fuse NISSAN 350Z 2007 Z33 Roof Workshop Manual
[x] Cancel search | Manufacturer: NISSAN, Model Year: 2007, Model line: 350Z, Model: NISSAN 350Z 2007 Z33Pages: 130, PDF Size: 5.4 MB
Page 40 of 130
RF-40
SOFT TOP
Revision: 2006 November2007 350Z
Check Soft Top Control Unit Power Supply (OP, CL)NIS0006K
1. CHECK FUSE
Check 10A fuse [No.12, located in the fuse block (J/B)]
Check 40A fusible link (letter G located in the fuse and fusible link box.)
NOTE:
Refer to RF-11, "
Component Parts and Harness Connector Location" .
OK or NG
OK >> GO TO 2.
NG >> If fuse blown out, be sure to eliminate cause of malfunction before installing new fuse. Refer to
PG-4, "
POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK POWER SUPPLY CIRCUIT
1. Start engine.
2. Check voltage between soft top control unit connector B66, 67
terminal 1, 8, 17 and ground.
OK or NG
OK >> GO TO 3.
NG >> Check soft top control unit power supply circuit for open
or short.
3. CHECK GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect soft top control unit connector.
3. Check continuity between soft top control unit connector B66
terminal 7, 16 and ground.
OK or NG
OK >> Power supply and ground circuit are OK.
NG >> Check soft top control unit ground circuit for open or
short.
Check Soft Top Switch (OPEN)NIS0006L
1. CHECK SOFT TOP OPEN SWITCH SIGNAL
1. Start engine.
2. Check soft top control unit connector and ground.
OK or NG
OK >> Soft top switch (OPEN) is OK.
NG >> GO TO 2.1 (W/R) - Ground : Battery voltage
8 (W/R) - Ground : Battery voltage
17 (R) - Ground : Battery voltage
PIIA7886E
7 (B) - Ground : Continuity should exist.
16 (B) - Ground : Continuity should exist.
PIIA7887E
ConnectorTerminal (Wire color)
Soft top switch
ConditionVoltage (V)
(Approx.)
(+) (-)
B67 18 (SB) GroundOPEN 0
Other than above 5
PIIA7888E
Page 79 of 130
SOFT TOP
RF-79
C
D
E
F
G
H
J
K
L
MA
B
RF
Revision: 2006 November2007 350Z
2. CHECK VEHICLE SPEED SIGNAL CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect soft top control unit and unified meter and A/C amp connector.
3. Check the following.
–Continuity between soft top control unit connector B66 terminal
14 and unified meter and A/C amp connector M49 terminal 26.
–Continuity between soft top control unit connector B66 terminal
14 and ground.
4. Check the following.
–Continuity between soft top control unit connector B67 terminal
23 and unified meter and A/C amp connector M49 terminal 34.
–Continuity between soft top control unit connector B67 terminal
23 and ground.
OK or NG
OK >> Check unified meter and A/C amp. Refer to DI-44, "Sys-
tem Description" .
NG >> Repair or replace harness.
3. CHECK FUSE
Check 10A fuse [No.20, located in fuse block (J/B)].
NOTE:
Refer to RF-11, "
Component Parts and Harness Connector Location" .
OK or NG
OK >> GO TO 4.
NG >> If fuse blown out, be sure to eliminate cause of malfunction before installing new fuse. Refer to
PG-4, "
POWER SUPPLY ROUTING CIRCUIT" .
4. CHECK BRAKE PEDAL SIGNAL
Check voltage between soft top control unit connector and ground.
OK or NG
OK >> Stop lamp switch is OK.
NG >> GO TO 5.14 (W) - 26 (W) : Continuity should exist.
14 (W) - Ground : Continuity should not exist.
PIIA7942E
23 (W/G) - 34 (L) : Continuity should exist.
23 (W/G) - Ground : Continuity should not exist.
PIIA7943E
ConnectorTerminal (Wire color)
Brake pedal condi-
tionVoltage (V)
(Approx.)
(+) (-)
B68 38 (W) GroundDepressed Battery voltage
Released 0
PIIA7944E
Page 85 of 130
SOFT TOP
RF-85
C
D
E
F
G
H
J
K
L
MA
B
RF
Revision: 2006 November2007 350Z
2. CHECK VEHICLE SPEED SIGNAL CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect soft top control unit and unified meter and A/C amp connector.
3. Check the following.
–Continuity between soft top control unit connector B66 terminal
14 and unified meter and A/C amp connector M49 terminal 26.
–Continuity between soft top control unit connector B66 terminal
14 and ground.
4. Check the following.
–Continuity between soft top control unit connector B67 terminal
23 and unified meter and A/C amp connector M49 terminal 34.
–Continuity between soft top control unit connector B67 terminal
23 and ground.
OK or NG
OK >> Check unified meter and A/C amp. Refer to DI-44, "Sys-
tem Description" .
NG >> Repair or replace harness.
Check Indicator Lamp CircuitNIS0007O
1. CHECK FUSE
Check 10A fuse [No.14, located in fuse block (J/B)]
NOTE:
Refer to RF-11, "
Component Parts and Harness Connector Location" .
OK or NG
OK >> GO TO 2.
NG >> If fuse blown out, be sure to eliminate cause of malfunction before installing new fuse. Refer to
PG-4, "
POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK INDICATOR LAMP SIGNAL
1. Start engine.
2. Soft top switch operate, check voltage between soft top control unit connector and ground.
OK or NG
OK >> Check the condition of the harness and the connector.
NG - 1 >> If battery voltage: Replace soft top control unit.
NG - 2 >> If 0V: GO TO 3.14 (W) - 26 (W) : Continuity should exist.
14 (W) - Ground : Continuity should not exist.
PIIA7942E
23 (W/G) - 34 (L) : Continuity should exist.
23 (W/G) - Ground : Continuity should not exist.
PIIA7943E
ConnectorTerminal (Wire color)
Roof conditionVoltage (V)
(Approx.)
(+) (-)
B67 35 (Y) GroundFull open or full close Battery voltage
Other than above 0
PIIB0835E