ignition NISSAN TEANA 2003 Manual Online
[x] Cancel search | Manufacturer: NISSAN, Model Year: 2003, Model line: TEANA, Model: NISSAN TEANA 2003Pages: 3502, PDF Size: 74.56 MB
Page 437 of 3502

TROUBLE DIAGNOSIS
ATC-59
C
D
E
F
G
H
I
K
L
MA
B
AT C
LAN System CircuitBJS000G0
SYMPTOM: Mode door motor, intake door motor and/or air mix door motor(s) does not operate normally.
DIAGNOSIS PROCEDURE FOR LAN CIRCUIT
1. CHECK POWER SUPPLY FOR UNIFIED METER AND A/C AMP.
1. Turn ignition switch ON.
2. Check voltage between unified meter and A/C amp. harness
connector M45 terminal 54 and ground.
OK or NG
OK >> GO TO 2.
NG >> Replace unified meter and A/C amp.
2. CHECK SIGNAL FOR UNIFIED METER AND A/C AMP.
Confirm A/C LAN signal between unified meter and A/C amp. har-
ness connector M45 terminal 43 and ground using an oscilloscope.
OK or NG
OK >> GO TO 3.
NG >> Replace unified meter and A/C amp.
RJIA1775E
54 – Ground : Battery voltage
RJIA1986E
Terminals
Voltag e (+)
(-) Unified meter
and A/C amp.
connectorTe r m i n a l N o .
M45 43 Ground
RJIA1987E
SJIA1453J
Page 438 of 3502

ATC-60
TROUBLE DIAGNOSIS
3. CHECK POWER SUPPLY FOR EACH DOOR MOTOR
Check voltage between each door motor harness connector M252,
M253, M254 and M255 terminal 1 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair harness or connector.
4. CHECK SIGNAL FOR EACH DOOR MOTOR
Confirm A/C LAN signal between each door motor harness connec-
tor terminal 3 and ground using an oscilloscope.
OK or NG
OK >> GO TO 5.
NG >> Repair harness or connector.
5. CHECK MOTOR GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect each door motor connector.
3. Check continuity between each door motor harness connector
M252, M253, M254 and M255 terminal 2 and ground.
OK or NG
OK >> GO TO 6.
NG >> Repair harness or connector.1 – Ground : Battery voltage
RJIA1988E
Door
motorTe r m i n a l s
Voltage (+)
(-)
Con-
nectorTerminal
No.
Mode M252 3
Ground Air mix
(Driver
side)M253 3
Air mix
(Passen-
ger side)M254 3
Intake M255 3
RJIA1989E
SJIA1453J
2 – Ground : Continuity should exist.
RJIA1990E
Page 439 of 3502

TROUBLE DIAGNOSIS
ATC-61
C
D
E
F
G
H
I
K
L
MA
B
AT C
6. CHECK MOTOR OPERATION
1. Reconnect each door motor connector.
2. Turn ignition switch ON.
3. Confirm operation of each door motor.
OK or NG
OK >> (Return to operate normally.)
Poor contact in motor connector.
NG >> (Does not operate normally.)
GO TO 7.
7. CHECK AIR MIX DOOR MOTOR AND INTAKE DOOR MOTOR OPERATION
1. Turn ignition switch OFF.
2. Disconnect mode, air mix (driver side, passenger side), and intake door motor connectors.
3. Reconnect air mix (driver side, passenger side) and intake door motor connectors.
4. Turn ignition switch ON.
5. Confirm operation of air mix door motor (driver side, passenger side) and intake door motor.
OK or NG
OK >> [Air mix (driver side, passenger side) and intake door motors operate normally.]
Replace mode door motor.
NG >> [Air mix (driver side, passenger side) and intake door motors does not operate normally.]
GO TO 8.
8. CHECK MODE DOOR MOTOR AND INTAKE DOOR MOTOR OPERATION
1. Turn ignition switch OFF.
2. Disconnect air mix door motor (driver side, passenger side) connectors.
3. Reconnect mode door motor connector.
4. Turn ignition switch ON.
5. Confirm operation of mode door motor and intake door motor.
OK or NG
OK >> (Mode and intake door motors operate normally.)
GO TO 10.
NG >> (Mode and intake door motors does not operate normally.)
GO TO 9.
9. CHECK MODE DOOR MOTOR AND AIR MIX DOOR MOTOR OPERATION
1. Turn ignition switch OFF.
2. Disconnect intake door motor connector.
3. Reconnect air mix door motor (driver side, passenger side) connectors.
4. Turn ignition switch ON.
5. Confirm operation of mode door motor and air mix door motor (driver side, passenger side).
OK or NG
OK >> [Mode and air mix door motor (driver side, passenger side) operate normally.]
Replace intake door motor.
NG >> [Mode and air mix door motor (driver side, passenger side) does not operate normally.]
Replace unified meter and A/C amp.
Page 440 of 3502

ATC-62
TROUBLE DIAGNOSIS
10. CHECK AIR MIX DOOR MOTOR OPERATION
1. Turn ignition switch OFF.
2. Disconnect air mix door motor (driver side) connector.
3. Turn ignition switch ON.
4. Confirm operation of air mix door motor (passenger side).
OK or NG
OK >> [Air mix door motor (passenger side) operates normally.]
Replace air mix door motor (driver side).
NG >> [Air mix door motor (passenger side) does not operate normally.]
Replace air mix door motor (passenger side).
Page 453 of 3502

TROUBLE DIAGNOSIS
ATC-75
C
D
E
F
G
H
I
K
L
MA
B
AT C
1. CHECK POWER SUPPLY FOR BLOWER MOTOR
1. Disconnect blower motor connector.
2. Turn ignition switch ON.
3. Check voltage between blower motor harness connector M48
terminal 1 and ground.
OK or NG
OK >> GO TO 2.
NG >> Check power supply circuit and 15A fuses [Nos. 10 and
11, located in the fuse block (J/B)]. Refer to PG-79,
"FUSE BLOCK - JUNCTION BOX (J/B)" .
If fuses are OK, check harness for open circuit. Repair or replace if necessary.
If fuses are NG, check harness for short circuit and replace fuse.
2. CHECK FAN FEEDBACK CIRCUIT
1. Turn ignition switch OFF.
2. Reconnect blower motor connector.
3. Turn ignition switch ON.
4. Check voltage between unified meter and A/C amp. harness
connector M45 terminal 47 and ground.
OK or NG
OK >> GO TO 3.
NG >> GO TO 9.
3. CHECK BLOWER MOTOR
Check blower motor. Refer to AT C - 7 7 , "
Blower Motor" .
OK or NG
OK >> GO TO 4.
NG >> Replace blower motor.
4. CHECK POWER SUPPLY FOR FAN CONTROL AMP.
1. Turn ignition switch ON.
2. Check voltage between fan control amp. harness connector
M86 terminal 3 and ground.
OK or NG
OK >> GO TO 5.
NG >> Repair harness or connector.1 – Ground : Battery voltage
RJIA2860E
47 – Ground : Battery voltage.
RJIA3266E
Terminals
Condition Voltage (+)
(−)
Fan control
amp. connectorTe r m i n a l N o .
M86 3 GroundFan speed: 1st
speedApprox. 8 V
RJIA2862E
Page 454 of 3502

ATC-76
TROUBLE DIAGNOSIS
5. CHECK GROUND CIRCUIT FOR FAN CONTROL AMP.
1. Turn ignition switch OFF.
2. Disconnect fan control amp. connector.
3. Check continuity between fan control amp. harness connector
M86 terminal 1 and ground.
OK or NG
OK >> GO TO 6.
NG >> Repair harness or connector.
6. CHECK FOR UNIFIED METER AND A/C AMP. OUTPUT SIGNAL
1. Reconnect fan control amp. connector.
2. Turn ignition switch ON.
3. Check voltage between fan control amp. harness connector
M86 terminal 2 and ground.
OK or NG
OK >> GO TO 9.
NG >>
If the voltage is lower than 2.5 V: GO TO 7.
If the voltage is higher than 10.5 V: GO TO 8.
7. CHECK CIRCUIT CONTINUITY BETWEEN UNIFIED METER AND A/C AMP. AND FAN CONTROL
AMP.
1. Turn ignition switch OFF.
2. Disconnect unified meter and A/C amp. connector and fan con-
trol amp. connector.
3. Check continuity between unified meter and A/C amp. harness
connector M45 terminal 60 and fan control amp. harness con-
nector M86 terminal 2.
OK or NG
OK >> Replace fan control amp.
NG >> Repair harness or connector.1 – Ground : Continuity should exist.
RJIA2863E
Terminals
Condition Voltage (+) (−)
Fan control
amp. connectorTerminal No.
M86 2 GroundFan speed: 1st -
4th speedApprox. 2.5 -
3.5 V
Fan speed: 5th
speedApprox. 9.5 -
10.5 V
RJIA2864E
60 – 2 : Continuity should exist.
RJIA3267E
Page 455 of 3502

TROUBLE DIAGNOSIS
ATC-77
C
D
E
F
G
H
I
K
L
MA
B
AT C
8. CHECK FAN CONTROL AMP.
1. Turn ignition switch OFF.
2. Disconnect fan control amp. connector.
3. Check continuity between fan control amp. connector M86 ter-
minal 2 and 1.
OK or NG
OK >> GO TO 9.
NG >> Replace fan control amp.
9. CHECK CIRCUIT CONTINUITY BETWEEN UNIFIED METER AND A/C AMP. AND FAN CONTROL
AMP.
1. Turn ignition switch OFF.
2. Disconnect unified meter and A/C amp. connector.
3. Check continuity between unified meter and A/C amp. harness
connector M45 terminal 47 and fan control amp. harness con-
nector M86 terminal 3.
OK or NG
OK >> Replace unified meter and A/C amp.
NG >> Repair harness or connector.
COMPONENT INSPECTION
Blower Motor
Confirm smooth rotation of the blower motor.
Ensure that there are no foreign particles inside the blower unit.2 – 1 : Continuity should exist.
SJIA0476E
47 – 3 : Continuity should exist.
RJIA3268E
RJIA3269E
Page 458 of 3502

ATC-80
TROUBLE DIAGNOSIS
3. CHECK CIRCUIT CONTINUITY BETWEEN IPDM E/R AND COMPRESSOR
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R connector and compressor connector.
3. Check continuity between IPDM E/R harness connector E8 ter-
minal 33 and compressor harness connector F2 terminal 1.
OK or NG
OK >> GO TO 4.
NG >> Repair harness or connector.
4. CHECK MAGNET CLUTCH CIRCUIT
Check for operation sound when applying battery voltage direct cur-
rent to terminal.
OK or NG
OK >> 1. Replace IPDM E/R.
2. Go to self-diagnosis procedure AT C - 4 7 , "
FUNCTION
CONFIRMATION PROCEDURE" and perform self-
diagnosis STEP-4. Confirm that magnet clutch opera-
tion normal.
NG >> 1. Replace compressor. Refer to ATC-134, "
Removal
and Installation of Compressor" .
2. Go to self-diagnosis procedure AT C - 4 7 , "
FUNCTION
CONFIRMATION PROCEDURE" and perform self-diagnosis STEP-4. Confirm that magnet
clutch operation normal.
5. CHECK BCM INPUT (COMPRESSOR ON) SIGNAL
Check compressor ON/OFF signal. Refer to AT C - 3 4 , "
CONSULT-II
Function (BCM)" .
OK or NG
OK >> GO TO 8.
NG >> GO TO 6.
6. CHECK CIRCUIT CONTINUITY BETWEEN BCM AND UNIFIED METER AND A/C AMP.
1. Turn ignition switch OFF.
2. Disconnect BCM connector and unified meter and A/C amp.
connector.
3. Check continuity between BCM harness connector M3 terminal
27 and unified meter and A/C amp. harness connector M45 ter-
minal 42.
OK or NG
OK >> GO TO 7.
NG >> Repair harness or connector.33 – 1 : Continuity should exist.
RJIA2004E
RJIA2005E
A/C SW ON : AIR COND SW ON
A/C SW OFF : AIR COND SW OFF
R J I A 1111 E
27 – 42 : Continuity should exist.
RJIA2006E
Page 459 of 3502

TROUBLE DIAGNOSIS
ATC-81
C
D
E
F
G
H
I
K
L
MA
B
AT C
7. CHECK VOLTAGE FOR UNIFIED METER AND A/C AMP. (COMPRESSOR ON SIGNAL)
1. Reconnect BCM connector and unified meter and A/C amp.
connector.
2. Turn ignition switch ON.
3. Check voltage between unified meter and A/C amp. harness
connector M45 terminal 42 and ground.
OK or NG
OK >> GO TO 8.
NG-1 >> If the voltage is approx. 5 V when A/C switch is ON: Replace unified meter and A/C amp.
NG-2 >> If the voltage is approx. 0 V when A/C switch is OFF: Replace BCM.
8. CHECK REFRIGERANT PRESSURE SENSOR
WITH CONSULT-II
1. Start the engine.
2. Check voltage of refrigerant pressure sensor. Refer to EC-90,
"CONSULT-II Reference Value in Data Monitor Mode" (QR
engine) or EC-434, "
CONSULT-II Reference Value in Data Mon-
itor Mode" (VQ engine).
WITHOUT CONSULT-II
1. Start the engine.
2. Check voltage between ECM harness connector F101 terminal
70 and ground.
OK or NG
OK >>WITH CONSULT-II: GO TO 9.
WITHOUT CONSULT-II: GO TO 10.
NG >> Refer to EC-339, "
REFRIGERANT PRESSURE SENSOR" (QR engine) or EC-748, "REFRIGER-
ANT PRESSURE SENSOR" (VQ engine).
Te r m i n a l s
Condition Voltage (+)
(-) Unified meter
and A/C amp.
connectorTerminal
No.
M45 42 GroundA/C switch: ON
(Blower motor oper-
ates.)Approx. 0 V
OFF switch: ON (A/C
System: OFF)Approx. 5 V
RJIA2007E
Terminals
Condition Voltage (+)
(-)
ECM con-
nectorTerminal No.
F10169 (QR engine)
GroundA/C switch: ON
(Blower motor
operates.)Approx. 1.0 - 4.0 V
70 (VQ engine)
SJIA1723E
Page 460 of 3502

ATC-82
TROUBLE DIAGNOSIS
9. CHECK BCM INPUT (FAN ON) SIGNAL
Check FAN ON/OFF signal. Refer to AT C - 3 4 , "
CONSULT-II Function
(BCM)" .
OK or NG
OK >> GO TO 12.
NG >> GO TO 10.
10. CHECK CIRCUIT CONTINUITY BETWEEN BCM AND UNIFIED METER AND A/C AMP.
1. Turn ignition switch OFF.
2. Disconnect BCM connector and unified meter and A/C amp.
connector.
3. Check continuity between BCM harness connector M3 terminal
28 and unified meter and A/C amp. harness connector M45 ter-
minal 57.
OK or NG
OK >> GO TO 11.
NG >> Repair harness or connector.
11 . CHECK VOLTAGE FOR UNIFIED METER AND A/C AMP. (FAN ON SIGNAL)
1. Reconnect BCM connector and unified meter and A/C amp.
connector.
2. Turn ignition switch ON.
3. Check voltage between unified meter and A/C amp. harness
connector M45 terminal 57 and ground.
OK or NG
OK >> GO TO 12.
NG-1 >> If the voltage is approx. 5 V when blower motor is ON: Replace unified meter and A/C amp.
NG-2 >> If the voltage is approx. 0 V when blower motor is OFF: Replace BCM.FAN CONTROL SW ON : FAN ON SIG ON
FAN CONTROL SW OFF : FAN ON SIG OFF
R J I A 1111 E
28 – 57 : Continuity should exist.
RJIA2009E
Terminals
Condition Voltage (+)
(-) Unified meter
and A/C amp.
connectorTerminal No.
M45 57 GroundAUTO switch: ON
(Blower motor
operates.)Approx. 0 V
OFF switch: ON
(A/C system: OFF)Approx. 5 V
RJIA2010E