCH ....................................................... 29
Discharge Air Flow ................................................. 30
System Description ................................................. 31
SWITCHES AND THEIR CONTROL FUNCTION ... 31
CAN Communication System Description .............. 32
TROUBLE DIAGNOSIS ............................................ 33
CONSULT-III Function (BCM) ................................ 33
DATA MONITOR ................................................. 33
How to Perform Trouble Diagnosis for Quick and
Accurate Repair ...................................................... 34
Page 4 of 142
ATC-4
PRECAUTIONS
Revision: 2006 November2007 350Z
PRECAUTIONSPFP:00001
Precautions for Supplemental Restraint System (SRS) “AIR BAG” and “SEAT
BELT PRE-TENSIONER”
NJS000D2
The Supplemental Restraint System such as “AIR BAG” and “SEAT BELT PRE-TENSIONER”, used along
with a front seat belt, helps to reduce the risk or severity of injury to the driver and front passenger for certain
types of collision. This system includes seat belt switch inputs and dual stage front air bag modules. The SRS
system uses the seat belt switches to determine the front air bag deployment, and may only deploy one front
air bag, depending on the severity of a collision and whether the front occupants are belted or unbelted.
Information necessary to service the system safely is included in the SRS and SB section of this Service Man-
ual.
WARNING:
To avoid rendering the SRS inoperative, which could increase the risk of personal injury or death
in the event of a collision which would result in air bag inflation, all maintenance must be per-
formed by an authorized NISSAN/INFINITI dealer.
Improper maintenance, including incorrect removal and installation of the SRS, can lead to per-
sonal injury caused by unintentional activation of the system. For removal of Spiral Cable and Air
Bag Module, see the SRS section.
Do not use electrical test equipment on any circuit related to the SRS unless instructed to in this
Service Manual. SRS wiring harnesses can be identified by yellow and/or orange harnesses or
harness connectors.
Precautions for Battery ServiceNJS000D3
Before disconnecting the battery, lower both the driver and passenger windows. This will prevent any interfer-
ence between the window edge and the vehicle when the door is opened/closed. During normal operation, the
window slightly raises and lowers automatically to prevent any window to vehicle interference. The automatic
window function will not work with the battery disconnected.
Precautions for Procedures without Cowl Top CoverNJS000CP
When performing the procedure after removing cowl top cover, cover
the lower end of windshield with urethane, etc.
PIIB3706J
Page 12 of 142
ATC-12
PRECAUTIONS
Revision: 2006 November2007 350Z
Precautions for Servicing CompressorNJS00007
Plug all openings to prevent moisture and foreign matter from entering.
When the compressor is removed, store it in the same way at it is when mounted on the car.
When replacing or repairing compressor, follow “Maintenance of Lubricant Quantity in Compres-
sor” exactly. Refer to AT C - 2 1 , "
Maintenance of Lubricant Quantity in Compressor" .
Keep friction surfaces between clutch and pulley clean. If the surface is contaminated with lubri-
cant, wipe it off by using a clean waste cloth moistened with thinner.
After compressor service operation, turn the compressor shaft by hand more than five turns in
both directions. This will equally distribute lubricant inside the compressor. After the compressor
is installed, let the engine idle and operate the compressor for one hour.
After replacing the compressor magnet clutch, apply voltage to the new one and check for normal
operation.
Precautions for Service EquipmentNJS00008
RECOVERY/RECYCLING EQUIPMENT
Be certain to follow the manufacturer’s instructions for machine operation and machine maintenance. Never
introduce any refrigerant other than that specified into the machine.
ELECTRICAL LEAK DETECTOR
Be certain to follow the manufacturer’s instructions for tester operation and tester maintenance.
VACUUM PUMP
The lubricant contained inside the vacuum pump is not compatible
with the specified lubricant for HFC-134a (R-134a) A/C systems.
The vent side of the vacuum pump is exposed to atmospheric pres-
sure. So the vacuum pump lubricant may migrate out of the pump
into the service hose. This is possible when the pump is switched off
after evacuation (vacuuming) and hose is connected to it.
To prevent this migration, use a manual valve placed near the hose-
to-pump connection, as follows.
Usually vacuum pumps have a manual isolator valve as part of
the pump. Close this valve to isolate the service hose from the
pump.
For pumps without an isolator, use a hose equipped with a man-
ual shut-off valve near the pump end. Close the valve to isolate
the hose from the pump.
If the hose has an automatic shut-off valve, disconnect the hose
from the pump. As long as the hose is connected, the valve is
open and lubricating oil may migrate.
Some one-way valves open when vacuum is applied and close
under no vacuum condition. Such valves may restrict the pump’s
ability to pull a deep vacuum and are not recommended.
MANIFOLD GAUGE SET
Be certain that the gauge face indicates HFC-134a or R-134a. Be
sure the gauge set has 1/2″-16 ACME threaded connections for ser-
vice hoses. Confirm the set has been used only with refrigerant
HFC-134a (R-134a) and specified lubricants.
RHA270DA
SHA533D
Page 21 of 142
LUBRICANT
ATC-21
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: 2006 November2007 350Z
LUBRICANTPFP:KLG00
Maintenance of Lubricant Quantity in CompressorNJS0000I
The lubricant in the compressor circulates through the system with the refrigerant. Add lubricant to compres-
sor when replacing any component or after a large refrigerant leakage occurred. It is important to maintain the
specified amount.
If lubricant quantity is not maintained properly, the following malfunctions may result:
Lack of lubricant: May lead to a seized compressor.
Excessive lubricant: Inadequate cooling (thermal exchange interference)
LUBRICANT
LUBRICANT RETURN OPERATION
Adjust the lubricant quantity according to the test group shown below.
1. CHECK LUBRICANT RETURN OPERATION
Can lubricant return operation be performed?
A/C system works properly.
There is no evidence of a large amount of lubricant leakage.
CAUTION:
If excessive lubricant leakage is noted, never perform the lubricant return operation.
OK or NG
OK >> GO TO 2.
NG >> GO TO 3.
2. PERFORM LUBRICANT RETURN OPERATION, PROCEEDING AS FOLLOWS
1. Start the engine, and set to the following conditions:
–Engine speed: Idling to 1,200 rpm
–A/C switch: ON
–Blower speed: Max. position
–Temp. control: Optional [Set so that intake air temperature is 25 to 30°C (77 to 86°F).]
–Intake position: Recirculation (REC)
2. Perform lubricant return operation for about 10 minutes.
3. Stop the engine.
>> GO TO 3.
3. CHECK REPLACEMENT PART
Should the compressor be replaced?
YES >> GO TO AT C - 2 3 , "LUBRICANT ADJUSTING PROCEDURE FOR COMPRESSOR REPLACE-
MENT" .
NO >> GO TO AT C - 2 2 , "
LUBRICANT ADJUSTING PROCEDURE FOR COMPONENTS REPLACE-
MENT EXCEPT COMPRESSOR" . Name : Nissan A/C System Oil Type S
Page 90 of 142
ATC-90
TROUBLE DIAGNOSIS
Revision: 2006 November2007 350Z
NoiseNJS00018
SYMPTOM: Noise
INSPECTION FLOW
*1ATC-53, "Operational Check"*2ATC-126, "Check Disc to Pulley
Clearance"
*3AT C - 2 1 , "Maintenance of Lubricant
Quantity in Compressor"
*4EM-12, "Checking Drive Belts"
SJIA0843E
Page 139 of 142
REFRIGERANT LINES
ATC-139
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: 2006 November2007 350Z
Electrical Leak DetectorNJS0002A
PRECAUTIONS FOR HANDLING LEAK DETECTOR
When performing a refrigerant leak check, use an A/C electrical leak
detector (SST) or equivalent. Ensure that the instrument is calibrated
and set properly per the operating instructions.
The leak detector is a delicate device. In order to use the leak detec-
tor properly, read the operating instructions and perform any speci-
fied maintenance.
1. Position probe approximately 5 mm (3/16 in) away from point to
be checked.
2. When testing, circle each fitting completely with probe.
3. Move probe along component approximately 25 to 50 mm (1 to
2 in)/sec.
SHA196FA
SHA707EA
SHA706E
SHA708EA