can NISSAN TEANA 2003 Service Manual
[x] Cancel search | Manufacturer: NISSAN, Model Year: 2003, Model line: TEANA, Model: NISSAN TEANA 2003Pages: 3502, PDF Size: 74.56 MB
Page 1963 of 3502
![NISSAN TEANA 2003 Service Manual EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-681
[VQ]
C
D
E
F
G
H
I
J
K
L
MA
EC
3. CHECK EVAP PURGE LINE
Check EVAP purge line (pipe, rubber tube, fuel tank and EVAP canister) for cracks or NISSAN TEANA 2003 Service Manual EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-681
[VQ]
C
D
E
F
G
H
I
J
K
L
MA
EC
3. CHECK EVAP PURGE LINE
Check EVAP purge line (pipe, rubber tube, fuel tank and EVAP canister) for cracks or](/img/5/57392/w960_57392-1962.png)
EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-681
[VQ]
C
D
E
F
G
H
I
J
K
L
MA
EC
3. CHECK EVAP PURGE LINE
Check EVAP purge line (pipe, rubber tube, fuel tank and EVAP canister) for cracks or improper connection.
Refer to EC-367, "
EVAPORATIVE EMISSION LINE DRAWING" .
OK or NG
OK >> GO TO 4.
NG >> Repair or reconnect the hose.
4. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIR-
CUIT
1. Turn ignition switch OFF.
2. Disconnect EVAP canister purge volume control solenoid valve
harness connector.
3. Turn ignition switch ON.
4. Check voltage between EVAP canister purge volume control
solenoid valve terminal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 6.
NG >> GO TO 5.
5. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E11, E253
Harness connectors E102, M57
Harness connectors F103, M52
Harness connectors F1, F251
Harness for open or short between EVAP canister purge volume control solenoid valve and IPDM E/R
Harness for open or short between EVAP canister purge volume control solenoid valve and ECM
>> Repair harness or connectors.
PBIB2107E
Voltage: Battery voltage
PBIB0148E
Page 1964 of 3502
![NISSAN TEANA 2003 Service Manual EC-682
[VQ]
EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
6. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIR-
CUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Di NISSAN TEANA 2003 Service Manual EC-682
[VQ]
EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
6. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIR-
CUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Di](/img/5/57392/w960_57392-1963.png)
EC-682
[VQ]
EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
6. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIR-
CUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 45 and EVAP canister purge volume control solenoid
valve terminal 2. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK (With CONSULT-II)>>GO TO 8.
OK (Without CONSULT-II)>>GO TO 9.
NG >> GO TO 7.
7. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors F1, F251
Harness for open or short between EVAP canister purge volume control solenoid valve and ECM.
>> Repair open circuit or short to ground or short to power in harness or connectors.
8. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
With CONSULT-II
1. Reconnect all harness connectors disconnected.
2. Start engine.
3. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode with
CONSULT-II. Check that engine speed varies according to the
valve opening.
OK or NG
OK >> GO TO 10.
NG >> GO TO 9.
9. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Refer to EC-683, "
Component Inspection" .
OK or NG
OK >> GO TO 10.
NG >> Replace EVAP canister purge volume control solenoid valve.
10. CHECK INTERMITTENT INCIDENT
Refer to EC-450, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END Continuity should exist.
PBIB0147E
Page 1965 of 3502
![NISSAN TEANA 2003 Service Manual EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-683
[VQ]
C
D
E
F
G
H
I
J
K
L
MA
EC
Component InspectionBBS0056F
EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-II
Check air pass NISSAN TEANA 2003 Service Manual EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-683
[VQ]
C
D
E
F
G
H
I
J
K
L
MA
EC
Component InspectionBBS0056F
EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-II
Check air pass](/img/5/57392/w960_57392-1964.png)
EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-683
[VQ]
C
D
E
F
G
H
I
J
K
L
MA
EC
Component InspectionBBS0056F
EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-II
Check air passage continuity of EVAP canister purge volume control
solenoid valve using “ACTIVE TEST” mode with CONSULT-II under
the following conditions.
Without CONSULT-II
Check air passage continuity of EVAP canister purge volume control
solenoid valve under the following conditions.
Removal and InstallationBBS0056G
EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Refer to EM-133, "INTAKE MANIFOLD COLLECTOR" .
Condition
(PURG VOL CONT/V value)Air passage continuity
between A and B
100% Yes
0% No
PBIB0149E
ConditionAir passage continuity
between A and B
12V direct current supply between
terminals 1 and 2Ye s
No supply No
PBIB0150E
Page 1968 of 3502
![NISSAN TEANA 2003 Service Manual EC-686
[VQ]
FUEL INJECTOR
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals NISSAN TEANA 2003 Service Manual EC-686
[VQ]
FUEL INJECTOR
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals](/img/5/57392/w960_57392-1967.png)
EC-686
[VQ]
FUEL INJECTOR
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)
Diagnostic ProcedureBBS0056M
1. INSPECTION START
Turn ignition switch to START.
Is any cylinder ignited?
Ye s o r N o
Yes (With CONSULT-II)>>GO TO 2.
Yes (Without CONSULT-II)>>GO TO 3.
No >> GO TO 7.
2. CHECK OVERALL FUNCTION
With CONSULT-II
1. Start engine.
2. Perform “POWER BALANCE” in “ACTIVE TEST” mode with
CONSULT-II.
3. Make sure that each circuit produces a momentary engine
speed drop.
OK or NG
OK >>INSPECTION END
NG >> GO TO 7.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
21
22
23
40
41
42L/W
R/Y
R/B
P/B
LG/R
R/WFuel injector No. 5
Fuel injector No. 3
Fuel injector No. 1
Fuel injector No. 6
Fuel injector No. 4
Fuel injector No. 2[Engine is running]
Warm-up condition
Idle speed
NOTE:
The pulse cycle changes depending on rpm at
idleBATTERY VOLTAGE
(11 - 14V)
[Engine is running]
Warm-up condition
Engine speed: 2,000 rpmBATTERY VOLTAGE
(11 - 14V)
SEC984C
SEC985C
PBIB0133E
Page 1980 of 3502
![NISSAN TEANA 2003 Service Manual EC-698
[VQ]
HO2S1
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when mea NISSAN TEANA 2003 Service Manual EC-698
[VQ]
HO2S1
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when mea](/img/5/57392/w960_57392-1979.png)
EC-698
[VQ]
HO2S1
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
2OHeated oxygen sensor 1
heater (Bank 1)[Engine is running]
Warm-up condition
Engine speed: Below 3,600 rpmApproximately 5V
[Engine is running]
Engine speed: Above 3,600 rpmBATTERY VOLTAGE
(11 - 14V)
35 WHeated oxygen sensor 1
(Bank 1)[Engine is running]
Warm-up condition
Engine speed: 2,000 rpm0 - Approximately 1.0V
(Periodically change)
78 BSensor ground
(Heated oxygen sensor)[Engine is running]
Warm-up condition
Idle speedApproximately 0V
PBIB0519E
Page 1982 of 3502
![NISSAN TEANA 2003 Service Manual EC-700
[VQ]
HO2S1
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when mea NISSAN TEANA 2003 Service Manual EC-700
[VQ]
HO2S1
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when mea](/img/5/57392/w960_57392-1981.png)
EC-700
[VQ]
HO2S1
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECMs transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)
Diagnostic ProcedureBBS0055R
1. INSPECTION START
Do you have CONSULT-II?
Ye s o r N o
Yes >> GO TO 2.
No >> GO TO 3.
2. CHECK OVERALL FUNCTION
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select “HO2S1 MNTR (B1)” and “HO2S1 MNTR (B2)” in “DATA
MONITOR” mode with CONSULT-II.
3. Keep the engine speed at 2,000 rpm under no load, and make
sure that the monitors fluctuate between LEAN and RICH more
than 5 times in 10 seconds.
OK or NG
OK >>INSPECTION END
NG >> GO TO 4.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
24 R/LHeated oxygen sensor 1
heater (Bank 2)[Engine is running]
Warm-up condition
Engine speed: Below 3,600 rpmApproximately 8V
[Engine is running]
Warm-up condition
Engine speed: Above 3,600 rpmBATTERY VOLTAGE
(11 - 14V)
16 WHeated oxygen sensor 1
(Bank 2)[Engine is running]
Warm-up condition
Engine speed: 2,000 rpm0 - Approximately 1.0V
(Periodically change)
78 BSensor ground
(Heated oxygen sensor)[Engine is running]
Warm-up condition
Idle speedApproximately 0V
PBIB0519E
1 time: RICH → LEAN → RICH
2 time: RICH → LEAN → RICH → LEAN → RICH
PBIB0120E
Page 1986 of 3502
![NISSAN TEANA 2003 Service Manual EC-704
[VQ]
HO2S1
Component InspectionBBS0055S
HEATED OXYGEN SENSOR 1
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select “MANU TRIG” and adjust “TRIGGE NISSAN TEANA 2003 Service Manual EC-704
[VQ]
HO2S1
Component InspectionBBS0055S
HEATED OXYGEN SENSOR 1
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select “MANU TRIG” and adjust “TRIGGE](/img/5/57392/w960_57392-1985.png)
EC-704
[VQ]
HO2S1
Component InspectionBBS0055S
HEATED OXYGEN SENSOR 1
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select “MANU TRIG” and adjust “TRIGGER POINT” to 100% in “DATA MONITOR” mode with CONSULT-
II.
3. Select “HO2S1 (B1)/(B2)” and “HO2S1 MNTR (B1)/(B2)”.
4. Hold engine speed at 2,000 rpm under no load during the following steps.
5. Touch “RECORD” on CONSULT-II screen.
6. Check the following.
“HO2S1 MNTR (B1)/(B2)” in “DATA MONITOR” mode
changes from “RICH” to “LEAN” to “RICH” more than 5 times
in 10 seconds.
5 times (cycles) are counted as shown in the figure.
“HO2S1 (B1)/(B2)” voltage goes above 0.6V at least once.
“HO2S1 (B1)/(B2)” voltage goes below 0.3V at least once.
“HO2S1 (B1)/(B2)” voltage never exceeds 1.0V.
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7
in) onto a hard surface such as a concrete floor; use a new one.
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread
Cleaner and approved anti-seize lubricant.
SEF646Y
SEF647Y
SEF648Y
Page 1987 of 3502
![NISSAN TEANA 2003 Service Manual HO2S1
EC-705
[VQ]
C
D
E
F
G
H
I
J
K
L
MA
EC
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Set voltmeter probes between ECM terminal 35 [HO2S1 (B1) signal] or NISSAN TEANA 2003 Service Manual HO2S1
EC-705
[VQ]
C
D
E
F
G
H
I
J
K
L
MA
EC
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Set voltmeter probes between ECM terminal 35 [HO2S1 (B1) signal] or](/img/5/57392/w960_57392-1986.png)
HO2S1
EC-705
[VQ]
C
D
E
F
G
H
I
J
K
L
MA
EC
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Set voltmeter probes between ECM terminal 35 [HO2S1 (B1) signal] or 16 [HO2S1 (B2) signal] and
ground.
3. Check the following with engine speed held at 2,000 rpm con-
stant under no load.
The voltage fluctuates between 0 to 0.3V and 0.6 to 1.0V
more than 5 times within 10 seconds.
The maximum voltage is over 0.6V at least one time.
The minimum voltage is below 0.3V at least one time.
The voltage never exceeds 1.0V.
1 time: 0 - 0.3V → 0.6 - 1.0V → 0 - 0.3V
2 times: 0 - 0.3V → 0.6 - 1.0V → 0 - 0.3V → 0.6 - 1.0V → 0 -
0.3V
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7
in) onto a hard surface such as a concrete floor; use a new one.
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread
Cleaner and approved anti-seize lubricant.
Removal and InstallationBBS0055T
HEATED OXYGEN SENSOR 1
Refer to EM-140, "EXHAUST MANIFOLD AND THREE WAY CATALYST" .
PBIB1107E
Page 1990 of 3502
![NISSAN TEANA 2003 Service Manual EC-708
[VQ]
HO2S1 HEATER
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals w NISSAN TEANA 2003 Service Manual EC-708
[VQ]
HO2S1 HEATER
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals w](/img/5/57392/w960_57392-1989.png)
EC-708
[VQ]
HO2S1 HEATER
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
2OHeated oxygen sensor 1
heater (Bank 1)[Engine is running]
Warm-up condition
Engine speed: Below 3,600 rpmApproximately 5V
[Engine is running]
Engine speed: Above 3,600 rpmBATTERY VOLTAGE
(11 - 14V)
35 WHeated oxygen sensor 1
(Bank 1)[Engine is running]
Warm-up condition
Engine speed: 2,000 rpm0 - Approximately 1.0V
(Periodically change)
78 BSensor ground
(Heated oxygen sensor)[Engine is running]
Warm-up condition
Idle speedApproximately 0V
PBIB0519E
Page 1992 of 3502
![NISSAN TEANA 2003 Service Manual EC-710
[VQ]
HO2S1 HEATER
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals w NISSAN TEANA 2003 Service Manual EC-710
[VQ]
HO2S1 HEATER
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals w](/img/5/57392/w960_57392-1991.png)
EC-710
[VQ]
HO2S1 HEATER
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECMs transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
24 R/LHeated oxygen sensor 1
heater (Bank 2)[Engine is running]
Warm-up condition
Engine speed: Below 3,600 rpmApproximately 8V
[Engine is running]
Warm-up condition
Engine speed: Above 3,600 rpmBATTERY VOLTAGE
(11 - 14V)
16 WHeated oxygen sensor 1
(Bank 2)[Engine is running]
Warm-up condition
Engine speed: 2,000 rpm0 - Approximately 1.0V
(Periodically change)
78 BSensor ground
(Heated oxygen sensor)[Engine is running]
Warm-up condition
Idle speedApproximately 0V
PBIB0519E