ignition NISSAN 350Z 2007 Z33 Roof Workshop Manual
[x] Cancel search | Manufacturer: NISSAN, Model Year: 2007, Model line: 350Z, Model: NISSAN 350Z 2007 Z33Pages: 130, PDF Size: 5.4 MB
Page 13 of 130
SOFT TOP
RF-13
C
D
E
F
G
H
J
K
L
MA
B
RF
Revision: 2006 November2007 350Z
CONDITIONS FOR OPERATION
Operation is avairable when all of the conditions below are satisfied.
Ignition switch is ON.
The brake pedal is ON.
Vehicle speed is 4 km/h (2 MPH) or less.
Battery voltage is approximately 10 V or more.
CAUTION:
Run the engine when operating or inspecting the soft top to prevent battery dies.
CONDITIONS FOR STOPPING OPERATION
Operation of the soft top stops when the conditions below are satisfied while the soft top is operating.
Any of the above operation conditions is no longer satisfied.
The passenger side power seat is operated. (It does not move when seat cancel switch is ON.)
OUTLINE OF OPERATION
Refer to the illustrations for the positions of the soft top, and the conditions of switch and actuator operation.
OPERATION: FULL CLOSE → FULL OPEN
Refer to RF-19, "State Chart" .
CONDITION: FULL CLOSE
CONDITION: OP 1
When the soft top switch is pushed to OPEN, the indicator lamp illuminates, windows activate to the fully-
open position and the passenger seat tilts forward by approximately 6 degrees by power window down
request signal. When passenger seat tilts forward by approximately 6 degrees, seat back position signal is
turned ON.
CONDITION: OP 2
The 5th bow unlock actuator operates, releasing the 5th bow lock.
Item Condition
5th bow half-latch switch : OFF
5th bow full-latch switch : OFF
5th bow ending switch : OFF
5th bow full open detection switch : OFF
5th bow full close detection switch : OFF
Storage lid full open detection switch : OFF
Storage lid full close detection switch LH : OFF
Storage lid full close detection switch RH : OFF
Roof full open detection switch : OFF
Roof full close detection switch : OFF
Body interference prevention switch : OFF
Roll bar interference prevention switch : OFF
Item Condition
Soft top switch : OPEN (Until the operation ends)
Indicator lamp : ON
Power window down request signal : ON
Seat back position signal : OFF → ON
Item Condition
5th bow unlock actuator : ON
Page 23 of 130
SOFT TOP
RF-23
C
D
E
F
G
H
J
K
L
MA
B
RF
Revision: 2006 November2007 350Z
Indicator LampNIS0006E
The indicator lights, turns off or blinks according to the operating state.
*: The soft top operates for approximately 30 seconds after turn ignition switch OFF.
Turns OFF : The open / close operation stops or completes or any switch is malfunctioning
Lights : The soft top is operating or the operation stops on the way
Blinks : The soft top cannot be operated, do not response or front lock is unlocked at
the fully closed position
State of roofThe operation stops when the soft top is,
Operation
full open or
full closein position on
the way
Operational condition Turning off Lighting Lighting
Out of operational
conditionWhen battery voltage decreases remarkably Turning off Lighting Lighting
Brake pedal is not depressed Turning off Lighting Lighting
Vehicle speed is 5 km/h (3 MPH) or more Turning off Lighting Lighting
Ignition switch: OFF Turning off Turning off* Turning off*
Malfunction ofany switch of the system Turning off Lighting Blinking
soft top control unit Blinking Blinking Blinking
vehicle speed signal Blinking Blinking Blinking
Page 33 of 130
SOFT TOP
RF-33
C
D
E
F
G
H
J
K
L
MA
B
RF
Revision: 2006 November2007 350Z
Terminal and Reference Value of Soft Top Control UnitNIS0006H
CLOSE → OPEN OPERATION
The operation chart for roof position. Refer to RF-19, "State Chart" .
Te r m i -
nal No.Wire
colorDescription
Condition
(Roof position: OP)Value (V)
(Approx.)
Signal nameInput/
Output
1 W/R Battery power supply Input — Battery voltage
3RRoof actuator RH
(OPEN) signalOutputOP8 → OP11 0 → Battery voltage → 0
Other than above 0
4G/R5th bow closure motor
(CLOSE) signalOutput — 0
5R/BStorage lid actuator RH
(OPEN) signalOutputOP6 → OP7
0 → Battery voltage → 0
OP12
Other than above 0
6 R 5th bow unlock actuator signal OutputOP2 → OP3 0 → Battery voltage → 0
Other than above 0
7 B Ground — — 0
8 W/R Battery power supply Input — Battery voltage
10 YRoof actuator RH
(CLOSE) signalOutput — 0
12 G/Y5th bow closure motor
(OPEN) signalOutputOP4 0 → Battery voltage → 0
Other than above 0
13 L/RStorage lid actuator RH
(CLOSE) signalOutputOP11 → OP12 0 → Battery voltage → 0
Other than above 0
14 W Speed signal (8 pulse)Input/
OutputSpeed meter operate
[When vehicle speed is
Approx. 40km/h (25 MPH)]
15 ORStorage lid unlock actuator LH and
RH signalOutputOP5 → OP6 0 → Battery voltage → 0
Other than above 0
16 B Ground — — 0
17 RIgnition switch
(ON or START)InputIgnition switch
(ON or START position)Battery voltage
18 SBSoft top switch
(OPEN) signalInputSoft top switch
open operate0
Other than above 5
19 R/WSoft top switch
(CLOSE) signalInputSoft top switch
close operate0
Other than above 5
20 W/BRoof full close detection switch
signalInput OP8 5 → 0
21 W/LRoof full open detection switch
signalInput OP11 5 → 0
22 W/RRoll bar interference prevention
switch signalInput OP9 5 → 0
PKIA1935E
Page 35 of 130
SOFT TOP
RF-35
C
D
E
F
G
H
J
K
L
MA
B
RF
Revision: 2006 November2007 350Z
OPEN → CLOSE OPERATION
The operation chart for roof position. Refer to RF-21, "State Chart" .
48 Y/BStorage lid actuator LH
(CLOSE) signalOutputOP11 → OP12 0 → Battery voltage → 0
Other than above 0 Te r m i -
nal No.Wire
colorDescription
Condition
(Roof position: OP)Value (V)
(Approx.)
Signal nameInput/
Output
Te r m i -
nal No.Wire
colorDescription
Condition
(Roof position: CL)Va l u e ( V )
(Approx.)
Signal name Input/
Output
1 W/R Battery power supply Input — Battery voltage
3RRoof actuator RH
(OPEN) signalOutput — 0
4 G/R5th bow closure motor
(CLOSE) signalOutputCL10 0 → Battery voltage → 0
Other than above 0
5R/BStorage lid actuator RH
(OPEN) signalOutputCL2 → CL3
0 → Battery voltage → 0
CL8
Other than above 0
6 R 5th bow unlock actuator signal Output — 0
7 B Ground — — 0
8 W/R Battery power supply Input — Battery voltage
10 YRoof actuator RH
(CLOSE) signalOutputCL3 → CL6 0 → Battery voltage → 0
Other than above 0
12 G/Y5th bow closure motor
(OPEN) signalOutput — 0
13 L/RStorage lid actuator RH
(CLOSE) signalOutputCL7 → CL8 0 → Battery voltage → 0
Other than above 0
14 W Speed signal (8 pulse)Input/
OutputSpeed meter operate
[When vehicle speed is
Approx. 40 km/h (25 MPH)]
15 ORStorage lid unlock actuator LH
and RH signalOutputCL1 → CL2 0 → Battery voltage → 0
Other than above 0
16 B Ground — — 0
17 RIgnition switch
(ON or START)InputIgnition switch
(ON or START position)Battery voltage
18 SBSoft top switch
(OPEN) signalInputSoft top switch
open operate0
Other than above 5
19 R/WSoft top switch
(CLOSE) signalInputSoft top switch
close operate0
Other than above 5
20 W/BRoof full close detection
switch signalInput CL6 0 → 5
21 W/LRoof full open detection switch
signalInput CL3 0 → 5
PKIA1935E
Page 40 of 130
RF-40
SOFT TOP
Revision: 2006 November2007 350Z
Check Soft Top Control Unit Power Supply (OP, CL)NIS0006K
1. CHECK FUSE
Check 10A fuse [No.12, located in the fuse block (J/B)]
Check 40A fusible link (letter G located in the fuse and fusible link box.)
NOTE:
Refer to RF-11, "
Component Parts and Harness Connector Location" .
OK or NG
OK >> GO TO 2.
NG >> If fuse blown out, be sure to eliminate cause of malfunction before installing new fuse. Refer to
PG-4, "
POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK POWER SUPPLY CIRCUIT
1. Start engine.
2. Check voltage between soft top control unit connector B66, 67
terminal 1, 8, 17 and ground.
OK or NG
OK >> GO TO 3.
NG >> Check soft top control unit power supply circuit for open
or short.
3. CHECK GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect soft top control unit connector.
3. Check continuity between soft top control unit connector B66
terminal 7, 16 and ground.
OK or NG
OK >> Power supply and ground circuit are OK.
NG >> Check soft top control unit ground circuit for open or
short.
Check Soft Top Switch (OPEN)NIS0006L
1. CHECK SOFT TOP OPEN SWITCH SIGNAL
1. Start engine.
2. Check soft top control unit connector and ground.
OK or NG
OK >> Soft top switch (OPEN) is OK.
NG >> GO TO 2.1 (W/R) - Ground : Battery voltage
8 (W/R) - Ground : Battery voltage
17 (R) - Ground : Battery voltage
PIIA7886E
7 (B) - Ground : Continuity should exist.
16 (B) - Ground : Continuity should exist.
PIIA7887E
ConnectorTerminal (Wire color)
Soft top switch
ConditionVoltage (V)
(Approx.)
(+) (-)
B67 18 (SB) GroundOPEN 0
Other than above 5
PIIA7888E
Page 41 of 130
SOFT TOP
RF-41
C
D
E
F
G
H
J
K
L
MA
B
RF
Revision: 2006 November2007 350Z
2. CHECK SOFT TOP SWITCH GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect soft top switch connector.
3. Check continuity between soft top switch connector M14 termi-
nal 1 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CHECK SOFT TOP SWITCH
Soft top switch operate, check continuity between soft top switch connector M14 terminal 1 and 3.
OK or NG
OK >> GO TO 4.
NG >> Replace soft top switch.
4. CHECK SOFT TOP SWITCH CIRCUIT
1. Check continuity between soft top control unit connector B67 terminal 18 and soft top switch connector
M14 terminal 3.
2. Check continuity between soft top control unit connector B67
terminal 18 and ground.
OK or NG
OK >> GO TO 5.
NG >> Repair or replace harness.1 (B) - Ground : Continuity should exist.
PIIA7889E
Connector TerminalSoft top switch
ConditionContinuity
M14 1 3OPEN Yes
Other than above No
PIIA7890E
ConnectorTerminal
(Wire color)
ConnectorTerminal
(Wire color)
Continuity
(+) (-)
B67 18 (SB) M14 3 (L/B) No
M14 3 (L/B) B67 18 (SB) Yes
18 (SB) - Ground : Continuity should not exist.PIIB0833E
Page 42 of 130
RF-42
SOFT TOP
Revision: 2006 November2007 350Z
5. CHECK SOFT TOP CONTROL UNIT OUTPUT SIGNAL
1. Connect soft top control unit connector.
2. Start engine.
3. Check voltage between soft top control unit connector B67 ter-
minal 18 and ground.
OK or NG
OK >> Check condition of harness and connector.
NG >> Replace soft top control unit.
Check Soft Top Switch (CLOSE)NIS0006M
1. CHECK SOFT TOP CLOSE SWITCH SIGNAL
1. Start engine.
2. Check soft top control unit connector and ground.
OK or NG
OK >> Soft top switch (CLOSE) is OK.
NG >> GO TO 2.
2. CHECK SOFT TOP SWITCH GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect soft top switch connector.
3. Check continuity between soft top switch connector M14 termi-
nal 1 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.18 (SB) - Ground : Approx. 5V
PIIA7888E
ConnectorTerminal (Wire color)
Soft top
switch ConditionVoltage (V)
(Approx.)
(+) (-)
B67 19 (R/W) GroundCLOSE 0
Other than above 5
PIIA7892E
1 (B) - Ground : Continuity should exist.
PIIA7889E
Page 44 of 130
RF-44
SOFT TOP
Revision: 2006 November2007 350Z
Check 5th Bow Unlock Actuator (Open Operate)NIS0006N
1. CHECK 5TH BOW UNLOCK ACTUATOR SIGNAL
1. Start engine.
2. Operate soft top switch OPEN, check voltage between soft top
control unit connector and ground.
OK or NG
OK >> GO TO 2.
NG >> Replace soft top control unit.
2. CHECK 5TH BOW UNLOCK ACTUATOR GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect 5th bow unlock actuator connector.
3. Check continuity between 5th bow unlock actuator connector
T203 terminal 1 and ground.
OK or NG
OK >> Replace 5th bow unlock actuator.
NG >> Repair or replace harness.
Check 5th Bow Half-Latch Switch (Open Operate)NIS0006O
1. CHECK 5TH BOW HALF-LATCH SWITCH SIGNAL CHECK
1. Start engine.
2. Operate soft top switch OPEN, check voltage between soft top control unit connector and ground.
OK or NG
OK >> Soft top lock switch (5th bow half-latch switch) is OK.
NG >> GO TO 2.
Con-
nectorTerminal (Wire color)
Roof ConditionVoltage (V)
(Approx.)
(+) (-)
B66 6 (R) Ground OP1 → OP2 0 → Battery voltage
PIIA7895E
1 (B) - Ground : Continuity should exist.
PIIA7896E
ConnectorTerminal (Wire color)
Roof conditionVoltage (V)
(Approx.)
(+) (-)
B67 31 (L) Ground OP2 → OP3 5 → 0
PIIA7897E
Page 45 of 130
SOFT TOP
RF-45
C
D
E
F
G
H
J
K
L
MA
B
RF
Revision: 2006 November2007 350Z
2. CHECK 5TH BOW HALF-LATCH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect soft top control unit and soft top lock switch (at 5th bow lock assembly in storage lid) connec-
tor.
3. Check continuity between soft top control unit connector B67
terminal 31 and soft top lock switch connector T205 terminal 5.
4. Check continuity between soft top control unit connector B67
terminal 31 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CHECK 5TH BOW HALF-LATCH SWITCH GROUND CIRCUIT
Check continuity between soft top lock switch connector T205 terminal 6 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
4. CHECK SOFT TOP CONTROL UNIT OUTPUT SIGNAL
1. Connect soft top control unit connector.
2. Start engine.
3. Check voltage between soft top control unit connector B67 ter-
minal 31 and ground.
OK or NG
OK >> Replace Soft top lock switch (5th bow lock assembly in
storage lid).
NG >> Replace soft top control unit.31 (L) - 5 (L) : Continuity should exist.
31 (L) - Ground : Continuity should not exist.
PIIA7898E
6 (B) - Ground : Continuity should exist.
PIIA7899E
31 (L) - Ground : Approx. 5V
PIIA7897E
Page 46 of 130
RF-46
SOFT TOP
Revision: 2006 November2007 350Z
Check 5th Bow Actuator (Open Operate)NIS0006P
1. CHECK 5TH BOW ACTUATOR INPUT SIGNAL
1. Start engine.
2. Operate soft top switch OPEN, check voltage between 5th bow
actuator connector and ground.
OK or NG
OK >> Replace 5th bow actuator.
NG >> GO TO 2.
2. CHECK 5TH BOW ACTUATOR CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect soft top control unit and 5th bow actuator connector.
3. Check continuity between soft top control unit connector B68
terminal 44, 45 and 5ht bow actuator connector B233 terminal 1,
2.
4. Check continuity between soft top control unit connector B68
terminal 44, 45 and ground.
OK or NG
OK >> Replace soft top control unit.
NG >> Repair or replace harness.
Check 5th Bow Full Close Detection Switch (Open Operate)NIS0006Q
1. CHECK 5TH BOW FULL CLOSE DETECTION SWITCH SIGNAL
1. Start engine.
2. Operate soft top switch OPEN, check voltage between soft top control unit connector and ground.
OK or NG
OK >> Plate rail RR (5th bow full close switch) is OK.
NG >> GO TO 2.
Con-
nectorTerminal (Wire color)
Roof conditionVoltage (V)
(Approx.)
(+) (-)
B233 2 (G/R) Ground OP2 → OP3 0 → Battery voltage
PIIB9113E
44 (G/R) - 1 (G/Y) : Continuity should exist.
45 (G/Y) - 2 (G/R) : Continuity should exist.
44 (G/R) - Ground : Continuity should not exist.
45 (G/Y) - Ground : Continuity should not exist.
PIIA7901E
ConnectorTerminal (Wire color)
Roof conditionVoltage (V)
(Approx.)
(+) (-)
B67 27 (GY) Ground OP3 → OP4 5 → 0
PIIA7902E