engine NISSAN MURANO HYBRID 2016 3.G First Responders Guide

NISSAN MURANO HYBRID 2016 3.G First Responders Guide MURANO HYBRID 2016 3.G NISSAN NISSAN https://www.carmanualsonline.info/img/5/490/w960_490-0.png NISSAN MURANO HYBRID 2016 3.G First Responders Guide

Page 3 of 44

NISSAN MURANO HYBRID 2016 3.G First Responders Guide Table of Contents
FOREWORD
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FRG–2
NISSAN EMERGENCY CONTACT INFORM

Page 5 of 44

NISSAN MURANO HYBRID 2016 3.G First Responders Guide 1. About the Murano HYBRID
This
hybrid electric vehicle (HEV) uses two types of batteries. One is a 12-volt battery that is the same as
the battery in vehicles powered by internal combustion engines.

Page 6 of 44

NISSAN MURANO HYBRID 2016 3.G First Responders Guide 1-1 MURANO HYBRID IDENTIFICATION
1-1.1
Exterior and Engine Compartment AAYIA0423ZZ
FRG–6

Page 10 of 44

NISSAN MURANO HYBRID 2016 3.G First Responders Guide 2. Basic High-voltage System and 12-volt System Information
2-1
Battery Information
The Murano HYBRID utilizes two batteries in order to supply both high and low voltage.
2-1.1 12-Volt Battery • The

Page 12 of 44

NISSAN MURANO HYBRID 2016 3.G First Responders Guide No. Component
LocationDescription
� DC/DC
Converter Inside the centerconsole area
(mounted right of
high-voltage battery) The DC/DC converter reduces the voltage of
the high-voltage battery to provide

Page 13 of 44

NISSAN MURANO HYBRID 2016 3.G First Responders Guide 2-4 High-voltage Safety Measures
Circuit insulation
The high-voltage positive (+) and negative (-) circuits are insulated
from the metal chassis.
Reducing the risk of electrocution The high-voltage co

Page 15 of 44

NISSAN MURANO HYBRID 2016 3.G First Responders Guide • The high-voltage system and high-voltage capacitor may remain powered for up to
approximately 10 minutes after the vehicle is shut off. Appropriate Personal Protective
Equipment (PPE) must always

Page 18 of 44

NISSAN MURANO HYBRID 2016 3.G First Responders Guide 3-1 Preparation Items
Preparation Items
SpecificationPurpose
PPE
(personal protective equipment): Up to 1,000V For protection from high-
voltage electrical shock.
Insulated gloves Insulated shoes
–

Page 23 of 44

NISSAN MURANO HYBRID 2016 3.G First Responders Guide Powering Down the High-voltage System
The
high-voltage system can be shut down with any 1 of the following procedures:• Turn OFF the ignition switch and disconnect the 12-volt battery. Refer to Prim

Page 27 of 44

NISSAN MURANO HYBRID 2016 3.G First Responders Guide Alternate Procedure 2 (Remove Service Plug)
DANGER
• Do not remove the service plug without always wearing appropriate Personal
Protective Equipment (PPE) to help protect the responder from serious
Page:   1-10 11-20 next >